EQQA000 - EQQA609
EQQA000E
YOU ARE NOT AUTHORIZED TO ACCESS THE AD DATABASE
You have attempted to access the application description (AD) database, but you are not authorized to access it. Or, you do not have access authority to a minimum of one of the following HCL Workload Automation for Z resources that are used together with the AD database: the calendar database, the workstation description database, or in some cases, the long-term plan data set.
The request is rejected.
If you require access, contact your security administrator.
EQQA002E
THIS VERSION OF THE APPLICATION ALREADY EXISTS
The application already exists with the valid-from date that you specified.
The system waits for you to respond.
Specify another valid-from date.
EQQA003E
SELECTED PREDECESSOR IS NOT EXTERNAL
The predecessor you selected is not external. When defining an external dependency, you must specify the application ID of the external predecessor before selecting to describe it.
The system waits for you to respond.
Specify the application ID of the external predecessor.
EQQA004E
NO MATCHING APPLICATION DESCRIPTION(S) FOUND
No application description matched the generic or nongeneric search criteria you specified to generate a list of applications.
The system waits for you to respond.
Retry using new selection criteria.
EQQA005E
NO MATCHING APPLICATION DESCRIPTION FOUND
You selected an application that does not have a matching application description. In a list of applications, in either the browse or list function, the application you selected was not found. The application may have been deleted or modified after the list of application entries was generated.
The request is rejected.
Return to the application selection criteria panel and press ENTER to generate a fresh list of applications.
EQQA006I
NO RUNCYCLES FOUND FOR THIS APPLICATION
You have attempted to display the run cycles of an application for which no run cycles have been specified.
The request is rejected.
None.
EQQA009I
NO PREDECESSORS FOUND FOR THIS OPERATION
You have attempted to display the predecessors of an operation for which no predecessors have been specified.
The request is rejected.
None.
EQQA010E
INVALID PARAMETER INPUT TO MODULE MOD
This message indicates a programming error.
The system waits for you to respond.
To collect appropriate documentation for problem determination, see the Diagnosis Guide and Reference manual, Chapter 3. Problem analysis procedures, section, "Information needed for all problems", sub-section, "Information to collect for application description problems". If you cannot determine the cause of the error and the error persists, search the IBM Support database for a solution at Support.
Contact your system programmer.
EQQA011I
THE APPLICATION IS CREATED
The application has been created and saved in the application description database.
None.
None.
EQQA012I
THE SELECTED APPLICATION IS MODIFIED
The selected application has been modified and saved in the application description database.
None.
None.
EQQA013I
THE SELECTED APPLICATION IS COPIED
The selected application has been copied and the copy has been saved in the application description database.
None.
None.
EQQA014I
THE SELECTED APPLICATION IS DELETED
The selected application has been deleted from the application description database.
None.
None.
EQQA015E
THE NUMBER OF INTERNAL PREDECESSORS IS TOO LARGE
You specified too many internal predecessors.
The system waits for you to respond.
Delete one or more internal predecessors.
EQQA016E
THE NUMBER OF EXTERNAL PREDECESSORS IS TOO LARGE
You specified too many external predecessors.
The system waits for you to respond.
Delete one or more external predecessors.
EQQA017E
THE NUMBER OF SPECIAL RESOURCES IS TOO LARGE
You specified too many special resources.
The system waits for you to respond.
Delete one or more special resources.
EQQA018E
OP OP HAS AN EXTERNAL PRED WS EWS, WHICH IS NOT FOUND
Operation OP has an external predecessor workstation (EWS) that does not exist in the workstation description database.
The system waits for you to respond.
Enter correct data.
EQQA019E
THE NUMBER OF CONDITIONAL DEPENDENCIES IS TOO LARGE
You specified too many conditional dependencies.
The system waits for you to respond.
Delete one or more conditional dependencies.
EQQA021I
NO SPECIAL RESOURCES FOUND FOR THIS OPERATION
You have attempted to display the special resources of an operation for which no special resources have been defined.
None.
None.
EQQA022E
THE APPLICATION STATUS SPECIFIED IS NOT VALID
- A
- For active
- P
- For pending
- blank
- For both active and pending
None.
Specify a correct value and press Enter.
EQQA023E
PRIORITY MUST BE A NUMBER FROM 1 - 9
See text.
None.
Specify a correct value and press Enter.
EQQA024E
STATUS MUST BE OCHCACT OR OCHCPEND
See text.
None.
Specify a correct value and press Enter.
EQQA025E
INPUT DATA IN FIELD IS REQUIRED
See text.
None.
Specify a correct value and press Enter.
EQQA026E
AUTOMATION NOT VALID
The Automation option can be Y (yes), N (no), or blank.
EQQA027I
NO CONDITION FOUND FOR THIS OPERATION
The selected operation has no conditional dependency, therefore the condition list is empty.
EQQA028E
CONDITION RULE MUST BE SELECTED AS OCHCYES OR OCHCNO
The condition rule option can be Y (yes) or N (no).
EQQA029E
ONE AND ONLY ONE CONDITION RULE MUST BE SELECTED
You entered the same option in both the condition rule fields.
The system waits for you to respond.
According to the boolean logic, the first field corresponds to the OR operator, the second one to the AND operator. Decide which criteria you want to apply and deselect the other one.
EQQA101E
THE VARIABLE TABLE NAME CONTAINS AN INVALID CHARACTER
The name of a variable table contains 1 to 16 alphanumeric characters, where the first character is alphabetic.
None.
Specify a correct value and press Enter.
EQQA102E
AN APPLICATION WITH THIS ID ALREADY EXISTS
You have attempted to create an application, but the application ID that you specified already exists in the application description database.
The system waits for you to respond.
Enter a unique application ID. If you want to create versions of an already existing application, you should use the copy function.
EQQA103E
THE APPLICATION IS BEING UPDATED BY USER USR TRY LATER
Another user is currently updating the application you want to update.
The system waits for you to respond.
Try to update the application later.
EQQA104E
THE PERIOD NAME DOES NOT EXIST IN THE CALENDAR
The period name that you specified is not defined in the calendar database.
The system waits for you to respond.
Enter an existing period name, or use the Calendar dialog to define the period name.
EQQA105E
YOU ARE NOT AUTHORIZED TO READ THE JCL VARIABLE TABLE DATA BASE
You have attempted to refer to a JCL variable table. To do this, you need read authority to the JCL variable table database.
The system waits for you to respond.
If you need to refer to JCL variable table names, contact your security administrator.
EQQA106E
DEADLINE PRECEDES INPUT ARRIVAL TIME
The deadline must be later than the input arrival time.
None.
Specify a correct value and press Enter.
EQQA107E
WORKSTATION DOES NOT EXIST IN WS DESCRIPTION DATA BASE
The workstation name that you specified is not defined in the workstation description database.
The system waits for you to respond.
Enter an existing workstation name or use the Work Station Description dialog to define the workstation name.
EQQA108W
WHEN UPDATING WS NAME, OPR, EXT, INT, CND ITEMS MUST ALL BE SELECTED
- CND
- Conditional predecessor ws name
- OPR
- Workstation name
- INT
- Predecessor ws name
- EXT
- Predecessor ws name
This does not prevent you from updating only one of the items.
The system waits for you to continue.
Select all three items.
EQQA109I
NO USER FIELDS ARE FOUND FOR THE OPERATION
You have attempted to display the user fields of an operation for which no predecessors have been specified.
The request is rejected.
None.
EQQA110E
JOBNAME REQUIRED FOR JOB SETUP, PRINT, OR COMPUTER WS
A job name is required for an operation at a job setup, print, or computer workstation.
None.
Specify a correct value and press Enter.
EQQA111E
YOU HAVE ENTERED AN INVALID VALUE IN ONE OF THE WLM FIELDS
- L
- Long Duration. The job is assisted if it runs beyond its estimated duration.
- D
- Deadline. The job is assisted if it has not finished when its deadline time is reached.
- S
- Latest Start Time. The job is assisted if it is submitted after its latest start time.
