Creating ODBC or native connections
Create ODBC or native connections so that the Unica Campaign server can access the Unica Campaign database. Create ODBC or native connections on the computer where you installed the Unica Campaign server.
About this task
The computer on which the Unica Campaign server is installed must have an ODBC or native connection to the following databases:
- The database or schema that contains the Unica Campaign system tables
- The database or schema that contains the customer tables (sometimes called user tables).
Note: If you are configuring just one partition, name the data source UA_SYSTEM_TABLES. If you are
configuring more than one partition, do not name any of the data sources
UA_SYSTEM_TABLES. For more information, refer Configuring multiple partitions for Unica Campaign.
Use the following guidelines to create these ODBC or native connections:
- For databases on UNIX™/SUSE: Create native connections for DB2® and Oracle databases or ODBC connections for other databases, such as Teradata, Netezza®. The procedure for creating a native data source differs depending on the data source type and the version of UNIX™. See the data source and operating system documentation for specific ODBC driver installation and configuration instructions.
- For databases on Windows™: Create a new ODBC connection in the Control Panel Administrative Tools > Data Sources (ODBC) section.
- For DB2® databases on z/OS®: The database user account must have SYSADM privileges. The DBADM privilege is not sufficient because it does not provide access to all of the required system objects. Without SYSADM privileges, flowcharts might not run successfully.
- For MariaDB: Set the following parameters in MariaDB configuration (.cnf
or my.ini) file for Platform and Campaign.
- Lower_case_table_names: The value is 1, so that table names are considered as case insensitive.
- Set wait_timeout= <
Time in seconds that the server waits for a connection to become active before closing it. The session value is initialized when a thread starts up from either the global value, if the connection is non-interactive, or from the interactive_timeout value, if the connection is interactive.
>. For example: set this to 25,92,000 (seconds), in case the setup can be inactive for 30 days. - max_connections= <
The maximum number of simultaneous client connections
>. - innodb_strict_mode = 0
Note: Unica Campaign supports certain versions of DB2® on z/OS® for customer tables only, not system tables. For more information, see the Recommended Software Environments and Minimum System Requirements.
Be sure to record the ODBC name in the Unica Campaign installation worksheet.