Workload Automation Programming Language has been unable to read a file, possibly due to the DD name not
being allocated, or the input file never having been written to, or
the record format not being appropriate to read with EXECIO.
Additional
info may contain the following:
-NODD
The DD statement is not allocated.
-NOMEM
The member is not found within the DD statement.
-ALLOC <rc>
Allocation of the EQQTEMP file failed with RC=<rc>.
Workload Automation Programming Language terminates. Determine the problem with the file, correct it,
and rerun.
EQQI103W
Output file <DD name> not allocated - skipping
Workload Automation Programming Language has encountered an optional output file that has not been allocated. No output is written to this file, Workload Automation Programming Language continues. If the file should have been present, correct, and
rerun.
EQQI105W
Truncation occurred for file <DD name>
A file has been written to with at least one record
that is longer than the record length. The file is written with any oversize records are
truncated at the record length. Correct the record length and rerun.
EQQI106E
Failed writing to <DD name> RC=<RC> (records=<count>)
An attempt has been made to write to an output file
that has failed for reasons other than truncation. Possibly space
or authority. The return code is from the REXX EXECIO service.The file is not written successfully, it may contain
partial data.Determine the cause of the failure from return codes,
additional messages and other additional information, such as file
attributes. Correct and rerun.
EQQI108E
<number> <type> versions already exist for <object>
An attempt has been made to create a new version
of an object that is limited to the number of versions that can exist
at once.
Controlled types are:
Application
Limited to 4 versions per status.
No update takes place. Delete unwanted old versions before attempting a
rerun.
EQQI109E
Item already exists so cannot be added
A Batch Loader request using OPTIONS DBMODE(ADD) for an object that is already in the database has been
attempted. The object is not added to the database. Delete the object from the database or change the DBMODE to REPLACE and rerun.
EQQI110E
No key information specified
A Batch Loader request has been specified that does
not include any key fields to identify the object to update. The database is not updated. Amend the Batch Loader statements to include key
fields or use a USELIST and rerun.
EQQI111E
<list-name> contains records for <type1> instead of
<type2>
A request to use the results of a saved list has been
coded, but the list contains objects of a different type to the use
that is being applied to. No update takes place. Correct the control statements to use an appropriate
list and rerun.
EQQI113A
Options <keyword> may not have full effect for this stream
The keyword is one that affects the way control statements
are parsed. Workload Automation Programming Language will pre-parse an entire input stream of control statements to identify
valid statements, consolidate continuation and remove comments before
executing any of the statements. This means any subsequent statements
in the same stream might not benefit from the changes made by this OPTIONS statement and parsing errors, such as
unknown commands or keywords, may be reported.The new parsing behavior takes effect from the next
input stream.Verify whether this is acceptable, and possibly move
the OPTIONS statement to an earlier input stream.
Note: This warning
is only issued for the input streams for standard input (SYSIN) and
the REXX stack.
EQQI114E
<segment> not found to delete
An attempt has been made to remove a non-existent
segment from an existing object using the ACTION(DELETE) keyword in Batch Loader. The object is not updated. Correct the Batch Loader statements and rerun.
EQQI117W
<action> for <type> <key information> ended with
warnings
A Batch Loader request has completed but has produced
additional warning messages. This message clarifies the action being
attempted and identifies the object that has been used.
The action
can be INSERT, REPLACE, or SUBMIT.
. Batch Loader process completes with warnings. Review the warning messages, if necessary correct
and rerun.
EQQI118E
<action> for <type> <key information> failed
A Batch Loader request has failed to complete. This
message clarifies the action being attempted and identifies the object
that has been used.
The action can be INSERT, REPLACE, or SUBMIT.
Batch Loader process failed. Review the warning messages, correct and rerun.
EQQI120W
EXECUTE not performed
Statements to update the Current Plan have been processed
but not EXECUTE or RESET request has been performed. No updates are made to the Current Plan. Add an EXECUTE or RESET command to the control statements or use OPTIONS EXECUTE(AUTO).