- C
- Conditional. An algorithm calculates whether to apply the Deadline policy or the Latest Start Time policy.
If you do not specify any value for the WLM POLICY field, the value specified in the WLM parameter of the OPCOPTS statement will be used.
Enter a valid value in the WLM POLICY field.
EQQA112E
VARIABLE DURATION AND DEADLINE TABLE CONTAINS DUPLICATED RULE NAME.
In the variable duration and deadline table, the same rule name was specified in more than one line.
Correct the variable duration and deadline table and press Enter.
EQQA113E
INPUT ARRIVAL TIME LATER THAN ONE OR MORE VARIABLE DEADLINES.
The input arrival time specified for the operation is later than one or more variable deadlines specified for the application.
Specify a correct value and press Enter.
EQQA114W
SPECIFIED VARIABLE DEADLINE IS EARLIER THAN APPLICATION INPUT ARRIVAL
The variable deadline that you specified is earlier than the application input arrival time for the application. This does not prevent you from saving the application description as it is.
The variable deadline is accepted and the system waits for you to respond.
Enter END to save the application description or make the variable deadline and input arrival time consistent.
EQQA115E
SPECIFIED VARIABLE DEADLINE IS EARLIER THAN OP INPUT ARRIVAL
The variable deadline time must be later than the input arrival time.
None.
Specify a correct value and press Enter.
EQQA116E
DURATION TIME IS NOT SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA117E
24.00 IS NOT ALLOWED AS INPUT ARRIVAL TIME
Valid input arrival times are 00.00 through 23.59.
None.
Specify a correct value and press Enter.
EQQA118E
00.00 IS NOT ALLOWED AS DEADLINE TIME
Valid deadline times are 00.01 through 24.00.
None.
Specify a correct value and press Enter.
EQQA119W
SPECIFIED OPERATION DEADLINE EARLIER THAN APPLICATION INPUT ARRIVAL
The operation deadline that you specified is earlier than the application input arrival time for the application. This does not prevent you from saving the application description as it is.
The operation deadline is accepted and the system waits for you to respond.
Enter END to save the application description or make the deadline and input arrival time consistent.
EQQA120I
SPECIFIED OPERATION INPUT ARRIVAL LATER THAN APPLICATION DEADLINE
The operation input arrival time that you specified is later than the deadline time for the application. This does not prevent you from saving the application description as it is.
The input arrival time for the operation is accepted and the system waits for you to respond.
Enter END to save the application description or make the operation input arrival and application deadline consistent
EQQA121E
SPECIFIED OPERATION DEADLINE EARLIER THAN OP INPUT ARRIVAL
The deadline time must be later than the input arrival time.
None.
Specify a correct value and press Enter.
EQQA122I
SPECIFIED APPLICATION INPUT ARRIVAL LATER THAN AN OP INPUT ARRIVAL
The application input arrival time that you specified is later than an operation input arrival time defined in the OPER table. This does not prevent you from saving the application description as it is.
The input arrival time for the application is accepted and the system waits for you to respond.
Enter END to save the application description or make the input arrival times consistent.
EQQA123I
SPECIFIED OP INPUT ARRIVAL EARLIER THAN APPLICATION INPUT ARRIVAL
The operation input arrival time that you specified is earlier than the input arrival time for the application. This does not prevent you from saving the application description as it is.
The input arrival time for the operation is accepted and the system waits for you to respond.
Enter END to save the application description or make the input arrival times consistent.
EQQA124I
SPECIFIED OP DEADLINE LATER THAN APPLICATION DEADLINE
The operation deadline time that you specified is later than the deadline time for the application. This does not prevent you from saving the application description as it is.
The deadline time for the operation is accepted. The system waits for you to respond.
Enter END to save the application description or make the deadline times consistent.
EQQA125I
NO APPLICATION INPUT ARRIVAL TIME SPECIFIED YET
No application input arrival time is specified for this application. This does not prevent you from saving the application description as it is.
The times specified for the operation are accepted. The system waits for you to respond.
Enter END to save the application description, or make the deadline times consistent.
EQQA126E
SPECIFY AT LEAST ONE RUNDAY
See text.
None.
Specify a correct value and press Enter.
EQQA127E
OUT-OF-EFFECT-FROM DATE PRECEDES IN-EFFECT-FROM DATE
The out-of-effect-from date for a run cycle must be later than the in-effect-from date.
None.
Specify a correct value and press Enter.
EQQA128W
MULTIPLE INSTANCES DETECTED, BUT IA WAS SPECIFIED AND ITS VALUE WILL BE USED TO GENERATE ONLY ONE OCCURRENCE PER DATE
The rule includes run cycle groups that generate more than one instance per day due to the definition of several IA times. But an Input Arrival time value is specified for the run cycle in the AD panels. This value overruns the IA times defined in the run cycle group and is used to define a single occurrence for each day while the multiple daily instances are ignored.
Generates one occurrence per day with the IA time defined in the AD.
If this is not the expected result, consider revising the run cycle group definition. For run cycle groups of type N, you must delete the IA time to keep the multiple instances.
EQQA129E
THE REFERENCED RUN CYCLE GROUP IS NOT VALID
A problem has been detected in the referenced run cycle group.
None.
Verify the run cycle group or specify a different one.
EQQA132I
IA 2400 IS NOT SUPPORTED, CHANGED TO 0000 THE DAY AFTER
The occurrence input arrival time specified is out of the prearranged range. Valid input arrival times are 00.00 through 23.59. The inout has therefore been converted to 00.00 the day after.
None.
None.
EQQA133I
DEADLINE 0000 IS NOT SUPPORTED,CHANGED TO 2400 THE DAY BEFORE
The occurrence deadline specified is out of the prearranged range. Valid deadline times are 00.01 through 24.00. The deadline has therefore been converted to 24.00 the day before.
None.
None.
EQQA134E
SUPPRESS IF LATE = YES ALLOWED ONLY WHEN TIME DEPENDENT = YES
The SUPPRESS IF LATE option can be YES only when the TIME DEPENDENT option is specified as YES.
None.
Specify a correct value and press Enter.
EQQA135E
THE SMOOTHING FACTOR MUST BE A NUMBER 0 - 999
See text.
None.
Specify a correct value and press Enter.
EQQA136E
THE FEEDBACK LIMIT MUST BE A NUMBER 100 - 999
See text.
None.
Specify a correct value and press Enter.
EQQA137E
DEADLINE WTO IS NOT DEFINED OR INVALID
Valid deadline WTO options are Y for Yes, and N for No.
None.
Specify a correct value and press Enter.
EQQA138W
OPERATION IA OPIA LESS THAN OCCURRENCE IA OCCIA
The operation arrival date is earlier than the occurrence. This is accepted, but might not be what you intend.
None.
None.
EQQA139E
VALID VALUES: P, W, OR N
- P
- Critical path target
- W
- Eligible for WLM assistance
- N
- Not eligible for WLM assistance
Enter a valid value in the CRITICAL field.
EQQA140E
REPEAT EVERY CAN BE A VALUE FROM 00.01 TO 23.59
See text.
None.
Specify a correct value and press Enter.
EQQA141E
EVERY OPTION NOT CONSISTENT WITH INPUT ARRIVAL AND WORK DAY END TIME
The REPEAT END TIME must be a value between the input arrival time of the run cycle and the calendar work day end time of the application.
The panel is redisplayed with this error message.
If you are in the EVERY Options panel, specify a valid value for the REPEAT END TIME. If you are in the Modifying a Rule panel, go to the EVERY Options panel and set a valid value for the REPEAT END TIME.
EQQA142E
REPEAT END TIME CAN BE A VALUE FROM 00.00 TO 23.59
See text.
None.
Specify a correct value and press Enter.
EQQA143E
REPEAT EVERY CANNOT BE BLANK, IF REPEAT END TIME IS SET
See text.
None.
Specify a correct value and press Enter.
EQQA144E
REPEAT END TIME CANNOT BE BLANK, IF REPEAT EVERY IS SET
See text.
