EQQA610E - EQQA717W
EQQA610E
AN ERROR OCCURRED WHILE TRANSFERRING DATA WITH CROSS MEMORY.
An error occurred while transferring data with cross memory.
The system rejects the action.
Search the IBM Software database for a solution at Support.
EQQA611E
THE STOW OF A JCL MEMBER IN A JOB LIBRARY FAILED.
The STOW of a JCL member in a job library failed.
The system rejects the action.
Search the IBM Software database for a solution at Support.
EQQA612E
THE WRITE OF A JCL MEMBER IN A JOB LIBRARY FAILED.
The WRITE of a JCL member in a job library failed.
The system rejects the action.
Search the IBM Software database for a solution at Support.
EQQA613E
THE REQUEST FAILED BECAUSE THE JCL PROVIDED IS EMPTY.
The request failed because the JCL provided is empty.
None.
Ensure that the JCL has content.
EQQA614E
THE REQUEST FAILED BECAUSE THE JCL HAS INVALID RECORD LENGTH.
The request failed because the JCL has invalid record length.
None.
Search the IBM Software database for a solution at Support.
EQQA615E
THE INSERT OF A JCL FAILED BECAUSE THE MEMBER ALREADY EXISTS.
The INSERT of a JCL failed because the member already exists.
None.
You cannot have more than one JCL with the same name.
EQQA616E
THE DELETE OF A JCL FAILED BECAUSE THE MEMBER WAS NOT FOUND.
The DELETE of a JCL failed because the member was not found.
None.
Verify the name of the JCL that you want to delete and enter the name of an existing JCL.
EQQA617E
THE JFCB MACRO FAILED TO RETRIEVE THE JOBLIB DATASET LIST.
The JFCB macro failed to retrieve the JOBLIB dataset list.
None.
Search the IBM Software database for a solution at Support.
EQQA618E
THE DESERV MACRO FAILED TO RETRIEVE THE JOBLIB MEMBER LIST.
The DESERV macro failed to retrieve the JOBLIB member list.
None.
Search the IBM Software database for a solution at Support.
EQQA619E
THE LIST FILTER PROVIDED IS NOT VALID.
The list filter provided is not valid.
The request is rejected.
Enter a valid filter.
EQQA620E
AN UNKNOWN ERROR OCCURRED WHILE EXECUTING AN HTTP REQUEST.
An unknown error occurred while executing an HTTP request.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA621E
AN HTTP SELECT REQUEST WAS RECEIVED WITH NO INPUT DATA.
An HTTP SELECT request was received with no input data.
The request is rejected.
Search the IBM Software database for a solution at Support.
EQQA622E
THE RETRIEVE OF THE HTTP SELECT INPUT SEGMENT FAILED.
The retrieve of the HTTP SELECT input segment failed. A possible cause for this failure is that the input segment version is old.
The request is rejected.
Check that the z/OS connector is at the proper
level. If you recently upgraded z/OS connector, run Settings->Manage
Engines->Test Connection
in the Dynamic Workload console, to refresh its cached settings,
and retry your request.
If this is not the problem, search the IBM Software database for a solution at Support.
EQQA623E
THE HTTP SELECT REQUEST DESTINATION HAS AN INVALID METHOD.
The HTTP SELECT request destination has an invalid method.
The request is rejected.
Specify a valid workstation (either HTTP or HTTPS).
EQQA624E
THE HTTP SELECT REQUEST DESTINATION WAS NOT FOUND.
The HTTP SELECT request destination was not found.
The request is rejected.
Specify an existing destination.
EQQA625E
THE HTTP SELECT REQUEST HAS AN INVALID HTTP DESTINATION TYPE.
The HTTP SELECT request has an invalid HTTP destination type.
The request is rejected.
Specify a destination with a valid HTTP destination type (either broker or agent).
EQQA626E
THE ATTACH OF THE C PROCESS FAILED.
The ATTACH of the C process failed.
The system rejects the action.
Search the IBM Software database for a solution at Support.
EQQA627E
THE REQUEST TO THE DYNAMIC DOMAIN MANAGER FAILED WITH REASON CODE XSSRC.
The request to the Dynamic Domain Manager failed with reason code XSSRC. See Reason codes for a description of the reason code.
The request is rejected.
Correct the error and retry the operation.
