Log Entry tab: Script Support Functions dialog box
You use the Log Entry tab to insert a log message into a Functional Test scripts and indicate whether it is a message, warning, or an error. During playback, HCL OneTest™ UI inserts this information into the log.
The Log Entry tab has the following controls:
- Message to write to the log
- Enter the text you want to include in the log.
- Result
- Select the type of message you want to add to the log. The result type
will be displayed in the log.
- Information
- Indicates that the text will be entered as a message.
- Warning
- Indicates that the text will be entered as a warning. The warning state is also reflected in the endScript message result type.
- Error
- Indicates that the text will be entered as an error. The error state is also reflected in the endScript message result type.
- Insert Code
- Inserts code into the script based on the option you selected in the Result section,
where
message
is the text you entered:logInfo("message") logWarning("message") logError("message")
To open: If recording, click the Insert Script Support Commands button on the Recording Monitor toolbar and click the Log Entry tab. If editing, click the Insert Recording into Active Functional Test scripts button on the HCL OneTest™ UI toolbar, click the Insert Script Support Commands button on the Recording Monitor toolbar, and click the Log Entry tab.