None.
Specify a correct value and press Enter.
EQQA145E
THE DEADLINE SMOOTHING FACTOR MUST BE A NUMBER 0 - 999
See text.
None.
Specify a correct value and press Enter.
EQQA146E
THE DEADLINE FEEDBACK LIMIT MUST BE A NUMBER 100 - 999
See text.
None.
Specify a correct value and press Enter.
EQQA147E
DEADLINE ACTION NOT VALID. ALLOWED VALUES ARE: C, N, E, A, BLANK.
- A
- Only an alert message is issued.
- C
- The operation is set to Complete if its status allows it, otherwise it is NOPed.
- E
- The operation is set to Error with ODEA if its status allows it, otherwise it is ignored.
- N
- Operation and all its internal successors are NOPed, if their status allows NOPing. Otherwise it is ignored.
- blank
- No action is taken.
None.
Specify a correct value in the Action field.
EQQA148E
NOT STARTED ACTION NOT VALID. ALLOWED VALUES ARE: C, N, E, A.
- A
- Only an alert message is issued.
- C
- The operation is set to Complete if its status allows it, otherwise it is NOPed.
- E
- The operation is set to Error with OLAT if its status allows it, otherwise it is ignored.
- N
- Operation and all its internal successors are NOPed, if their status allows NOPing. Otherwise it is ignored.
None.
Specify a correct value in the Action field.
EQQA200E
OPERATION NUMBER MUST BE 1 - 255
See text.
None.
Specify a correct value and press Enter.
EQQA201E
THE VARIABLE TABLE IS NOT DEFINED
You have tried to define a variable table ID that does not exist in HCL Workload Automation for Z's database.
None.
Specify a correct value and press Enter.
EQQA202E
THE RUN CYCLE TYPE IS INVALID, ENTER EITHER N, X, R OR E
- N
- Normal offset-based run cycles.
- X
- Negative offset-based run cycles.
- R
- Regular rule-based run cycles.
- E
- Exception rule-based run cycles.
The request is rejected.
Change the run cycle type to one of the supported values.
EQQA203E
THE FREE DAY RULE SPECIFICATION IS INVALID
- E
- Free days excluded.
- 1
- Run on the closest workday before the free day.
- 2
- Run on the closest workday after the free day.
- 3
- Run on the free day.
- 4
- Do not run at all.
EQQA204E
CONDITION RULE SUBSET VALUE MUST BE 0-999
See text.
None.
Specify a correct value and press Enter.
EQQA205E
THE RUN CYCLE TYPE MUST BE SPECIFIED
- N
- Normal offset-based run cycles.
- X
- Negative offset-based run cycles.
- R
- Regular rule-based run cycles.
- E
- Exception rule-based run cycles.
The request is rejected.
Change the run cycle type to one of the supported values.
EQQA206E
THE FREE DAY RULE MUST BE SPECIFIED
- E
- Free days excluded.
- 1
- Run on the closest workday before the free day.
- 2
- Run on the closest workday after the free day.
- 3
- Run on the free day.
- 4
- Do not run at all.
None.
Specify a correct value and press Enter.
EQQA207E
AN IN-EFFECT-FROM DATE MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA208E
AN OUT-OF-EFFECT-FROM DATE MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA209E
THE RUN DAY OFFSET MUST BE A NUMBER FROM -999 TO -1 OR 1 TO 999
See text.
None.
Specify a correct value and press Enter.
EQQA210E
THE PRINT OPTION MUST BE SPECIFIED
See text.
None.
Specify the print option and press Enter.
EQQA211E
THE PRINT OPTION CHARACTER IS INVALID
Valid print option characters are A for always and C for conditionally.
See text.
None.
Specify a correct value and press Enter.
EQQA212E
WHEN TIME DEPENDENT = YES, SUPPRESS IF LATE MUST BE SPECIFIED
The SUPPRESS IF LATE option must be specified when the TIME DEPENDENT option is specified as YES.
None.
Specify a correct value and press Enter.
EQQA213E
THE WS RESOURCE AMOUNT SPECIFIED MUST BE A NUMBER 0 - 99
See text.
None.
Specify a correct value and press Enter.
EQQA214E
THE JOB OPTION CHARACTER SPECIFIED IS INVALID
Valid job option characters are Y for yes and N for no.
None.
Specify a correct value and press Enter.
EQQA215E
THE NUMBER OF PARALLEL SERVERS MUST BE 1 - 99
See text.
None.
Specify a correct value and press Enter.
EQQA216E
THE INPUT ARRIVAL DAY MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA217E
THE INPUT ARRIVAL DAY MUST BE A NUMBER 0 - 99
See text.
None.
Specify a correct value and press Enter.
EQQA218E
THE INPUT ARRIVAL TIME MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA219E
THE NUMBER OF PARALLEL SERVERS MUST BE 1 FOR CPU OPERATIONS
Operations on a computer workstation can use only one parallel server.
The panel is redisplayed and the dialog waits for you to change the number of parallel servers.
Change the number of parallel servers to one.
EQQA220E
THE DEADLINE DAY MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA221E
THE DEADLINE DAY OFFSET SPECIFIED MUST BE A NUMBER 0 - 99
See text.
None.
Specify a correct value and press Enter.
EQQA222E
THE DEADLINE TIME MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA223E
THE JCL EDIT/BROWSE FUNCTION NEEDS A JOBNAME
The JCL edit/browse option can be called only if a jobname has been specified.
The panel is displayed again with this error message.
Specify a jobname.
EQQA224E
AD CAPPL OP COP IS JUST A NORMAL PREDECESSOR
You cannot define the same job as both conditional and normal predecessor.
The request is rejected.
Remove the inconsistency.
EQQA225E
AD PAPPL OP POP IS JUST A CONDITIONAL DEPENDENCY OPERATION
You cannot define the same job as both conditional and normal predecessor.
The request is rejected.
Remove the inconsistency.
EQQA226E
THE OPERATION NUMBER MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA227E
CONDITION DEPENDENCY CANNOT REFER ITSELF AS INTERNAL PRED.
The operation number specified for the conditional predecessor is equal to the owning operation number.
The request is rejected.
Correct the operation number.
EQQA228E
THE SPECIFIED SPECIAL RESOURCE HELD OPTION IS INVALID
Valid special resource held options are S for shared and X for exclusive.
None.
Specify a correct value and press Enter.
EQQA229W
OFFSET WRKOFF IS GREATER THAN PERIOD INTERVAL WRKINT
The number that you specified for a positive or negative run day offset is greater than the period interval value. If the period is type A, no occurrences are created in the long term plan (LTP) for this offset. If the period type is W, the message is issued as a warning but occurrences can still be created in the LTP.
The system waits for you to respond.
Check if the offset value provides the desired run dates. Correct the value if required. If LTP occurrences should be created, and the period type is A, you must change either the period interval value or the run cycle offset value. Press the END key to save the offset values.
EQQA230E
THE VALID RESPONSE IS Y OR N FOLLOWED BY ENTER KEY
Y deletes the application and N cancels the deletion of the application.
None.
Specify a correct value and press Enter.
EQQA231E
A PERIOD NAME MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA232E
UP TO 24 (12 POSITIVE AND 12 NEGATIVE) RUNDAY OFFSETS ARE ALLOWED
See text.
None.
Specify a correct value and press Enter.
EQQA233E
THE SPECIFIED HIGHEST RETURN CODE MUST BE A NUMBER 0 - 4095
See text.
None.
Specify a correct value and press Enter.
EQQA234E
THE APPLICATION ID IS NOT SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQA235E
THE FIRST CHARACTER IN APPLICATION ID MUST BE ALPHABETIC
See text.
None.
Specify a correct value and press Enter.
EQQA236E
THERE IS AN INVALID CHARACTER IN THE APPLICATION ID
An application ID can be made up of the following valid characters: A through Z, 0 through 9, and national characters (that is, #, $, and @).
None.
Specify a correct value and press Enter.