EQQI121E
<count> matches found for LISTSTAT
More than one record was identified as matching the
arguments to the LISTSTAT request. Only one
record must be identified for LISTSTAT to
work.LISTSTAT fails. None.
EQQI124W
OUTPUT statement not found for parent of <segment> - ignoring
DATA(=)/LOADER(=)
An OUTPUT statement has been
coded with a DATA or LOADER keyword using = as the value. This
means that the destination for the parent segment should be used,
but when this message appears it means that an OUTPUT statement for a parent segment has not been coded. This message will be issued and the output stream
for the keyword will be ignored. Replace the = with a real
destination or code an OUTPUT statement for
the parent before this OUTPUT statement.
EQQI125E
COPY cannot replace existing records <key-information>
An attempt has been made to copy an object over the
top of an existing object using DBMODE(COPY). No update takes place. Either delete the existing object or alter the NEW
field specifications to create an object that does not already exist.
EQQI126E
Bad predecessor <pred> for <succ>
When both workstation and operation number are not
specified together for a dependency, Workload Automation Programming Language must look up the values using the information provided. This message
means not enough information was specified to uniquely identify a
predecessor. Either the input had more than one possible match, or
no match.No update takes place.Either provide both workstation and operation number,
or refine the statements to ensure a unique operation is identified.
EQQI127E
Cannot find a matching operation in the Current Plan
A command has been issued that needs to update an
operation in the current plan, but the information provided does not
match any operation in the plan. The command terminates without performing any update. Check the Current Plan to see if the operation you
wish to update is that, and if so correct the command to provide the
necessary information to locate the required operation.
EQQI128E
Unable to find unique Application <adid> valid on <date>
An attempt has been made to INSERT an occurrence into the Current Plan using an alias. The ADID
specified does not have a Valid Active version for the date it is
due to run on. An occurrence is not submitted. Correct and rerun.
EQQI129E
Unable to retrieve <type> <key information> from database
An attempt to SELECT a record
from the database has failed. The record is not retrieved. Additional messages may indicate why the failure
occurred. It may be that the object does not exist in the database.
If the SELECT was generated as a result of
a LIST statement it is possible that the object
was deleted by another user between the LIST and SELECT.
EQQI0131F
Unexpected data format for <segment> <field>
Workload Automation Programming Language has encountered a field when reading a record that does not match
the expected format as defined in the Workload Automation Programming Language data mapping. Subsequent EQQI0132A messages will be issued with
diagnostic information. A mini dump of the segment will be displayed.
The command fails and Workload Automation Programming Language stops processing further commands. Check that you are instructing Workload Automation Programming Language to run for the correct version of Workload Automation Programming Language and you have the correct OPTIONS SPE settings
for that subsystem.
EQQI134E
User field "<name>" not defined for this job
A VARSET USRF command has
been issued with MISSING(ERROR) and the named
user field was not defiled to the operation. The command fails. Correct the user field name or define the user field
to the operation.
EQQI135F
User field "<name>" not defined for this job
A VARSET USRF command has
been issued with MISSING(FAIL) and the named
user field was not defiled to the operation. The command fails and Workload Automation Programming Language stops processing further commands. Correct the user field name or define the user field
to the operation.
EQQI136F
File <ddname> not allocated
A command has been issued referring to a dd name
that does not exist in the step. The command fails and Workload Automation Programming Language stops processing further command. Correct the DD name in the command or add the DD
statement to the step.
EQQI137F
File <ddname> not available for input processing
A command has been issued referring to a dd name
that is not considered to be an input file, for example, a SYSOUT
file. The command fails and Workload Automation Programming Language stops processing further command. Correct the DD name in the command or correct the
DD statement in the JCL.
EQQI139F
All data sets in <ddname> must be cataloged for search
An INCLUDE command has been
issued referring to a member within a dd name that contains one or
more partitioned data sets that are not catalogued. To perform a concatenation
search Workload Automation Programming Language requires all of the data sets to be catalogued. The command fails and Workload Automation Programming Language stops processing further command. Either ensure all of the data sets are catalogued,
or allocate the specific member explicitly in the JCL and INCLUDE from that explicit DD statement without specifying
a member name.
