STORAGE_FULL_ALARM configuration parameter
Use the STORAGE_FULL_ALARM configuration parameter to configure the frequency and severity of messages and alarms when storage spaces become full.
- onconfig.std value
- STORAGE_FULL_ALARM 600,3
- values
- seconds =
0
(off) or a positive integer indicating the number of seconds between notifications.severity_level =
0
(no alarms) or 1 - 5 - units
- seconds,severity_level
- takes effect
- After you edit your onconfig file and restart the database server.
Usage
When a storage space, such as a dbspace,
sbspace, blobspace, or tblspace, or a partition becomes full, an alarm
is raised and a message is sent to the online message log. You can
specify the number of seconds between notifications with the first
value of this parameter. You can specify the lowest severity for event
alarms to be returned. Setting a specific severity prevents events
that have a lower severity from being raised. But events that have
the same or greater severity as the severity specified are raised.
You can prevent alarms when storage spaces become full by setting
this parameter to 0
.
Regardless of the value of STORAGE_FULL_ALARM, messages are sent to the online message log when storage spaces or partitions become full.