Logging categories
The logging categories provide a variety of debugging information.
They are used to determine which severity levels and components to debug.
LogX=n
Provide the specific category, such as Trace, Debug, Info, Warning or Fatal, for X and 0 to turn that logging category off, or 1 (to turn that category on) for n.
Example: LogTrace=1
Logging Category | Value | Description |
---|---|---|
LogTrace | 0 | Disabled |
1 | Enables the logging of sequence of events Example Results: Before Resource Pending <map> After Resource Pending <map> |
|
LogDebug | 0 | Disabled |
1 | Enables the logging of information to diagnose adapter connection
behavior Example Results: New audit file name <name> Adapter wildcard.<wildcard> |
|
LogInfo | 0 | Disabled |
1 | Enables the logging of general information about the state
of adapter connections Example Results: :Map started InitPendingHigh reached |
|
LogWarning | 0 | Disabled |
1 | Enables the logging of issues that are not severe, but might
be important to know Example Results: Resource Manager table too small - using default Map warning <map> |
|
LogError | 0 | Disabled |
1 | Enables the logging of critical adapter connection errors Example Results: Map failure <map> Socket failure <socket_type> |
|
LogFatal | 0 | Disabled |