EQQA237E
ENTER THE OWNER ID
See text.
None.
Specify a correct value and press Enter.
EQQA238E
THE PRIORITY MUST BE A NUMBER FROM 1 TO 9
See text.
None.
Specify a correct value and press Enter.
EQQA239E
ENTER THE STATUS, A OR P
A stands for active and P for pending.
None.
Specify a correct value and press Enter.
EQQA240E
SPECIFY A VALID-FROM DATE
See text.
None.
Specify a correct value and press Enter.
EQQA241E
THE MAXIMUM 4 ACTIVE VERSIONS ALREADY EXIST
You have attempted to enter an active version of an application description but the maximum four active versions of the application description already exist in the application description database.
The system waits for you to respond.
Reenter with a new application ID, valid-from data, or status; or delete one of the four active versions.
EQQA242E
THE MAXIMUM 4 PENDING VERSIONS ALREADY EXIST
You have attempted to enter a pending version of an application description but the maximum four pending versions of the application description already exist in the application description database.
The system waits for you to respond.
Reenter with a new application ID, valid-from data, or status; or delete one of the four pending versions.
EQQA243E
A PENDING VERSION CANNOT BE COPIED
You have attempted to copy a pending version of the application description but only an active version can be copied.
The request is rejected and the system waits for you to respond.
Select an active version to copy.
EQQA244E
APPLICATION ID, STATUS, OR VALID-FROM MUST BE CHANGED
In the copy function, one of the three key fields (application ID, status, or valid-from key fields) must be changed to create a new version of an existing application description, or a new application description.
The system waits for you to respond.
Change one of the three key fields.
EQQA245E
THE RUN DAY OFFSET TABLE CONTAINS DUPLICATES
The list of run days cannot contain duplicate offsets.
The system waits for you to respond.
Use the row command D to delete the duplicate run day offsets or change the duplicates.
EQQA246E
SPECIFY A WORK STATION NAME
See text.
None.
Specify a correct value and press Enter.
EQQA247E
THE OPERATION TABLE CONTAINS DUPLICATE OPERATION NUMBERS
The list of operations cannot contain duplicate operation numbers.
The system waits for you to respond.
Use the row command D to delete the duplicate operation numbers or change the duplicates.
EQQA248E
THE PREDECESSOR TABLE CONTAINS DUPLICATE PREDECESSORS
The list of predecessors cannot contain duplicate predecessors.
The system waits for you to respond.
Use the row command D to delete the duplicate predecessors or change the duplicates.
EQQA249E
THE SPECIAL RESOURCE TABLE CONTAINS DUPLICATE RESOURCES
The list of special resources cannot contain duplicate resources.
The system waits for you to respond.
Use the row command D to delete the duplicate resources or change the duplicates.
EQQA250I
AD DOES NOT EXIST IN DATA BASE
The specified external predecessor application does not exist in the application description database. This does not prevent you from saving the application as it is.
The system waits for you to respond.
Either enter END to save the external predecessor application or change the external predecessor application.
EQQA251E
AD DOES NOT EXIST IN DATA BASE, ENTER WS NAME
The specified external predecessor application does not exist in the application description database, so the predecessor workstation name cannot be picked up. Therefore, you must specify the predecessor workstation name.
The system waits for you to respond.
Enter the workstation name of the external predecessor.
EQQA252I
PRED OP DOES NOT EXIST IN PREDECESSOR APPLICATION
The specified external predecessor operation does not exist in the external predecessor application. This does not prevent you from saving the application as it is.
The system waits for you to respond.
Either enter END to save the external predecessor operation or change the external predecessor operation.
EQQA253E
PRED OP DOES NOT EXIST IN PREDECESSOR APPLICATION, ENTER WS NAME
The specified external predecessor operation does not exist in the external predecessor application, so the predecessor workstation name cannot be picked up. Therefore, you must specify the predecessor workstation name.
The system waits for you to respond.
Enter the predecessor workstation name.
EQQA254E
PRINT OPERATION OP MAY HAVE ONLY ONE CPU PREDECESSOR
The print operation number (OP) can have only one CPU internal predecessor.
The system waits for you to respond.
Delete all except one of the internal predecessors.
EQQA255E
JOB SETUP OP OP MUST HAVE THE SAME JOBNAME AS A CPU SUCCESSOR
The job setup operation number (OP) must have the same job name as any of its CPU successors.
The system waits for you to respond.
Enter a valid CPU successor job name.
EQQA256E
PRINT OP OP MUST HAVE THE SAME JOBNAME AS THE CPU PREDECESSOR
The print operation number (OP) must have the same job name as its CPU predecessor.
The system waits for you to respond.
Enter a valid CPU predecessor job name.
EQQA257E
THIS VERSIONS VALID-FROM DATE CAN NOT PRECEDE MSGVALF
The application valid-from date for a previously defined application description version has been modified. The valid-from date now falls within the validity period of another version of this application description.
The system waits for you to respond.
Change the valid-from date so that it is later than the date specified in MSGVALF. Review the validity periods for versions of this application. If a new version is required for the date that you specified, you can copy a version of the application description and specify the required valid-from date.
EQQA258I
AD HAS PENDING STATUS
The specified external predecessor application has pending status. This does not prevent you from saving the application as it is.
The system waits for you to respond.
Enter END to save the external predecessor application as it is, or change it.
EQQA259E
DUPLICATE CONDITIONAL DEPENDENCY
You specified the same conditions details in more than one condition definition.
None.
Specify different conditions and press Enter.
EQQA260E
SAME DATE SPECIFIED FOR IN-EFFECT-FROM AND OUT-OF-EFFECT-FROM
The out-of-effect-from date must be later than the in-effect-from date.
EQQA261E
NO MORE THAN 12 ITEMS CAN BE SPECIFIED
The print function can handle up to 12 print items at a time.
The system waits for you to respond.
Delete print items so that the total does not exceed 12.
EQQA262E
NO MORE THAN 5 ITEMS CAN BE SELECTED
No more than five sort items can be selected to be part of the cross reference list.
The system waits for you to respond.
Delete sort items so that the total is not greater than five.
EQQA263E
THE SORT ORDER SPECIFIED IS NOT A NUMBER 1 - 5
See text.
None.
Specify a correct value and press Enter.
EQQA264E
THE SPECIFIED SORT ORDER CONTAINS DUPLICATE DIGITS
See text.
None.
Specify a correct value and press Enter.
EQQA265E
THE SPECIFIED SORT ORDER SEQUENCE IS INVALID
The digits representing the sort order must be continuous and start with the digit 1.
None.
Specify a correct value and press Enter.
EQQA266E
YOU ARE NOT AUTHORIZED TO READ THE OI DATA BASE
You have attempted to read the operator instruction (OI) database, but you are not authorized to read it.
The system waits for you to respond.
If you require access to the OI database, contact your security administrator
EQQA267E
YOU ARE NOT AUTHORIZED TO UPDATE THE OI DATA BASE
You have attempted to update the operator instruction (OI) database, but you are not authorized to update it.
The system waits for you to respond.
If you require update authority to the OI database, contact your security administrator.
EQQA268E
CONDITION NUMBER VALUE MUST BE 1-999
See text.
None.
Specify a correct value and press Enter.
EQQA269E
CONDITION TYPE MUST BE RC OR ST
See text.
None.
Specify a correct value and press Enter.
EQQA271E
THERE IS AN INVALID CHARACTER IN JOBNAME
A job name can be made up of the following valid characters: A through Z, 0 through 9, and national characters (that is, #, $, and @). The first character must be alphabetic or national, the remaining characters can be alphabetic, numeric, and national characters.
None.
Correct the value and press Enter.
EQQA272E
THE FIRST CHARACTER IN GROUP ID MUST BE ALPHABETIC
See text.
None.
Specify a correct value and press Enter.
EQQA273E
THERE IS AN INVALID CHARACTER IN GROUP ID
A group ID can be made up of the following valid characters: A through Z, 0 through 9, and national characters (that is, #, $, and @).
None.
