Configuring HBR Settings for Individual Canisters
In the following settings, X
indicates the index number for the canister. See
Per Processing Server.
- Setting
- Description
CanisterNameX
- Name or IP address of the target canister.
CanisterPipeIDX
- ID of the associated
HBR_PipelineX.cfg
so that HBR knows the child pipeline associated with the canister. CanisterAppNameX
- AppName value from the
HBR_PipelineX.cfg
file, so that HBR knows the Governor Status entry from the GovernorStatusEx command. CanisterSSPortX
- The search server port number for the target canister. The default
value is
19000
. CanisterPerSecMaxX
- Maximum hits/sec for the target canister, which overrides the default global setting and enables the deployment of canisters with different capacities. The default value is the global default value.
CanisterSSLogX
- Whether HBR requests should be logged to the Search Server log.
The default value is
False
.
Canister Down Times
HBR needs to be apprised of scheduled canister down times. For each canister, you can specify the daily or weekly times when HBR should wind down usage before stopping the flow of hits to the canister, so that maintenance tasks can be performed on it.
The following configurations describe multiple scheduled
downtimes for the same canister. Individual downtimes begin with the
same identifier (CanisterOffline=1
) and may be appended
with a unique extension (a
, b
) to
specify multiple downtimes.
Example configurations:
CanisterOffline1=Daily at 2300 for 10 minutes winddown 20 minutes
- Every day at 10:40 PM, stop the flow of new hits to this canister. At 11:00 PM, stop the canister for 10 minutes.
CanisterOffline1a=Tuesday at 0200 for 10 minutes winddown 20 minutes
- Every Tuesday at 1:40 AM, stop the flow of new hits to this canister. At 2:00 AM, stop the canister for 10 minutes.
CanisterOffline1b=Friday at 0500 for 10 minutes winddown 20 minutes
- Every Friday at 4:40 AM, stop the flow of new hits to this canister. At 5:00 AM, stop the canister for 10 minutes.
Disabling HBR-Canister Connections