EQQA610 - EQQA709

EQQA610E

AN ERROR OCCURRED WHILE TRANSFERRING DATA WITH CROSS MEMORY.

An error occurred while transferring data with cross memory.

The system rejects the action.

Search the IBM Software database for a solution at Support.

EQQA611E

THE STOW OF A JCL MEMBER IN A JOB LIBRARY FAILED.

The STOW of a JCL member in a job library failed.

The system rejects the action.

Search the IBM Software database for a solution at Support.

EQQA612E

THE WRITE OF A JCL MEMBER IN A JOB LIBRARY FAILED.

The WRITE of a JCL member in a job library failed.

The system rejects the action.

Search the IBM Software database for a solution at Support.

EQQA613E

THE REQUEST FAILED BECAUSE THE JCL PROVIDED IS EMPTY.

The request failed because the JCL provided is empty.

None.

Ensure that the JCL has content.

EQQA614E

THE REQUEST FAILED BECAUSE THE JCL HAS INVALID RECORD LENGTH.

The request failed because the JCL has invalid record length.

None.

Search the IBM Software database for a solution at Support.

EQQA615E

THE INSERT OF A JCL FAILED BECAUSE THE MEMBER ALREADY EXISTS.

The INSERT of a JCL failed because the member already exists.

None.

You cannot have more than one JCL with the same name.

EQQA616E

THE DELETE OF A JCL FAILED BECAUSE THE MEMBER WAS NOT FOUND.

The DELETE of a JCL failed because the member was not found.

None.

Verify the name of the JCL that you want to delete and enter the name of an existing JCL.

EQQA617E

THE JFCB MACRO FAILED TO RETRIEVE THE JOBLIB DATASET LIST.

The JFCB macro failed to retrieve the JOBLIB dataset list.

None.

Search the IBM Software database for a solution at Support.

EQQA618E

THE DESERV MACRO FAILED TO RETRIEVE THE JOBLIB MEMBER LIST.

The DESERV macro failed to retrieve the JOBLIB member list.

None.

Search the IBM Software database for a solution at Support.

EQQA619E

THE LIST FILTER PROVIDED IS NOT VALID.

The list filter provided is not valid.

The request is rejected.

Enter a valid filter.

EQQA620E

AN UNKNOWN ERROR OCCURRED WHILE EXECUTING AN HTTP REQUEST.

An unknown error occurred while executing an HTTP request.

The request is rejected.

Search the IBM Software database for a solution at Support.

EQQA621E

AN HTTP SELECT REQUEST WAS RECEIVED WITH NO INPUT DATA.

An HTTP SELECT request was received with no input data.

The request is rejected.

Search the IBM Software database for a solution at Support.

EQQA622E

THE RETRIEVE OF THE HTTP SELECT INPUT SEGMENT FAILED.

The retrieve of the HTTP SELECT input segment failed. A possible cause for this failure is that the input segment version is old.

The request is rejected.

Check that the z/OS connector is at the proper level. If you recently upgraded z/OS connector, run Settings->Manage Engines->Test Connection in the Dynamic Workload console, to refresh its cached settings, and retry your request.

If this is not the problem, search the IBM Software database for a solution at Support.

EQQA623E

THE HTTP SELECT REQUEST DESTINATION HAS AN INVALID METHOD.

The HTTP SELECT request destination has an invalid method.

The request is rejected.

Specify a valid workstation (either HTTP or HTTPS).

EQQA624E

THE HTTP SELECT REQUEST DESTINATION WAS NOT FOUND.

The HTTP SELECT request destination was not found.

The request is rejected.

Specify an existing destination.

EQQA625E

THE HTTP SELECT REQUEST HAS AN INVALID HTTP DESTINATION TYPE.

The HTTP SELECT request has an invalid HTTP destination type.

The request is rejected.

Specify a destination with a valid HTTP destination type (either broker or agent).

EQQA626E

THE ATTACH OF THE C PROCESS FAILED.

The ATTACH of the C process failed.

The system rejects the action.

Search the IBM Software database for a solution at Support.

EQQA627E

THE REQUEST TO THE DYNAMIC DOMAIN MANAGER FAILED WITH REASON CODE XSSRC.

The request to the Dynamic Domain Manager failed with reason code XSSRC. See Reason codes for a description of the reason code.

The request is rejected.

Correct the error and retry the operation.

EQQA628E

THE HTTP REQUEST FAILED WITH REASON CODE XSSRC.

The HTTP request failed with reason code XSSRC. See Reason codes for a description of the reason code.

The request is rejected.

Correct the error and retry the operation.

EQQA629E

THE C PROCESS FAILED WITH REASON CODE XSSRC.

The C process failed with reason code XSSRC. See Reason codes for a description of the reason code.

The action is rejected.

Correct the error and retry the operation.

EQQA630E

AN ERROR OCCURRED WHILE TRANSFERRING DATA WITH CROSS MEMORY.

An error occurred while transferring data with cross memory.

The system rejects the action.

Search the IBM Support database for a solution at Support.

EQQA631E

THE STORAGE NEEDED TO PROCESS THE REQUEST WAS NOT AVAILABLE.

The storage needed to process the request was not available.

The action is rejected.

Search the IBM Support database for a solution at Support.

EQQA632E

THE TEMPLATE YOU HAVE ENTERED IS NOT CORRECT.

The template you have entered is not correct.

The request is rejected.

Specify a valid template.

EQQA634E

THE FUNCTION REQUESTED IS UNKNOWN.

The function requested is unknown.

The request is rejected.

Search the IBM Support database for a solution at Support.

EQQA635E

AN UNKNOWN ERROR OCCURRED WHILE EXECUTING A DEST REQUEST.

An unknown error occurred while executing a DEST request.

The system rejects the request.