Specify a correct value and press Enter.
EQQA274E
THE FIRST CHARACTER IN JOBNAME MUST BE ALPHABETIC
See text.
None.
Specify a correct value and press Enter.
EQQA275E
THE WS RESOURCE AMOUNT MUST BE SPECIFIED
See text.
None.
Specify the workstation resource and press Enter.
EQQA276E
THE NUMBER OF PARALLEL SERVERS MUST BE SPECIFIED
See text.
None.
Specify the number of parallel servers and press Enter.
EQQA277E
THE FILTER NUMBER FNR IS NOT SUPPORTED
This message indicates a programming error.
The system waits for you to respond.
To collect appropriate documentation for problem determination, see the Diagnosis Guide and Reference manual, Chapter 3. Problem analysis procedures, section, "Information needed for all problems". If you cannot determine the cause of the error and the error persists, search the IBM Support database for a solution at Support.
Contact your system programmer.
EQQA278E
THE VERIFICATION NUMBER VNR IS NOT SUPPORTED
This message indicates a programming error.
The system waits for you to respond.
To collect appropriate documentation for problem determination, see the Diagnosis Guide and Reference manual, Chapter 3. Problem analysis procedures, section, "Information needed for all problems". If you cannot determine the cause of the error and the error persists, search the IBM Support database for a solution at Support.
Contact your system programmer.
EQQA279E
THE TABLE OF UPDATES CONTAINS DUPLICATE UPDATES
The table of pending updates cannot contain duplicate updates.
The system waits for you to respond.
Use the row command D to delete the duplicate updates or change the duplicates.
EQQA280E
THE TABLE CONTAINS DUPLICATE ROWS
The table cannot contain duplicate rows.
The system waits for you to respond.
Use the row command D to delete the duplicate row items or change the duplicates.
EQQA281E
NO MORE THAN 25 PENDING UPDATES CAN BE SPECIFIED IN THIS SESSION
It is not allowed to specify more than 25 pending updates in this session.
The system waits for you to respond.
Use the row command D to delete pending updates or cancel the latest pending updates.
EQQA282E
THE SPECIFIED BATCH JOB TYPE OPTION IS INVALID
A valid batch job type is T for trial run or U for updating run.
None.
Specify a correct value and press Enter.
EQQA283E
NO UPDATE AUTHORITY TO APPLICATION DESCRIPTION DATA BASE
You have attempted to update the application description database, but you are not authorized to update it.
The system waits for you to respond.
If you need to update the application description database, contact your security administrator
EQQA284E
YOU ARE NOT AUTHORIZED TO READ THE CALENDAR DATA BASE
You have attempted to read the calendar database, but you are not authorized to read it.
The system waits for you to respond.
If you need access to the calendar database, contact your security administrator
EQQA285E
YOU ARE NOT AUTHORIZED TO READ THE WS DESCRIPTION DATA BASE
You have attempted to read the workstation (WS) description database, but you are not authorized to read it.
The system waits for you to respond.
If you need to access the WS description database, contact your security administrator.
EQQA286E
THE DATA SPECIFIED IS TOO LONG
The data that you have specified for mass updating is longer than the maximum length allowed for the data item.
The system waits for you to respond.
Check the maximum data length allowed and enter the correct data.
EQQA287E
THE CONVERSION NUMBER CNR IS NOT SUPPORTED
This message indicates a programming error.
The system waits for you to respond.
To collect appropriate documentation for problem determination, see the Diagnosis Guide and Reference manual, Chapter 3. Problem analysis procedures, section, "Information needed for all problems". If you cannot determine the cause of the error and the error persists, search the IBM Support database for a solution at Support.
Contact your system programmer.
EQQA288E
THE RESCALE FACTOR IS NOT SPECIFIED
See text.
None.
Specify the rescale factor and press Enter.
EQQA289E
THE RESCALE FACTOR MUST BE A NUMBER 0 - 999
See text.
None.
Specify a correct value and press Enter.
EQQA290E
VALID DATA IS A NUMBER 1 - 99
See text.
None.
Specify a correct value and press Enter.
EQQA291E
VALID DATA IS A NUMBER 0 - 99
See text.
None.
Specify a correct value and press Enter.
EQQA292E
VALID DATA IS A NUMBER 100 - 999
See text.
None.
Specify a correct value and press Enter.
EQQA293E
VALID DATA IS A NUMBER 0 - 999
See text.
None.
Specify a correct value and press Enter.
EQQA294E
PERIOD/RULE NAME FILTER IS NOT RELEVANT FOR CURRENT DATA ITEM
See text.
None.
Remove the incorrect filter and press Enter.
EQQA295E
JOBNAME FILTER IS NOT RELEVANT FOR CURRENT DATA ITEM
See text.
None.
Remove the incorrect filter and press Enter.
EQQA296E
WS NAME FILTER IS NOT RELEVANT FOR CURRENT DATA ITEM
See text.
None.
Remove the incorrect filter and press Enter.
EQQA297E
NEITHER JOBNAME NOR WS NAME IS RELEVANT FOR CURRENT DATA ITEM
See text.
None.
Remove the incorrect filter and press Enter.
EQQA298E
FILTER CRITERIA ARE NOT RELEVANT FOR OWNER ID
See text.
None.
Remove the incorrect filter and press Enter.
EQQA299I
DATA SET NAME GIVEN; SPECIFIED APPLICATION ID(S) IGNORED
When the name of the data set is specified, it is not necessary to specify the application IDs.
None.
None.
EQQA300E
VALID DATA IS A NUMBER 1 - 255
See text.
None.
Specify a correct value and press Enter.
EQQA301E
THERE MUST BE AT LEAST ONE OPERATION IN AN APPLICATION
The application has no operations. You must specify at least one operation.
The system waits for you to respond.
Specify one or more operations for the application.
EQQA302E
PREDECESSOR OPERATION PO IS NOT FOUND FOR OPERATION OP
The predecessor operation (predecessor operation number PO) was not found for the operation (operation number OP). An internal predecessor operation must exist within the application.
The system waits for you to respond.
Enter an existing operation number.
EQQA303E
OPERATION OP IS NOT CONNECTED TO APPLICATION
The operation (operation number OP) has no predecessor or successor connections to the application.
The system waits for you to respond.
Enter or change an internal predecessor to establish a correct application link.
EQQA304E
OPERATION OP SPECIFIES WORK STATION OPWS, WHICH IS NOT FOUND
The operation (operation number OP) of this application specifies a workstation (workstation name OPWS), which was not found in the workstation description database.
The system waits for you to respond.
Enter an existing workstation name or use the Workstation Description dialog to define the workstation name.
EQQA305E
DEPENDENCIES INCLUDING OPERATION OP FORM A LOOP
A loop was detected in the operation (operation number OP) dependency network which must be corrected. For example, operation 10 has operation 5 as its predecessor, and operation 5 has operation 10 as its predecessor.
The system waits for you to respond.
Correct the found loop with these internal predecessors.
EQQA306E
VALID-FROM DATE LATER THAN VALID-TO DATE
When modifying an application, the valid-from date cannot be changed to a date later than the valid-to date.
None.
Correct the value and press Enter.
EQQA307E
OPERATION INPUT ARRIVAL TIME MUST BE SPECIFIED FOR A TIME JOB
If the time-dependent job option is specified as YES, an operation input arrival time must be specified.
None.
Set the operation input arrival time and press Enter.
EQQA308E
JOB SETUP OPERATION OP MUST HAVE A CPU SUCCESSOR
The job setup operation (operation number OP) must have a CPU successor operation.
The system waits for you to respond.
Enter the job setup operation number as a CPU predecessor number.
EQQA309E
PRINT OPERATION OP MUST HAVE A CPU PREDECESSOR
The print operation (operation number OP) must have a CPU predecessor operation.
The system waits for you to respond.
Enter a CPU operation number as the predecessor number.
EQQA310E
FIELD FORMAT SPECIFIED AS DBCS BUT INPUT NOT BRACKETED DBCS
See text.