EQQI140F
Member <name> not found in <ddname>
An INCLUDE command has been
issued referring to a member in a dd name that does not contain any
datasets in which the named member exists. The command fails and Workload Automation Programming Language stops processing further command. Correct the DD name in the INCLUDE statements or correct the DD statement in the step to include
a library containing the specified member.
EQQI141F
Unable to allocate <dataset> to <ddname>
A command the requires a dynamic allocation to the Workload Automation Programming Language temporary file has been issued. This is done whenever a member is
needed from a library that is specified in the JCL without the member
explicitly specified. The command fails and Workload Automation Programming Language stops processing further command. Identify the reason for failure and rerun. The most
likely cause is contention, but if you have also made a lot of dynamic
allocations in the step then DYNAMNBR may need specifying in the JCL.
EQQI143E
Cannot rename an item that does not exist
Batch loader has been specified with DBMODE
UPDATE or COPY that specifies
new key names using NEW_ fields, but the original
key refers to an object that does not exist. The command will fail. Correct the batch loader key fields.
EQQI144W
<UPDATE|COPY> will overwrite existing record <key information>
Batch loader has been specified with DBMODE
UPDATE or COPY that specifies
new key names using NEW_ fields. The new key
points to an existing record but OPTIONS OVERWRITE(Y) has been specified. The existing option will be overwritten. None.
EQQI145E
No user fields match <mask>
An INCLUDE statement has
been specified that has a mask which does not match any user fields
attached to the job. The command will fail. Correct the mask, or user fields against the operation.
EQQI146E
Table <name> could not be updated
A VARSAVE or SETVAR
SAVE command was issued, but Workload Automation Programming Language was unable to update the table. The command will fail, no updates were performed
to the named table. Determine the reason for failure. Most likely causes
are contention, trying to update a table that doesn't exist, or insufficient
access rights.
EQQI148F
Updates to the current plan have failed
A DELETE, INSERT or MODIFY command for a resource
beginning with CP has failed and OPTIONS CPFAIL(ABORT) is in effect. This is to protect against an incomplete
sequence of update actions being committed to the current plan. Return code 12 will be issued and processing will
stop unless OPTIONS HIGHRC has been amended. Determine the reason for failure and correct. If
you wish to allow processing to continue in such circumstances set OPTIONS CPFAIL(ERROR).
EQQI150W
No matching run cycles found within <application>
A PRSTART batch loader statement
has been executed that includes setting dates from an Application,
or a GETDATES command extracting dates from
an application has been run. There were not run cycles within the
application that matched either the Input Arrival or validity criteria.Workload Automation Programming Language will issue RC=4 and continue. None.
EQQI152E
An internal command failed – see previous messages
A command has been executed that internally calls
other Workload Automation Programming Language commands and one of these internal commands has failed. The reason for the failure will be listed in the
message group for the internal command, earlier in the Workload Automation Programming Language log. Respond to the earlier error messages.
EQQI155W
Application validity <date-range> is outside range <date-range>
A PRSTART batch loader statement
has been executed that includes setting dates from an Application,
or a GETDATES command extracting dates from
an application has been run. The named application is not in effect
within the range specified by the FROMDATE and TODATE keywords.Workload Automation Programming Language will issue RC=4 and continue. Determine if this is the correct behaviour. If not
alter the FROMDATE/TODATE range or correct the application and rerun.
EQQI160W
No entries found matching criteria
A command has been issued to find elements in the
database or plans, but nothing was found.Workload Automation Programming Language will issue RC=4 and continue. Review the output and correct if necessary.
EQQI164E
<adid> <opno> has no successors for CONNECT(SUCC)
The QUEUE command has been
issued with the CONNECT(SUCC) keyword specified.Workload Automation Programming Language will issue RC=8 and continue. Review the output and correct if necessary.
EQQI170E
Unable to activate console <console-name>
A CONSOLE command was unable
to activate an extended console. Workload Automation Programming Language will issue RC=8 and continue. Review associated messages and correct.