Search the IBM Support database for a solution at Support.

EQQA636E

THE NAME OF THE MEMBER CONTAINS AN INVALID CHARACTER.

The name of the member contains an invalid character.

The system rejects the request.

Specify an existing member name.

EQQA637E

THE NAME OF THE DATA SET IS INVALID.

The name of the data set is invalid.

The system rejects the request.

Specify an existing data set name.

EQQA638E

THE DELETE POOL HTTP REQUEST FAILED WITH REASON CODE XSSRC.

The delete pool HTTP request failed with reason code XSSRC. See Reason codes for a description of the reason code.

The request is rejected.

Correct the error and retry the operation.

EQQA639E

THE DELETE POOL HTTP REQUEST FAILED WITH REASON CODE &XSSRC

The HTTP request has failed. See Reason codes for a description of the reason code.

The request is rejected.

Correct the error and retry the operation.

EQQA640E

THE REQUEST CANNOT BE EXECUTED ON A BROKER DYNAMIC WORKSTATION.

The operation type you requested is not supported on broker workstations. You can perform this operation on the following workstation types:
  • Pool
  • Dynamic pool
  • HCL Workload Automation for Z agent

The request is rejected.

Specify one of the workstation types where you can perform the operation. See Managing the Workload or the Dynamic Workload Console User's Guide for details.

EQQA641E

THE POOL CREATION FAILED. THE NAME CONTAINS UNSUPPORTED SPECIAL CHARACTERS.

The pool creation failed. The name contains unsupported special characters.

The request is rejected.

Correct the error and retry the operation.

EQQA642E

THE HTTP REQUEST FAILED. THE SPECIFIED WORKSTATION WAS NOT FOUND.

The HTTP request failed. The specified workstation was not found.

The request is rejected.

Correct the error and retry the operation.

EQQA643E

THE HTTP REQUEST CANNOT BE EXECUTED. THE JOB WAS NOT FOUND.

The HTTP request cannot be executed. The job was not found.

The request is rejected.

Correct the error and retry the operation.

EQQA644E

THE JOB CANNOT BE RESTARTED BECAUSE OF A DEPENDENCY WITH ANOTHER JOB.

The job cannot be rerun, restarted, or refreshed because it is a predecessor job to another external job or because a conditional dependency is defined.

The request is rejected.

Submit another occurrence of the predecessor job without the dependency.

EQQA645E

HTTP REQUEST COULD NOT BE FULFILLED.

An HTTP request was made by the controller to the agent or broker, but the request could not be fulfilled. A possible cause for this problem is that the version of the agent or dynamic workload broker might not be compatible with the request.

The request is rejected.

Verify the version of the agent or dynamic workload broker to ensure it is compatible with the request and then submit the request again.

EQQA700E

Is mandatory must be C, P or N.

In the Application Description ISPF dialogue the user entered a wrong value in the Is mandatory field. This field specifies if an external dependency must be resolved immediately (at plan level), later (after waiting for a subsequent predecessor add) or if it can be left unresolved. Allowed values are C (control), P (plan), or N (no).

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA701E

Criteria must be C, S, R or A.

In the Application Description ISPF dialogue the user entered a wrong value in the Criteria field. This field specifies how to resolve a dependency. Allowed values are C (Closest Preceding criteria), S (Same Day criteria), R (Relative Interval criteria), or A (Absolute interval criteria).

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA702E

From hours must be blank or numeric: range is 0-167.

In the Application Description ISPF dialogue the user entered a wrong value in the From hours field. This field is related to the resolution criteria used to resolve the dependency: it specifies the number of hours before of after the Input Arrival time (as specified in the when field) at which the interval must start.

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA703E

From minutes must be blank or numeric: range is 0-59.

In the Application Description ISPF dialogue the user entered a wrong value in the From minutes field. This field is related to the resolution criteria used to resolve the dependency: it specifies the number of minutes before of after the Input Arrival time (as specified in the when field) at which the interval must start

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA704E

For days must be numeric: range is 0-7

In the Application Description ISPF dialogue the user entered a wrong value in the For days field. This field is related to the resolution criteria used to resolve the dependency: it specifies the number of days one can move back or forward to solve the dependency.

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA705E

To hours must be numeric: range is 0-167

In theApplication Description ISPF dialogue the user entered a wrong value in the To hours field. This field is related to the resolution criteria used to resolve the dependency: it specifies the number of hours before of after the Input Arrival time (as specified in the when field) at which the interval must end.

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA706E

To minutes must be numeric: range is 0-59

In the Application Description ISPF dialogue the user entered a wrong value in the To minutes field. This field is related to the resolution criteria used to resolve the dependency: it specifies the number of minutes before or after the Input Arrival time (as specified in the when field) at which the interval must end.

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA707E

Time format must be HH.MM

In the Application Description ISPF dialogue the user entered a wrong value in the Time field. This field is related to the resolution criteria used to resolve the dependency: it specifies the time before of after the Input Arrival time (as specified in the when field) at which the interval must end/start.

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA708E

when must be B or A.

In the Application Description ISPF dialogue the user entered a wrong value in the when field. This field is related to the resolution criteria used to resolve the dependency: it can refer to the start or end of the interval where the dependency must be solved and specify if one must search before (B) of after (A) the IA of the occurrence to be added.

The ISPF panel is displayed again.

Enter a valid value in the field.

EQQA709E

from fields must be all blank or all filled up.

In the Application Description ISPF dialogue the user entered values in only a few of the required From fields. These fields are related to the resolution criteria used to resolve the dependency and can be all left blank to indicate that there is no limit in searching a match in the past before the IA of the occurrence to be added. But it is not allowed to enter values in some of these fields while leaving others blank.

The ISPF panel is displayed again.

Either enter a valid value in every From field of the panel or leave them all blank.