EQQA628E
THE HTTP REQUEST FAILED WITH REASON CODE XSSRC.
The HTTP request failed with reason code XSSRC. See Reason codes for a description of the reason code.
The request is rejected.
Correct the error and retry the operation.
EQQA629E
THE C PROCESS FAILED WITH REASON CODE XSSRC.
The C process failed with reason code XSSRC. See Reason codes for a description of the reason code.
The action is rejected.
Correct the error and retry the operation.
EQQA630E
AN ERROR OCCURRED WHILE TRANSFERRING DATA WITH CROSS MEMORY.
An error occurred while transferring data with cross memory.
The system rejects the action.
Search the IBM Support database for a solution at Support.
EQQA631E
THE STORAGE NEEDED TO PROCESS THE REQUEST WAS NOT AVAILABLE.
The storage needed to process the request was not available.
The action is rejected.
Search the IBM Support database for a solution at Support.
EQQA632E
THE TEMPLATE YOU HAVE ENTERED IS NOT CORRECT.
The template you have entered is not correct.
The request is rejected.
Specify a valid template.
EQQA634E
THE FUNCTION REQUESTED IS UNKNOWN.
The function requested is unknown.
The request is rejected.
Search the IBM Support database for a solution at Support.
EQQA635E
AN UNKNOWN ERROR OCCURRED WHILE EXECUTING A DEST REQUEST.
An unknown error occurred while executing a DEST request.
The system rejects the request.
Search the IBM Support database for a solution at Support.
EQQA636E
THE NAME OF THE MEMBER CONTAINS AN INVALID CHARACTER.
The name of the member contains an invalid character.
The system rejects the request.
Specify an existing member name.
EQQA637E
THE NAME OF THE DATA SET IS INVALID.
The name of the data set is invalid.
The system rejects the request.
Specify an existing data set name.
EQQA638E
THE DELETE POOL HTTP REQUEST FAILED WITH REASON CODE XSSRC.
The delete pool HTTP request failed with reason code XSSRC. See Reason codes for a description of the reason code.
The request is rejected.
Correct the error and retry the operation.
EQQA639E
THE DELETE POOL HTTP REQUEST FAILED WITH REASON CODE &XSSRC
The HTTP request has failed. See Reason codes for a description of the reason code.
The request is rejected.
Correct the error and retry the operation.
EQQA640E
THE REQUEST CANNOT BE EXECUTED ON A BROKER DYNAMIC WORKSTATION.
- Pool
- Dynamic pool
- HCL Workload Automation for Z agent
The request is rejected.
Specify one of the workstation types where you can perform the operation. See Managing the Workload or the Dynamic Workload Console User's Guide for details.
EQQA641E
THE POOL CREATION FAILED. THE NAME CONTAINS UNSUPPORTED SPECIAL CHARACTERS.
The pool creation failed. The name contains unsupported special characters.
The request is rejected.
Correct the error and retry the operation.
EQQA642E
THE HTTP REQUEST FAILED. THE SPECIFIED WORKSTATION WAS NOT FOUND.
The HTTP request failed. The specified workstation was not found.
The request is rejected.
Correct the error and retry the operation.
EQQA643E
THE HTTP REQUEST CANNOT BE EXECUTED. THE JOB WAS NOT FOUND.
The HTTP request cannot be executed. The job was not found.
The request is rejected.
Correct the error and retry the operation.
EQQA644E
THE JOB CANNOT BE RESTARTED BECAUSE OF A DEPENDENCY WITH ANOTHER JOB.
The job cannot be rerun, restarted, or refreshed because it is a predecessor job to another external job or because a conditional dependency is defined.
The request is rejected.
Submit another occurrence of the predecessor job without the dependency.
EQQA645E
HTTP REQUEST COULD NOT BE FULFILLED.
An HTTP request was made by the controller to the agent or broker, but the request could not be fulfilled. A possible cause for this problem is that the version of the agent or dynamic workload broker might not be compatible with the request.
The request is rejected.
Verify the version of the agent or dynamic workload broker to ensure it is compatible with the request and then submit the request again.
EQQA700E
Is mandatory must be C, P or N.
An incorrect value was set for the Is mandatory
field in the Application Description panel. This field specifies
if an external dependency must be resolved immediately (at plan
level), later (after waiting for a subsequent predecessor add)
or if it can be left unresolved. Allowed values are C (control),
P (plan), or N (no).