EQQI171E
External command returned negative RC (1)
A CALL command has executed
an external REXX routine that has resulted in a negative return code.
This is often caused by the REXX routine not being found in the execution
path.Workload Automation Programming Language will issue RC=8 and continue. Review the execution path to ensure the REXX routine
is accessible.
EQQI172W
Workstation <wsname> not suitable for <command>
A current plan operations command has been issued
to an operation for which it is not suitable. This may be because
the command has been issued to all operations in an occurrence, with
the intention of only applying the command to the operations that
are permitted. Workload Automation Programming Language will issue RC=4 and continue. Review the output and correct if necessary.
EQQI173E
Cannot lock <record-type> <key> for <update-mode>
A batch loader command has been issued for an object
that cannot be locked exclusively, after retrying in accordance with
the OPTIONS CONTENTION setting.Workload Automation Programming Language will issue RC=8 and continue. Identify and resolve the cause of contentions before
rerunning.
EQQI174W
An internal command issued warnings - see previous messages
A command has been executed that called other commands
internally that issued Warning messages effecting the success of the
command.Workload Automation Programming Language will issue RC=4 and continue. Review the messages from the preceding block of
messages.
EQQI175W
Missing interval for <wsname> - Cannot reset
A WSALTER command has been
executed that requested a reset of either parallel servers or resource
quantities, but the FROM and TO keywords do not point to an existing
interval.Workload Automation Programming Language will issue RC=4 and continue. An interval can only be reset if it already exists.
Either correct the FROM and TO to point to the existing interval covering
the time period you want to reset to planned values, or provide explicit
values for PSCAP, R1CAP and R2CAP for the time period concerned.
EQQI176E
Cannot find inserted job to edit JCL
An ADDJOB or JBSTART command has run with the JCL keyword, but the update process
is unable to locate the newly inserted job.Workload Automation Programming Language will issue RC=8 and continue.Investigate why the inserted job cannot be located
and rerun.
EQQI180W
Completed successor AD=<applicationID> IA=<YYMMDDHHMM>
OP=<nnn>
An ADDJOB or JBSTART command has run that has identified a defined successor that
is already in a complete state. An external predecessor cannot be
added to a completed operation. Keyword COMPSUCC(WARNING) has been specified.Workload Automation Programming Language will not apply the dependency, issue RC=4, and continue.Review the details to determine if further actions
are required.
EQQI181E
Completed successor AD=<applicationID> IA=<YYMMDDHHMM>
OP=<nnn>
An ADDJOB or JBSTART command has run that has identified a defined successor that
is already in a complete state. An external predecessor cannot be
added to a completed operation. Keyword COMPSUCC(ERROR) has been specified.Workload Automation Programming Language will not apply the dependency, issue RC=8, and continue.Review the details to determine if further actions
are required.
EQQI195W
File <ddname> not open
A CLOSE command has been
issued for a file that was not open.Workload Automation Programming Language will issue RC=4 and continue. Review the message to determine whether the file
name needs to be corrected or the CLOSE command
removed.
EQQI197W
End of file reached for <ddname> at <number> records
A READ command has been executed
that specified a number of records to read, but the file did not have
that many records within it.Workload Automation Programming Language will issue RC=4 and continue. Investigate the reason for the discrepancy and correct.
EQQI198E
Input file <ddname> not allocated for input
A command has been executed that requires an input
file, but the named DD is either not allocated, or does not refer
to an input file.Workload Automation Programming Language will issue RC=8 and continue. Correct the file allocations and rerun.
EQQI199E
Failed reading from file <ddname> RC=<return-code>
A command has been executed that reads a file, but
has failed.Workload Automation Programming Language will issue RC=8 and continue. Consult REXX documentation for the EXECIO command
for an explanation of the return code.
Have feedback?
Google Analytics is used to store comments and ratings. To provide a comment or rating for a topic, click Accept All Cookies or Allow All in Cookie Preferences in the footer of this page.