EQQK000 - EQQK457
EQQK000E
VALID-TO SPECIFICATION PRECEDES VALID-FROM SPECIFICATION
The valid-to date must be later than the valid-from date.
None.
Specify a correct value and press Enter.
EQQK001E
OI ALREADY EXISTS IN OI DATA BASE
You have attempted to create an operator instruction (OI) that already exists in the OI database.
The system waits for you to respond.
Exit and use the modify function instead of the create function.
EQQK002E
VALIDITY PERIODS OF TEMPORARY OIS MUST NOT OVERLAP
There is an existing operator instruction (OI) whose validity period overlaps with this temporary OI. The validity period of a temporary OI is defined by a valid-from and valid-to specification. The validity periods of temporary OIs must not overlap each other.
The system waits for you to respond.
Respecify valid-from and valid-to period limits.
EQQK003E
OPERATOR INSTRUCTION NOT FOUND IN OI DATA BASE. REFRESH YOUR LIST
You have attempted to browse, modify, or delete an operator instruction (OI) that no longer exists in the OI database. Most likely, the OI has been deleted by another user after your list of OIs was created.
The system waits for you to respond.
Return to the selection panel, create a new list of OIs, and continue your work.
EQQK004W
OPERATOR INSTRUCTION IS IN USE BY USER USR, TRY LATER
Another user is currently updating the same operator instruction.
The system waits for you to respond.
Try again later.
EQQK007E
YOU ARE NOT AUTHORIZED TO ACCESS THE OI DATA BASE
You have attempted to access the operator instruction (OI) database, but you are not authorized to access it.
The system waits for you to respond.
Contact your security administrator.
EQQK008E
YOU ARE NOT AUTHORIZED TO UPDATE THE OI DATA BASE
You have attempted to update the operator instruction (OI) database, but you are not authorized to update it.
The system waits for you to respond.
Contact your security administrator.
EQQK021E
BOTH DATE AND TIME MUST BE SPECIFIED, OR BOTH BLANK
See text.
None.
Specify a value both for date and time, or leave them blank and press Enter.
EQQK022E
THE INPUT FIELD MUST BE ALL NUMERIC, OR BLANK
See text.
None.
Specify a correct value and press Enter.
EQQK023W
THE OPERATOR INSTRUCTION CONTAINS NO TEXT
The operator instruction (OI) that you selected does not contain any text.
The system waits for you to respond.
If this OI should contain text, use the Operator Instruction dialog to add the desired text.
EQQK024W
IT IS NOT POSSIBLE TO SAVE AN OPERATOR INSTRUCTION WITHOUT TEXT
An operator instruction must have a minimum of one line of text.
The system waits for you to respond.
Make sure that there is a minimum of one line of text or issue the CANCEL command to terminate the CREATE, COPY, or MODIFY request.
EQQK025I
THE OI WAS MODIFIED IN THE OI DATA BASE
The operator instruction (OI) record was modified and the OI database was updated.
None.
None.
EQQK026E
INVALID PARAMETERS PASSED TO THE MODULE
The parameters passed to the module from the ISPF panels were invalid. This is an internal HCL Workload Automation for Z error.
The system waits for you to respond.
Contact the Software Support.
Contact your system programmer.
EQQK027I
THE OI WAS ADDED TO THE OI DATA BASE
The operator instruction (OI) record was added to the OI database.
None.
None.
EQQK028I
THE OI WAS NOT MODIFIED IN THE OI DATA BASE
The operator instruction (OI) record in the OI database was not updated, either because you canceled your modify request or because no lines existed in the OI record that you attempted to store.
None.
None.
EQQK029E
THE UPDATE TO THE OI DATA BASE FAILED
The operator instruction (OI) record was modifed, but the OI database has not been updated due to a severe error.
The OI database is not updated.
Try to locate the previous error messages in the message log and contact your system programmer.
EQQK030I
THE OI WAS NOT ADDED TO THE OI DATA BASE
No operator instruction (OI) record was added to the OI database, either because you canceled your create request or because no lines existed in the OI record that you attempted to add.
None.
None.
EQQK031E
APPLICATION IDENTIFICATION MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQK032E
THE NAME DOES NOT START WITH AN ALPHABETIC CHARACTER
See text.
None.
Specify a value and press Enter.
