RSS_FLOW_CONTROL configuration parameter
Specifies when flow control occurs in a high-availability cluster that contains at least one remote standalone (RS) secondary server.
- onconfig.std value
- RSS_FLOW_CONTROL 0
- values
0
= Flow control is activated when the difference between the current log position and the most recent acknowledged log exceeds 12 times the size of the log buffer.-1
= Flow control is disabled. Disabling flow control might lead to wrapping of the log files and the loss of data.start_value,end_value
= The start_value and end_value determine the amount of lag between the current log position and the last acknowledged log page. The start_value must be greater than the end_value. Values must include one of the following units:K
(Kilobytes)M
(Megabytes)G
(Gigabytes)
RSS_FLOW_CONTROL 128M,100M
starts flow control when the lag between the logs is 128 MB, and stops flow control when the lag drops to 100 MB.- takes effect
- After you edit your onconfig file and restart the database server.
Usage
Flow control provides a way to limit log activity on the primary server so that RS secondary servers in the cluster do not fall too far behind on processing transactions. Enabling flow control ensures that logs on RS secondary servers remain current if the servers are on a busy or intermittent network. When flow control is enabled, and when the difference in log size between the current log position and the last acknowledged log page exceeds thestart_value, then log activity on the primary server becomes restricted. Users connected to the primary server may experience slower response time when flow control is active. Flow control is started when the lag between the logs is greater than the start_value and stops flow control when the log lag has dropped to thestop_value.
You set the RSS_FLOW_CONTROL configuration parameter on the primary server only. All RS secondary servers in the cluster are affected by the RSS_FLOW_CONTROL configuration parameter. Logs are always sent to the RS secondary server in the order in which they were received.
To check if flow control is active for a RS secondary server, use the onstat -g rss verbose command, and compare the RSS flow control value to the Approximate Log Page Backlog value. If the Approximate Log Page Backlog is higher than the first value of RSS flow control, flow control is active. If the Approximate Log Page Backlog is lower than the second value of RSS flow control, flow control is disabled.