WSN - Workstation resource report record in DP
Name : DCLWSN Function: Describes layout of parallel servers, R1 and R2 indicating the planned workstation load measured in parallel servers, R1 and R2 units. There is one record for each workstation and 'day' in the plan. A 'day' starts|ends on the time given in planhour. For each 15 minutes the amount is recorded of R1/R2 resources needed (according to the operation descriptions) multiplied by 15 planned server minutes for all operations with start-end interval covering the interval (if 1/3 of the interval covered - 1/3*amount). An example: An operation planned between 14.30 and 14.48 using 1 server, 50 R1, and 2 R2 will record 15 server minutes, 15*50 R1 units and 15*2 R2 units in the 14.30-14.45 slot and will record 3 server minutes, 3*50 R1 units and 3*2 R2 units in the 14.45-15.00 slot. The records have the standard recsize and keysize of DPIN records.
Offsets
Dec
Hex
Type
Len
Name (Dim)
Description
0
(0)
STRUCTURE
273
WSNAREA
PARALLEL SERV|R1|R2 REC
0
(0)
CHARACTER
74
WSNKEY
KEY
0
(0)
SIGNED
2
WSNTYPE
ALWAYS TYPE 3
2
(2)
CHARACTER
8
WSNROUT
REPORT ROUTING
10
(A)
CHARACTER
4
WSNWSID
WORKSTATION ID
14
(E)
SIGNED
2
WSNSTYPE
SUBTYPE SERVER MINUTES= 3 R1 = 4 R2
= 5
16
(10)
CHARACTER
6
WSNDATE
REPORT 'DAY' (YYMMDD)
22
(16)
CHARACTER
2
WSNSTRNG
R1|R2 STRING IN REPORTS BLANK FOR
PARALLEL SERV
24
(18)
CHARACTER
1
WSNRPLN
RESOURCE PLANNING Y|N
25
(19)
CHARACTER
34
*
ADJUST TO KEYLENGTH
59
(3B)
CHARACTER
15
*
TO ADD UP TO 74 BYTES
74
(4A)
CHARACTER
199
WSNDATA
DATA PART OF WSN RECORD
74
(4A)
SIGNED
2
WSNFACT
FACTOR TO MULTIPLY AMOUNT
76
(4C)
UNSIGNED
1
WSNAMT (96)
OF RESOURCES
172
(AC)
UNSIGNED
1
WSNLIM (96)
LIMIT OF RESOURCES
268
(10C)
CHARACTER
5
*
TO ADD UP TO STD RECSIZE