None.
Specify a correct value and press Enter.
EQQA311E
DBCS PART OF BRACKETED FIELD IS BLANK
See text.
None.
Specify a correct value and press Enter.
EQQA312E
COND OP DOES NOT EXIST, ENTER WS NAME
While specifying an external conditional predecessor, you entered no workstation name and a number that does not correspond to any operation defined for the external application.
The system waits for you to respond.
Enter a valid workstation name to get a list of jobs available as conditional predecessors.
EQQA313E
COND OP DOES NOT EXIST IN THE AD APPLICATION
While specifying an external conditional predecessor, you entered a number that does not correspond to any operation defined for the external application.
The system waits for you to respond.
Enter a valid number. To get a list of jobs available as conditional predecessors, enter a valid workstation name and do not enter any data as operation number.
EQQA314E
THE OWNER ID IS NOT SPECIFIED
See text.
None.
Specify the owner ID and press Enter.
EQQA315E
FORMAT OF OWNER ID SPECIFIED AS DBCS BUT INPUT NOT BRACKETED
See text.
None.
Specify a correct value and press Enter.
EQQA316E
DBCS PART OF BRACKETED OWNER ID FIELD IS INVALID
See text.
None.
Specify a correct value and press Enter.
EQQA317E
DBCS FIELD CONTAINS UNPAIRED SHIFT-OUT / SHIFT-IN CHARACTER
The field indicated by the cursor contains one or more superfluous shift-out or shift-in characters.
The data is rejected.
Correct data and reenter.
EQQA318E
DBCS PART CONTAINS INVALID DBCS-CHARACTER
The field indicated by the cursor contains out-of-range DBCS characters. With the exception of DBCS blank, X'4040', each byte must be within the range X'41' - X'FE'.
The data is rejected.
Correct data and reenter.
EQQA319E
DBCS PART CONTAINS AN ODD NUMBER OF BYTES
The field indicated by the cursor is specified as a DBCS field, and requires two bytes per character.
The data is rejected.
Correct data and reenter.
EQQA321E
THE SPECIFIED DATA EXCEEDS THE ALLOWED LENGTH
See text.
None.
Specify a correct value and press Enter.
EQQA322E
CONDITION OPERATOR MUST BE CLOG.
See text.
None.
Specify CLOG and press Enter.
EQQA323E
CONDITION CHECK VALUE MUST BE CVAL.
See text.
None.
Specify CVAL and press Enter.
EQQA324E
CONDITION MUST HAVE AT LEAST ONE CONDITION DEPENDENCY.
The condition has no dependencies defined. You must specify at least one condition dependency.
The request is rejected.
Specify one or more condition dependencies.
EQQA325E
CONDITIONS CANNOT BE DEFINED ON A NOT CENTRALIZED OPERATION
The COND command is not supported on an end-to-end operation that is not centralized.
The COND command is not run. Remove the conditions and try the operation again.
Remove the conditions and rerun the operation again.
EQQA326E
YOU MUST DELETE ALL CONDITIONS BEFORE SETTING CENTRALIZED OPTION TO NO.
You are trying to set the centralized option to NO for an end-to-end operation that has conditions defined.
None
First remove the conditions defined on the end-to-end operation and then try again to set the centralized option to NO in the EQQAMJBP panel.
EQQA327E
VALUE2 FIELD MUST BE GREATER OF VALUE1 FIELD.
You entered an upper boundary greater than the lower one as range values.
The data is rejected.
Enter consistent boundaries for the RG operator.
EQQA329E
CONDITIONAL INTERNAL PREDECESSOR NOT FOUND.
The specified predecessor does not exist in the database.
The request is rejected.
Correct the input and reenter.
EQQA330E
CONDITION CHECK VALUE MUST BE 000-FFF (IF UXXX, SXXX) OR 0-9999.
See text.
None.
Specify a correct value and press Enter.
EQQA331E
CONDITION CHECK VALUE CANNOT BE UFFF, SFFF, OR 9999 IF CondOP=GT.
See text.
None.
Specify a correct value and press Enter.
EQQA332E
CONDITION CHECK VALUE CANNOT BE U000, S000, OR 0 IF CondOP=LT.
See text.
None.
Specify a correct value and press Enter.
EQQA333E
CONDITION CAN BE ADDED ONLY ON WAITING OR READY OPERATIONS
You requested to create a new condition for an operation that is not in ready or waiting status.
The request is rejected.
Check the operation status before repeating the request.
EQQA334E
CONDITIONAL PREDECESSOR CANNOT BE ADDED IF REMOVED FROM PLAN
You requested to create a condition dependency specifying a predecessor that was removed by daily planning.
The request is rejected.
Consider specifying a different conditional predecessor.
EQQA335E
CONDITION CHECK VALUE1 CANNOT BE UFFF, SFFF OR 9999 IF CONDOP=RG
You specified the maximum allowed value as first boundary of a range.
The request is rejected.
Enter a correct value, lower than the maximum allowed.
EQQA336E
THERE IS AN INCORRECT CHARACTER IN STEPNAME
STEPNAME can be made up of the following valid characters: A through Z, 0 through 9, and national characters (that is, #, $, and @). The first character must be alphabetic or national, the remaining characters can be alphabetic, numeric, and national characters.
None.
Specify a correct value and press Enter.
EQQA337E
THE FIRST CHARACTER IN STEPNAME MUST BE ALPHABETIC
See text.
None.
Specify a correct value and press Enter.
EQQA338E
THERE IS AN INCORRECT CHARACTER IN PROCSTEP
PROCSTEP can be made up of the following valid characters: A through Z, 0 through 9, and national characters (that is, #, $, and @). The first character must be alphabetic or national, the remaining characters can be alphabetic, numeric, and national characters.
See text.
None.
Specify a correct value and press Enter.
EQQA339E
THE FIRST CHARACTER IN PROCSTEP MUST BE ALPHABETIC
See text.
None.
Specify a correct value and press Enter.
EQQA340E
JOB STREAM WORKSTATION MUST BE SPECIFIED
See text.
None.
Specify a workstation and press Enter.
EQQA341E
JOB STREAM NAME MUST BE SPECIFIED
See text.
None.
Specify a job stream and press Enter.
EQQA342E
JOB NAME MUST BE SPECIFIED
See text.
None.
Specify a job name and press Enter.
EQQA343E
INVALID SELECTION FOR REMOTE ENGINE WORKSTATIONS
The selected information cannot be specified for remote engine workstations.
None
Specify valid information for remote engine workstations and try the operation again. See Managing the Workload for details.
EQQA344E
SELECTION IS ALLOWED ONLY FOR REMOTE ENGINE WORKSTATIONS
Remote job information is not available for non-remote engine workstations.
None
Remove all the remote job information and try the operation again. See the Managing the Workload for details.
EQQA345E
DATA SPECIFIED CONTAINS INVALID CHARACTERS
See text.
None.
Specify a correct value and press Enter.
EQQA346E
REMOTE JOB INFORMATION MUST BE SPECIFIED
Remote job information must be specified if the operation is defined to run on a remote engine workstation.
None
Specify the remote job information and try the operation again. See Managing the Workload for details.
EQQA347E
INCONSISTENT OPTION FOR AN OPERATION ON A REMOTE ENGINE WORKSTATION
The operation option specified is not supported on operations defined on remote engine workstations.
None
Specify a valid option and try the operation again. See Managing the Workload for details.
EQQA348E
COND CANNOT BE SPECIFIED ON AN OPERATION DEFINED ON A REMOTE ENGINE WORKSTATION
The COND command is not supported on an operation defined on a remote engine workstation.
The COND command is not run.
Remove the COND command and try the operation again. See Managing the Workload for details.
EQQA350E
THE RUN DAY SHIFT MUST BE A NUMBER FROM -999 TO -1 OR 1 TO 999.
See text.
None.
Specify a correct value and press Enter.
EQQA351E
RUN CYCLE SHIFT TYPE MUST BE INSERTED IF SHIFT IS SPECIFIED.