The ISPF panel is displayed again.
Specify a valid value.
EQQA701E
Criteria must be C, S, R or A.
An incorrect value was set for the Criteria field in
the Application Description panel. Allowed values are C (Closest
Preceding criteria), S (Same Day criteria), R (Relative Interval
criteria), or A (Absolute interval criteria).
The ISPF panel is displayed again.
Specify a valid value.
EQQA702E
From hours must be blank or numeric: range is 0-167.
An incorrect value was set for the From hours field
in the Application Description panel. This field is related to
the resolution criteria used to resolve the dependency: it
specifies the number of hours before of after the Input Arrival
time (as specified in the when field) at
which the interval must start.
The ISPF panel is displayed again.
Specify a valid value.
EQQA703E
From minutes must be blank or numeric: range is 0-59.
An incorrect value was set for the From minutes
field in the Application Description panel. This field is
related to the resolution criteria used to resolve the
dependency: it specifies the number of minutes before of after
the Input Arrival time (as specified in the when field) at
which the interval must start
The ISPF panel is displayed again.
Specify a valid value.
EQQA704E
For days must be numeric: range is 0-7
An incorrect value was set for the For days field in
the Application Description panel. This field is related to the
resolution criteria used to resolve the dependency: it specifies
the number of days one can move back or forward to solve the
dependency.
The ISPF panel is displayed again.
Specify a valid value.
EQQA705E
To hours must be numeric: range is 0-167
An incorrect value was set for the To hours field in
the Application Description panel. This field is related to the
resolution criteria used to resolve the dependency, it specifies
the number of hours before of after the Input Arrival time (as
specified in the when field) at which the interval must end.
The ISPF panel is displayed again.
Specify a valid value.
EQQA706E
To minutes must be numeric: range is 0-59
An incorrect value was set for the To minutes field
in the Application Description panel. This field is related to
the resolution criteria used to resolve the dependency: it
specifies the number of minutes before or after the Input
Arrival time (as specified in the when field) at
which the interval must end.
The ISPF panel is displayed again.
Specify a valid value.
EQQA707E
Time format must be HH.MM
An incorrect value was set for the Time field in the
Application Description panel. This field is related to the
resolution criteria used to resolve the dependency: it specifies
the time before of after the Input Arrival time (as specified in
the when field)
at which the interval must end/start.
The ISPF panel is displayed again.
Specify a valid value.
EQQA708E
When must be B or A.
An incorrect value was set for the when field in the
Application Description panel. This field is related to the
resolution criteria used to resolve the dependency: it can refer
to the start or end of the interval where the dependency must be
solved and specify if one must search before (B) of after (A)
the IA of the occurrence to be added.
The ISPF panel is displayed again.
Specify a valid value.
EQQA709E
From fields must be all blank or all filled up.
Some required values are missing in the From fields of
the Application Description panel. These fields are related to
the resolution criteria to be applied; they can be either left
all blank to indicate that there is no limit in searching a
match before the IA of the occurrence to be added, or all set to
a specific value.
The ISPF panel is displayed again.
Either specify a valid value in every From field of the
panel or leave them all blank.
EQQA714E
From time must be numeric: range is 00:00-23:59
An incorrect value was set for the From
time field in the Application Description panel
This field is related to the resolution criteria used to resolve
the dependency: it specifies the time before or after the IA
time (as specified in the When field) from
which the interval must start.
The ISPF panel is displayed again.
Specify a valid value.
EQQA715E
To time must be numeric: range is 00:00-23:59
An incorrect value was set for the To
time field in the Application Description panel
This field is related to the resolution criteria used to resolve
the dependency: it specifies the time before or after the IA
time (as specified in the When field) from
which the interval must end.
The ISPF panel is displayed again.
Specify a valid value.
EQQA716E
Rem. eng. supports only matching criteria C. DEPT is not run.
The DEPT command cannot be run because the version of the remote engine supports only the default matching criteria C.
The request is rejected, and the value C is applied by default as the matching criteria.
None.
EQQA717W
The remote engine might support only matching criteria C.
Because the remote engine cannot be reached, its version cannot be verified. It might support only the matching criteria C.
None.
None.