SEC_APPLY_POLLTIME configuration parameter
Use the SEC_APPLY_POLLTIME configuration parameter to control how long log replay thread should poll for new work before yielding.
- onconfig.std value
-
SEC_APPLY_POLLTIME 0
- values
-
- Minimum value: (Default) 0
- Recommended value for smaller systems (between 1 to 8 CPUVPs): 0
- Recommended value for medium systems (between 8 and 16 CPUVPS): 10
- Recommended value for larger systems (> 16 CPUVPS): 1000
- Maximum value: 5000
- units
-
micro seconds.
- takes effect
-
After you edit your onconfig file and restart the database server.
Usage
In micro seconds, controls how long log replay thread should poll for new work before yielding. Use this parameter to reduce thread context switch overhead while replaying log records. It is recommended to configure poll threads to run on NET VP if SEC_APPLY_POLLTIME value > 0. For more information see, NETTYPE configuration parameter.