EQQJ001 - EQQJ820

EQQJ001I

ETT ACTIVATION/DEACTIVATION REQUEST WAS NOT CONFIRMED

You chose not to confirm the original request. So it was ignored by HCL Workload Automation for Z.

None.

None.

EQQJ002W

ETT ACTIVATION REQUEST IGNORED SINCE ETT ALREADY ACTIVE

The event-triggered tracking (ETT) function was already active when you requested activation of the function.

None.

None.

EQQJ003W

ETT DEACTIVATION REQUEST IGNORED SINCE ETT NOT ACTIVE

The event-triggered tracking (ETT) function was not active when you requested deactivation of the function.

None.

None.

EQQJ004I

ETT FUNCTION HAS BEEN SUCCESSFULLY ACTIVATED

The event-triggered tracking (ETT) activation request has been successfully processed.

None.

None.

EQQJ005I

ETT FUNCTION HAS BEEN SUCCESSFULLY DEACTIVATED

The event-triggered tracking (ETT) deactivation request has been successfully processed.

None.

None.

EQQJ006W

ETT REQUEST IGNORED DUE TO LACK OF PROPER AUTHORIZATION

You have attempted to use the event-triggered tracking (ETT) function, but you do not have the necessary authorization.

None.

Contact your HCL Workload Automation for Z security administrator.

EQQJ007E

NOT AUTHORIZED TO UPDATE ENTRY ETTENAME

You have attempted to update the event-triggered tracking (ett) entry ETTENAME, but you do not have the necessary authorization.

The request is rejected.

Contact your security administrator.

EQQJ010I

YOUR CHANGES HAVE SUCCESSFULLY UPDATED THE ETT DATABASE

Your modifications to the event-triggered tracking (ETT) table have successfully updated the ETT database.

None.

None.

EQQJ011E

YOUR CHANGES DID NOT UPDATE THE ETT DATABASE DUE TO ERRORS

Your modifications to the event-triggered tracking (ETT) table did not update the table data set due to some error in the HCL Workload Automation for Z subsystem.

None.

Review the HCL Workload Automation for Z message log for I/O errors pertaining to the table data set. Correct all errors and restart HCL Workload Automation for Z.

Exit from this panel and reenter it to determine which modifications updated the ETT database. Reenter those modifications that did not take effect. If the error persist, contact your system programmer.

EQQJ012E

YOUR CHANGES TO THE ETT CRITERIA CONTAIN SYNTAX ERROR(S)

Your changes to the event-triggered tracking (ETT) criteria contain a syntax error (or errors).

None.

Enter the correct data.

EQQJ013E

THE ETT CRITERIA IS BEING UPDATED BY USER USER - TRY LATER

Another user is currently updating the event-triggered tracking (ETT) criteria table. Only one user can access the table at a time.

None.

Try again later.

EQQJ014E

VALID MATCHING TYPES ARE OCHCEXA, OCHCPFX AND OCHCSFX

OCHCEXA, OCHCPFX and OCHCSFX are the national language characters for 'E' (exact), 'P' (prefix) and 'S' (suffix).

None.

Enter the correct matching type.

EQQJ020E

AVAILABILITY STATUS CHANGE INFO MUST BE SPECIFIED FOR RESOURCE EVENTS

You have defined a triggering event as a resource event, but failed to indicate if event-triggered tracking (ETT) triggering should occur only for an availability status switch from N (no) to Y (yes) or if ETT triggering should occur whenever the availability is set to Y.

The system waits for you to respond.

If you want the ETT triggered application to be added only when the resource is switched from unavailable to available, specify Y in the availability switch field. If you want the application to be added every time that the resource is set to available, regardless of the old status, specify N in the availability switch field.

EQQJ021E

ETT EVENT TYPE MUST BE OCHCJOB OR OCHCRES

OCHCJOB and OCHCRES are the national language characters for 'J' (job) and 'R' (resource).

The system waits for you to respond.

Enter the correct data.

EQQJ022E

JOB NAME REPLACEMENT INFO MUST BE SPECIFIED FOR JOB EVENTS

You have specified the event to be a job event, but failed to indicate whether the job name in the first operation of the added application should be replaced or not.

The system waits for you to respond.

Enter the correct data.

EQQJ023E

JOB NAME REPLACEMENT INFO MUST BE OCHCYES OR OCHCNO

OCHCYES and OCHCNO are the national characters for 'Y' (yes) and 'N' (no).

The system waits for you to respond.

Enter the correct data.