EQQK033E
THE OPERATION NUMBER MUST BE IN THE RANGE 1 - 255
See text.
None.
Specify a correct value and press Enter.
EQQK034E
THE NAME CONTAINS INVALID CHARACTER(S)
A name can be made up of the following valid characters: A through Z, 0 through 9, and national characters (that is, #, $, and @).
None.
Specify a correct value and press Enter.
EQQK035E
BOTH VALID-FROM AND VALID-TO REQUIRED FOR TEMPORARY OIS
Both a valid-from date and a valid-to date are required when creating temporary operator instructions (OIs).
None.
Specify a correct value and press Enter.
EQQK036E
THE OPERATION NUMBER CONTAINS A NON-NUMERIC CHARACTER
The operation number must be numeric.
None.
Specify a correct value and press Enter.
EQQK037E
THE OPERATION NUMBER MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQK038E
TIME MISSING IN VALID-FROM OR VALID-TO SPECIFICATION
Both date and time are required when specifying a valid-from or a valid-to date.
None.
Specify a correct value and press Enter.
EQQK039E
DATE MISSING IN VALID-FROM OR VALID-TO SPECIFICATION
Both date and time are required when specifying a valid-from or a valid-to date.
None.
Specify a correct value and press Enter.
EQQK040I
OI WAS DELETED FROM OI DATA BASE - REQUEST CONFIRMED
The operator instruction (OI) that you selected was deleted from the OI database, as specified.
None.
None.
EQQK041I
OI NOT DELETED FROM OI DATA BASE - REQUEST NOT CONFIRMED
The operator instruction (OI) that you selected was not deleted from the OI database. The initial request was not confirmed.
None.
None.
EQQK042E
OI DELETE REQUEST FAILED DUE TO I/O ERROR
The operator instruction (OI) record was deleted, but the OI database has not been updated due to a severe error.
The OI database is not updated.
Try to locate the previous error messages in the message log and contact your system programmer.
EQQK043E
THE WORK STATION NAME MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQK044I
NO OPERATOR INSTRUCTION MATCHED YOUR SELECTION CRITERIA
No operator instructions matched the selection criteria that you specified.
None.
None.
EQQK050E
A REMOVAL DATE FOR PURGING OLD TEMPORARY OIS MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQK051I
PRESS ENTER TO CREATE REMOVAL JCL, OR END TO CANCEL
You have requested to create JCL for a job to remove operator instructions. You must press ENTER to generate the JCL or enter the END command to cancel your request.
The system waits for you to respond.
Press ENTER or the End PF-key (or enter the END command).
EQQK052E
A VALID DATA SET NAME MUST BE SPECIFIED
See text.
None.
Specify a correct value and press Enter.
EQQK053E
REPLY MUST BE Y OR N
See text.
None.
Specify a correct value and press Enter.
EQQK054I
PRESS ENTER TO CREATE UPDATE JCL, OR END TO CANCEL REQUEST
You have requested to create JCL for a job to mass update operator instructions. You must press ENTER to generate the JCL or enter the END command to cancel your request.
The system waits for you to respond.
Press ENTER or the End PF-key (or enter the END command).
EQQK450E
THE APPLICATION DESCRIPTION AD DOES NOT EXIST
When attempting to create or modify an operarator instruction (OI), the OI data is checked for validity. A check is made for the corresponding operation. The validation failed because the application description AD does not exist.
The system waits for you to respond.
Correct the application ID and save the OI.
EQQK455E
APPLICATION DESCRIPTION AD HAS NO WORK STATION WS
When attempting to create or modify an operator instruction (OI), the OI data is checked for validity. A check is made for the corresponding operation. The validation failed because the application description AD has no workstation WS.
The system waits for you to respond.
Correct the workstation name and save the OI.
EQQK456E
APPLICATION DESCRIPTION AD HAS NO OPERATION OP
When attempting to create or modify an operator instruction (OI), the OI data is checked for validity. A check is made for the corresponding operation. The validation failed because the application description AD has no operation OP.
The system waits for you to respond.
Correct the operation number and save the OI.
EQQK457E
APPLICATION DESCRIPTION AD HAS NO OPERATION WS OP
When attempting to create or modify an operator instruction (OI), the OI data is checked for validity. A check is made for the corresponding operation. The validation failed because the application description AD has no operation WSOP.
The system waits for you to respond.
Correct the operation number and save the OI.