See text.
None.
Specify a correct value and press Enter.
EQQA352E
THE RUN CYCLE SHIFT TYPE IS INVALID, ENTER EITHER W OR F.
See text.
None.
Specify a correct value and press Enter.
EQQA400E
NO MATCHING JOB DESCRIPTION(S) FOUND
No job descriptions were found matching the generic or non-generic search criteria that you specified to generate a list of jobs.
The system waits for you to respond.
Try again, with different selection criteria.
EQQA401E
NO MATCHING JOB DESCRIPTION FOUND
The job that you selected from a list does not have a matching job description. The job may have been deleted or modified after the list of job entries was generated.
The request is rejected.
Return to the Job Selection Criteria panel and press Enter to generate a fresh list of jobs.
EQQA402I
NO RUNCYCLES FOUND FOR THIS JOB
You tried to display the run cycles for a job for which no run cycles have been specified.
The request is rejected.
None.
EQQA403I
THE JOB IS CREATED
The job has been created and saved as a job description.
None.
None.
EQQA404I
THE SELECTED JOB IS MODIFIED
The job has been modified and saved as a job description.
None.
None.
EQQA405E
THE WS SPECIFIED IS NOT A CPU WS OR A GENERAL WS WITH WTO SET
See text.
None.
Specify a valid workstation and press Enter.
EQQA406E
A JOB WITH THIS ID ALREADY EXISTS
You tried to create a job with an ID that already exists in the application description database.
The system waits for you to respond.
Enter a unique job ID. If you want to create a new version of an existing job, use the copy function.
EQQA407E
THE JOB IS BEING UPDATED BY ANOTHER USER
Another user is currently updating the job that you want to update.
The system waits for you to respond.
Try again later.
EQQA408E
THE JOBNAME HAS NOT BEEN SPECIFIED
See text.
None.
Specify a job name and press Enter.
EQQA409I
THE SELECTED JOB IS DELETED
The selected job has been deleted from the job description database.
None.
None.
EQQA410E
THE JOB DIALOG CANNOT BE USED WHEN DBCS IS DEFINED FOR APPLID
You have tried to enter the job description dialog but DBCS bracketed input has been defined for application IDs in your installation. The application ID of job descriptions must be the same as the job name. Job names cannot be entered in DBCS bracketed format.
The panel is redisplayed with this error message.
Use the Application Description dialog instead.
EQQA411E
WORK STATION MUST BE SPECIFIED
The workstation pointed to by the cursor must be entered.
None.
Specify a workstation name and press Enter.
EQQA412E
WORK STATION SPECIFIED IS NOT A VALID JCL PREPARATION WORK STATION
The workstation must be a workstation with the JCL preparation indicator set to Y.
None.
Specify a correct workstation and press Enter.
EQQA413E
WORK STATION SPECIFIED IS NOT A VALID MANUAL WORK STATION
The workstation must be a MANUAL workstation.
None.
Specify a correct workstation and press Enter.
EQQA414E
24.00 NOT ALLOWED AS A FROM-RUN TIME
See text.
None.
Specify a correct value and press Enter.
EQQA415E
NO PREDECESSORS FOUND THAT MATCH SELECTION CRITERIA
You tried to select predecessors for a job. No predecessors were found with the specified selection criteria.
The request is rejected.
Specify a different selection criteria and resubmit the request. See Managing the Workload for details.
EQQA416E
00.00 NOT ALLOWED AS A TO-RUN TIME
See text.
None.
Specify a correct value and press Enter.
EQQA418E
FROM-RUN TIME MUST BE SPECIFIED
Either a run time has been entered or run cycles are missing.
None.
Specify a from-run time.
EQQA419E
INTERNAL PREDECESSORS ARE NOT ALLOWED FOR JDS
If you are currently defining a job, the application ID must be completed for a predecessor.
None.
Complete the application ID and press Enter.
EQQA500E
GROUP DEFINITION CANNOT HAVE OPERATIONS
A group definition cannot contain operations.
The system waits for you to respond.
If operations are to be defined in this application, change the application type to A.
EQQA501W
GROUP DEFINITION APPLGRID COULD NOT BE FOUND IN AD FILE
The current application description (AD) references an application group definition that cannot be found in the AD database. Either you entered the wrong name, or the application group has not yet been created, or the application group has a pending status (not selectable for processing), or you are not authorized to reference it. If you want to, and if you are authorized, you can save the current application description while it references an application group that does not exist. Such an application description is not used to create occurrences in the long term plan (LTP).
The system waits for you to respond.
If you want the application description to be selected by LTP programs, enter the correct group definition ID, or create the referenced group definition with the application status field set to A.
EQQA502E
GROUP DEFINITION ID FIELD CAN BE FILLED IN ONLY WHEN NO RUN CYCLES
You cannot specify a group definition ID when run cycles already exist.
The system waits for you to respond.
Either erase the data in the group definition ID field or delete the run cycles for the application.
EQQA503E
GROUP DEFINITION CANNOT BELONG TO ANOTHER GROUP
You can specify a group definition ID only when the application type is A.
The system waits for you to respond.
Change the application type to A or erase the group definition ID field.
EQQA504E
APPLICATION TYPE MUST BE OCHCSTN, OCHCGRP OR BLANK
The selection criteria that you have specified contains an invalid application type. OCHCSTN and OCHCGRP are the national language characters for 'A' (applications) and 'G' (group definitions).
The system waits for you to respond.
Enter the correct characters for applications or group definitions, or blank to select both applications and group definitions.
EQQA505E
TYPE MUST BE OCHCSTN OR OCHCGRP
You have specified an invalid application type. OCHCSTN and OCHCGRP are the national language characters for 'A' (applications) and 'G' (group definitions).
The system waits for you to respond.
Enter one of the supported application types.
EQQA506I
RUN COMMAND NOT ALLOWED. APPLICATION IN A GROUP CONTAINS NO RUN CYCLE
An application that references a group definition for run cycle information does not itself contain run cycles.
The request is rejected.
None.
EQQA507I
OPER COMMAND NOT ALLOWED. A GROUP DEFINITION DOES NOT HAVE OPERATIONS
A group definition (application type=G) does not contain operations.
The request is rejected.
None.
EQQA508E
RUN CYCLES ARE NOT ALLOWED FOR A JOB DESCRIPTION IN A GROUP
A job description that references a group definition for run cycle information cannot itself contain run cycles.
The system waits for you to respond.
Either erase the data in the group definition ID field or delete the run cycles for this job description.
EQQA509I
NO RUN CYCLES FOR A JOB DESCRIPTION IN A GROUP
A job description that references a group definition for run cycle information cannot itself contain run cycles.
The request is rejected.
None.
EQQA510E
PRIORITY CANNOT BE SPECIFIED FOR A GROUP DEFINITION
You cannot specify priority for a group definition.
The system waits for you to respond.
Erase the data in the priority field.
EQQA511E
CALENDAR CANNOT BE SPECIFIED FOR AN APPLICATION IN A GROUP
A calendar ID cannot be specified for an application that references a group definition for run cycle information.
The system waits for you to respond.
Either erase the data in the calendar ID field or erase the data in the group definition ID field.
EQQA512E
GROUP DEFINITION CANNOT BELONG TO ANOTHER GROUP
Group definitions can be specified only when the application type is A (application) or blank (both application and group definition).
The system waits for you to respond.
Change the application type to A or blank, or erase the data in the group definition ID field.
EQQA513I
COMMAND NOT VALID FOR A GROUP DEFINITION
Calculate and print rundays, or Modify long term plan (LTP) can be requested only for applications.
The request is rejected.
None.
EQQA514W
GROUP DEFINITION HAS NO RUN CYCLES
The group definition contains no run cycle information. Applications that reference this group definition are automatically included in the long term plan.
The system waits for you to respond.
If you want to use this group definition to schedule applications, specify run cycle information.
EQQA515E
CALENDAR CANNOT BE SPECIFIED FOR A JOB IN A GROUP
A calendar ID cannot be specified for a job that references a group definition for run cycle information.