EQQJ024E

JOB NAME REPLACEMENT INFO MUST BE OCHCNO OR BLANK FOR RESOURCE EVENT

You have specified the event to be a resource event. You cannot replace job name information for resource events. HCL Workload Automation for Z automatically sets this information to N (no) for resource events.

OCHCNO is the national character for 'N' (no).

None.

Enter the OCHCNO or blank for resource events and submit the operation again.

EQQJ025E

A VALID NAME OF AN ASSOCIATED APPLICATION MUST BE SPECIFIED

You must specify the name of a valid application to be added to the current plan when an event-triggered tracking (ETT) event matching this criteria entry occurs.

The system waits for you to respond.

Enter correct data.

EQQJ026E

VALID VALUES ARE: OCHCYES, OCHCNO, OCHPRED, OCHSUCC AND BLANK

You have entered a value for the dependency resolution attribute that is not recognized by the Event-Triggered Tracking dialog. You must change the value to one of the supported values defined by this message.

The system waits for you to respond.

Change the dependency resolution value.

EQQJ027E

AVAILABILITY STATUS CHANGE FIELD IS NOT OCHCNO OR BLANK

You have defined a triggering event as a reader event, but have specified a character other than OCHCNO or blank in the availablility switch field. The availability status switch is relevant only when the triggering event is a resource.

The system waits for you to respond.

Change the availability switch indicator for the trigger to OCHCNO or leave the field blank.

EQQJ028E

EACH ETT CRITERIA ROW MUST HAVE A UNIQUE EVENT NAME WITHIN TYPE

You have specified duplicate event names in the event-triggered tracking (ETT) table.

The system waits for you to respond.

Remove the duplicate entry or make its name unique.

EQQJ029E

AVAILABILITY STATUS CHANGE FIELD IS NOT OCHCYES OR OCHCNO

You have defined a triggering event as a resource event, but have specified a character other than OCHCYES or OCHCNO in the availablility switch field. The availability status switch must be set when the triggering event is a resource.

The system waits for you to respond.

If you want the event-triggered tracking (ETT) application to be added only when the resource is switched from unavailable to available, specify Y in the availability switch field. If you want the application to be added every time the resource is set to available, regardless of the old status, specify N in the availability switch field.

EQQJ500E

INVALID STRING IN DIRECTIVE AT LINE LINE OF SCTN

The predicate for any keyword other than COMP must:
  • Consist of alphanumeric characters
  • Begin with an alphabetic character.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the tailoring directive.

EQQJ501E

DUPLICATE TABLE NAME TBL AT LINE LINE OF SCTN

The same table name was encountered twice in a SEARCH directive of the product.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the tailoring directive.

EQQJ502E

CONTRADICTORY USE OF STANDARD TABLES AT LINE LINE OF SCTN

A SEARCH directive of the product contains either both GLOBAL and NOGLOBAL, or both APPL and NOAPPL.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the tailoring directive.

EQQJ503E

ERROR ATTEMPTING TO READ JCL MEMBER MBR

The member specified in a FETCH directive of the product could not be found. The member name is incorrect or the member cannot be accessed.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the tailoring directive or ensure that the member is available.

EQQJ504E

KEYWORD STRING TOO LONG IN DIRECTIVE BEGINNING AT LINE LINE OF SCTN

The third and final string in a directive of the product contains more than 1024 characters after substitution, including continuation lines.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the tailoring directive.

EQQJ505E

INVALID KEYWORD COMBINATION IN DIRECTIVE BEGINNING AT LINE LINE OF SCTN

A directive of the product has at one or more of these problems:
  • Keywords are incompatible with each other.
  • Keywords are incompatible with the type of directive.
  • Mandatory keywords are missing.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the tailoring directive.

EQQJ506E

RECURSIVE SUBSTITUTION AT LINE LINE OF SCTN

The value of a variable depends on the values of other variables, which in turn depend on its value. No value can be determined for this variable.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Examine the table definitions of the variables in the line and eliminate the closed translation loop.

EQQJ507E

CHANGE OF STRUCTURE CAUSED BY SUBSTITUTION IN DIRECTIVE BEGINNING AT LINE LINE OF SCTN

Variable substitution has caused one or more of these changes:
  • A directive of the product has been created.
  • The type of a directive of the product has changed.
  • The keywords of a directive of the product have changed.
  • A directive of the product has changed to another line type.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the original tailoring directive or substitution values.

