MSG_DATE configuration parameter

Use the MSG_DATE configuration parameter to enable the insertion of a date in MM/DD/YY format at the beginning of each message printed to the online log.

onconfig.std value
Not in the onconfig.std file.
values
0 = OFF (the default)

1 = ON

takes effect
After you edit your onconfig file and restart the database server.
When you reset the value dynamically in your onconfig file by running the onmode -wf command.
When you reset the value in memory by running the onmode -wm command.

Usage

In the following example MSG_DATE is set to 1 (ON).
04/10/11 10:26:06  Value of MSG_DATE has been changed to 1.
04/10/11 10:27:35  Value of MSG_DATE has been changed to 1.