SMX_NUMPIPES configuration parameter
The SMX_NUMPIPES configuration parameter sets the number of pipes for server multiplexer group (SMX) connections.
- onconfig.std value
- SMX_NUMPIPES 1
- values
- 1 - 32767 = The number of network pipes for SMX connections.
- takes effect
- After you edit your onconfig file and restart the database server.
Usage
High-availability clusters and parallel sharded queries use SMX connections. If the lag time between servers is too long, increase the number of SMX pipes.
Note:
From 14.10xC6 onwards, Enterprise Replication uses SMX connection for communicating with peer servers.