SNA only connection

Controller and tracker in same address space with tracker connected through SNA shows a JES2 with two images. In Image 1, the controller and tracker are in the same address space. Image 2 contains a tracker. The spool is not shared. Two Data Stores are required, one for Image 1 and one for Image 2. All connections are VTAM® links.

Figure 1. Controller and tracker in same address space with tracker connected through SNA

The graphic shows a controller and tracker in the same address space with the tracker connected through SNA.
Key:
FCC
Data Store Communication task
FL
Fetch Job Log Task
FN
Data Store SNA handler task
NCF
Network Communication function

Example members for Figure 7 shows the initialization statements you can use to create the configuration in Controller and tracker in same address space with tracker connected through SNA.

Table 1. Example members for Figure 7
  Controller member Tracker member
C1
OPCOPTS
 RCLEANUP(YES)
 NCFTASK(YES)
 NCFAPPL(LU00C1T)

FLOPTS
 CTLLUNAM(LU00C1D)
 SNADEST(********.LU000D1,
             LU000T1.LU000D2)

ROUTOPTS SNA(LU000T1)
T1
OPCOPTS
 NCFTASK(YES)
 NCFAPPL (LU000T1)

TRROPTS
 HOSTCON(SNA)
 SNAHOST(LU00C1T)
        
D1
DSTOPTS 
 DSTLUNAM(LU000D1)
 CTLLUNAM(LU00C1D)
D2
DSTOPTS 
 HOSTCON(SNA)
  DSTLUNAM(LU000D2)
  CTLLUNAM(LU00C1D)
 Data Store members

Note: In this example, the LU names for the communication partners are the following:
LU00C1D
Controller C1, when communicating with a Data Store.
LU000D1
Data Store D1.
LU000D2
Data Store D2.
LU00C1T
Controller C1, when communicating with tracker T1.
LU000T1