The system waits for you to respond.
Either erase the data in the calendar ID field or erase the data in the group definition ID field.
EQQA516E
NO RUN CYCLES FOR AN APPLICATION IN A GROUP
An application that references a group definition for run cycle information cannot itself contain run cycles.
The request is rejected.
Remove the run cycles from the application that belongs to a group.
EQQA517E
USER FIELD TABLE CONTAINS DUPLICATED RESOURCES
In the user field table, the same user field name was specified in more than one line.
None.
Correct the user field table and press Enter.
EQQA518E
THE NUMBER OF USER FIELDS EXCEEDS THE MAXIMUM LIMIT
Too many user fields were specified; the maximum allowed is 120.
The system waits for you to respond.
To correct the error, delete one or more user fields.
EQQA519E
THE NUMBER OF VARIABLE DURATIONS AND DEADLINES IS TOO LARGE.
Too many variable durations and deadlines were specified.
The system waits for you to respond.
To correct the error, delete one or more variable durations and deadlines.
EQQA520E
THE RULE ON WHICH THE RUN CYCLE IS BASED MUST BE DEFINED
A rule-based run cycle (type R or E) was inserted or replicated in the run cycle table, but no rule definition was specified.
The request is rejected.
Use the S row command to select the Rule Modification panel and define the rule.
EQQA521E
A VALID RULE NAME MUST BE SPECIFIED
You have not entered a valid rule name. A valid rule name hasa maximum of 8 characters, where the first character is alphabetical and the remaining characters are alphanumeric or national.
The request is rejected.
Specify a valid rule name.
EQQA522E
THE RULE NAME MUST BE UNIQUE WITHIN AN AD
You have specified a rule name that has already been defined for a rule-based run cycle for this application description.
The request is rejected.
Specify a unique rule name.
EQQA523E
THE RUN CYCLE TYPE HAS BEEN INCORRECTLY MODIFIED
You have modified the type from an offset-based run cycle to a rule-based run cycle, or vice versa. You can only change type within the run cycle subtype; that is, N and X for offset-based run cycles, or R and E for rule-based run cycles.
The request is rejected.
Specify one of the required types or create a new run cycle.
EQQA524E
CONDITION RULE SUBSET VALUE MUST BE FROM 1 UP TO ROW NUMBER
The specifies value cannot exceed the number of specified condition dependencies.
EQQA525E
CONDITION CHECK VALUE MUST BE SET
See text.
None.
Set the value and press Enter.
EQQA526E
CONDITION CHECK VALUE MUST BE COMPATIBLE
You specified a value not compatible with condition check type or operator.
The request is rejected.
If you specified abend codes as return code range, they must be both in the form Sxxx or Uxxx.
EQQA527E
CONDITION STATUS T OR F CANNOT BE CHANGED
The condition status does not allow the requested change.
The request is rejected.
Remove the changes in the condition status.
EQQA528E
CONDITION NUMBER CANNOT BE CHANGED
You cannot change the condition identifier.
The request is rejected.
Remove the change in the condition number and try the operation again.
EQQA530E
INVALID SELECTION WHEN FT WORKSTATION
This value is wrong for a fault-tolerant workstation. The fault-tolerant workstation requires a default value.
The request is rejected.
Enter one of the permitted values and try the operation again. See Managing the Workload for details.
EQQA531E
INCONSISTENT OPTION WHEN FT WORKSTATION
This option is wrong for a fault-tolerance workstation. The fault-tolerant workstation requires a default value.
Request is rejected.
Enter one of the permitted values and try the operation again. See Managing the Workload for details.
EQQA532E
FTW CANNOT HAVE A JOB SETUP AS IMMEDIATE PREDECESSOR
The fault-tolerant workstation does not accept a general workstation as a predecessor.
The request is rejected.
Enter the correct value.
EQQA533E
FTW CANNOT HAVE A PRINT OPERATION AS IMMEDIATELY SUCCESSOR
The fault-tolerance workstation does not accept a printer workstation as a predecessor.
Request is rejected.
Enter the correct value.
EQQA534E
JOB SETUP NOT AVAILABLE FOR NOT CENTRALIZED FTW OPERATIONS
- The operation must run on a CPU.
- The CPU must not be a fault-tolerant workstation or the operation must use centralized script support.
- The operation's jobname must be equal to the job setup name.
The request is rejected.
Enter the correct value.
EQQA535E
AUTOMATION INFO AVAILABLE FOR A NOT-AUTOMATION WORKSTATION
System automation information is available for a workstation that is not-Automation.
The request is rejected.
Specify a valid value. Ensure that the workstation has the Automation option set to Yes. If you changed the workstation from Automation to not-Automation, change it back or use a workstation that is Automation. If you no longer need the System Automation operation, you cannot change it to be a not-Automation one; you must delete it and create a new one. If you cannot delete the operation for any reason, you can leave a System Automation workstation and define a dummy System Automation command for it in the command text.
EQQA536E
AUTOMATION INFO NOT DEFINED FOR AN AUTOMATION WORKSTATION
System automation information was not defined, but at least the command text is required for an Automation workstation.
The request is rejected.
Specify the requested value.
EQQA537E
AUTOMATION INFO SELECTED FOR OP OP, WORKSTATION NOT FOR AUTOMATION
Automation information were specified for a not Automation workstation.
The request is rejected.
Enter a valid value. Automation information can be specified only for automation workstations.
EQQA538E
AUTOMATION INFO NOT AVAILABLE FOR OP OP, WORKSTATION IS FOR AUTOMATION
Automation information is not available for an Automation workstation.
The request is rejected.
Enter a valid value. Automation information (the command text, at least) must be provided for automation workstations.
EQQA539E
INCONSISTENT OPTION WHEN SA WORKSTATION
This option is wrong for a System Automation workstation. The System Automation workstation requires the default value.
The request is rejected.
Enter a valid option.
EQQA540E
INAPPROPRIATE SELECTION: SUBMIT=N WITH WORKSTATION=REMOTE.
For a job defined on a remote workstation (shadow job) you must set the automatic submission to Yes (Y), otherwise the cross dependencies feature does not work properly for that job.
Processing stops.
Change the automatic submission to Yes.
EQQA600E
THE FUNCTION REQUESTED IS UNKNOWN.
An incorrect request was received from the Dynamic Workload Console.
The request is rejected.
To collect appropriate documentation for problem determination, see the Diagnosis Guide and Reference manual, Chapter 3. Problem analysis procedures, section, "Information needed for all problems", sub-section, "Information to collect for JCL editing problems". If you cannot determine the cause of the error and the error persists, search the IBM Support database for a solution at Support.
EQQA601E
THE JOB LIBRARY DYNAMIC ALLOCATION FAILED.
The job library dynamic allocation failed.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA602E
THE OPEN OF THE JOB LIBRARY FAILED.
The program cannot open the job library.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA603E
THE RECORD LENGTH OF THE JOB LIBRARY IS INVALID.
The record length of the job library is incorrect.
The request is rejected.
Check that the job library data set was correctly created.
EQQA604E
THE FIND OF A JCL MEMBER IN THE JOB LIBRARY FAILED.
The program cannot find the JCL member in the job library.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA605E
THE READ OF A JCL MEMBER IN THE JOB LIBRARY FAILED.
The program cannot read the JCL member in the job library.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA606E
THE CLOSE OF THE JOB LIBRARY FAILED.
The program cannot close the JCL member in the job library.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA607E
THE JCL MEMBER SPECIFIED IS EMPTY.
The operation cannot be performed because JCL member specified is empty.
The request is rejected.
Correct the JCL member and retry the operation.
EQQA608E
THE JOB LIBRARY DYNAMIC DEALLOCATION FAILED.
The job library dynamic deallocation failed.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA609E
THE STORAGE NEEDED TO PROCESS THE REQUEST WAS NOT AVAILABLE.
The operation cannot be performed because of a memory problem
The request is rejected.
Check the memory allocation in the controller.