Restoring canister safety limits
About this task
If the Canister Safety Limits event is not visible in the Events tab of the Events Manager, complete the following steps to restore it.
Here is the default definition that must be applied through Advanced Mode:
// Canister Safety Limits [BB]
function PALI$E_SAFETY_LIMITS()
{
//Default: 2048 Hits
if ($S.NumberOfHits > 2048)
TLCloseSession.CloseForSafetyHits();
//Default: 5242880 Bytes (5MB)
if (($S.TotalREQBytes + $S.TotalRSPBytes) > 5242880)
TLCloseSession.CloseForSafetySize();
//Default: 3600 Seconds (1 hour)
if ($S.TotalTime> 3600)
TLCloseSession.CloseForSafetyTime();
}
Procedure
- From the drop-down at the top of the Events tab, select
All Events
. - Select the Show Inactive check box to show events that may be inactive.
- Enter the value
Canister Safety
in event filter in the left bar of the Events tab. - If
Canister Safety Limits [BB]
is visible:- Right-click the event.
- Select Make Active if it is listed.
- If Make Inactive is in the context menu, the event is present and active. It was simply hidden from view by display settings. You may skip the rest of these steps.
- If
Canister Safety Limits [BB]
is not visible in the filtered list:- Contact your Discover administrator or other members of the Discover team to see if the event was not renamed.
- You can mouse over event names to reveal their tooltips.
In the tooltip for this event, the internal contains
E_SAFETY_LIMITS
.
- If you determined that the event was deleted, complete
the following steps, which enable you to re-create the event through
Advanced Mode in the Event Manager using the JavaScript™ definition above.