Error message ‘Not able to reach the
component’ appears
Modules Impacted
Data collector, Recommendation, iParse, Generic, RBA,
Release
Probable Root Cause
‘CollectIncidents’ job is enabled,
and status of job is Failed – Issue with Data Collector
Service
Figure 1. Error Message “Not Able to Reach the Component”Figure 2. Error message ‘Not able to reach the component’ (cont.)
Resolution Steps:
Open the job log for CollectIncidents job. If
the job log reads ‘Not able to reach the
component’, check the status of DataCollector
service by performing the following steps:
Press Win+R and type services.msc. Figure 3. Error message ‘Not able to reach the component’ (cont.)
Click OK to open Windows
Services.
Figure 4. Error message ‘Not able to reach the component’ (cont.)
Search for HCL.iAutomate.DC.
Right-click HCL.iAutomate.DC service and click
on Properties.
Figure 5. Error message ‘Not able to reach the component’ (cont.)
Copy the value mentioned in Path to executable
as shown in the image below.
Figure 6. Error message ‘Not able to reach the component’ (cont.)
Open File Explorer, then paste the
copied path and press Enter to
open the desired folder.
Search for
HCL.iAutomate.DataCollector.Service.Host.exe
config file and open it in Notepad.
Figure 7. Error Message ‘Not able to reach the component’ (cont.)
Search for key ServiceHostURL. The value
corresponding to this key is the heartbeat URL. Copy it and paste
it in browser.
If the flowing page appears, it implies that either service is
not running or there is some issue with datacollector.
Figure 8. Error message ‘Not able to reach the component’ (cont.)
If the following WSDL loads successfully, it implies that
service is running fine.