EQQJ508E

RECURSIVE SUBSTITUTION OF LENGTH LINES FROM FROM OF SCTN

A closed loop of dependency definitions or variable translations exists.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Examine the table definitions of the variables in this section, and eliminate the loop.

If this section contains promptable variables, the values supplied for these variables may have caused the error.

EQQJ509E

TABLE TBL NOT FOUND

If TABLE GLOBAL NOT FOUND message text appears: possible reasons are:

The user did not explicitly provide tables to be searched.

The user specified some tables to be searched but none of them are defined in the AD file.

The scheduler tried to search the variable in the global table, but the default global variable table is not defined in the AD file.

If you are scheduling a JCL submission, a system automation command, or a job type with advanced options, the current operation status is set to ended-in-error with error code OJCV. If you are scheduling a not centralized job submission, the Symphony creation or the addition of the operation fails.

Check the directives or the VARSUB statement or the HTTPOPTS statement to ensure that the table names are correct. Use the Variable Definition dialog to ensure that the tables exist.

EQQJ510E

UNSET VARIABLE VAR AT LINE LINE OF SCTN

A non-dependent variable with no value was encountered in the submit phase or in a JCLPREPA simulation request.

In the submit phase, or at simulation, these types of variables can be encountered:
  • Variables that have already been provided with values
  • Variables that are dependent on other variables
  • Variables that do not require a setting (which are eliminated from the job stream).

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Either change the variable definition or give the variable a value.

EQQJ511E

JOB JOBNAME IN APPLICATION APPL CONTAINS A SCHEDULER CONTROL STATEMENT THAT IS NOT RECOGNIZED

The product was unable to submit the identified job because it contains an incorrectly coded //*%OPC statement and JCL variable scanning is active for this job.

The current operation status is set to ended-in-error with error code OJCV.

Locate the JCL for this job and correct the //*%OPC statement. Use the scheduler dialog to rerun the operation.

EQQJ512E

RECURSIVE DEPENDENCY VARIABLE VAR AT LINE LINE OF SCTN

A closed loop of dependency definitions exists.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Examine the table definitions of this variable and the chain on which it is dependent, and eliminate the closed dependency loop. The loop does not necessarily include the variable listed in the message.

EQQJ513E

SETUP VARIABLE CHLD DEPENDENT ON SUBMIT VARIABLE PRNT AT LINE LINE OF SCTN

A prompt variable cannot be dependent on a submit variable.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the table definitions, SEARCH directives, or TABLE directives.

EQQJ514E

RETURN CODE RC FROM USER EXIT USRX. THE EXIT WAS DEFINED FOR VARIABLE VAR IN TABLE TAB FOR APPLICATION ADID, WITH OCCURRENCE INPUT ARRIVAL IAD, IAT. THE OPERATION NUMBER IS OPNO

HCL Workload Automation for Z received an unexpected return code from an exit.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the user module, supply a valid return code, and restart HCL Workload Automation for Z.

EQQJ515E

RECOVERABLE ABEND IN USER EXIT USRX THAT WAS DEFINED FOR VARIABLE VAR IN TABLE TAB FOR APPLICATION ADID, INPUT ARRIVAL IS IAD, IAT, OPERATION NUMBER IS OPNO

The user module caused an abend from which HCL Workload Automation for Z recovered.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the user module and restart HCL Workload Automation for Z.

EQQJ516E

UNRECOVERABLE ABEND IN USER EXIT USRX THAT WAS DEFINED FOR VARIABLE VAR IN TABLE TAB, APPLICATION IS ADID, WITH OCCURRENCE INPUT ARRIVAL IAD, IAT, OPERATION NUMBER IS OPNO

The user module caused an abend from which HCL Workload Automation for Z could not recover.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the user module and restart HCL Workload Automation for Z.

EQQJ517E

INVALID VALUE VAL SUPPLIED BY USER EXIT USRX FOR VARIABLE VAR IN TABLE TAB FOR APPLICATION ADID, OCCURRENCE IA IS IAD, IAT, OPERATION NUMBER IS OPNO

The value that you supplied for the variable violates the verification rules in the variable definition.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the user module or verification criteria. To use the corrected user module, you must restart HCL Workload Automation for Z.

EQQJ518E

THE SUBSTITUTION EXIT USRX WAS REFERENCED BY VARIABLE VAR. THE EXIT WILL NOT BE CALLED AS IT HAS BEEN MARKED NOT EXECUTABLE BY THE SCHEDULER. APPLICATION IS ADID, INPUT ARRIVAL IS: IAD, IAT, AND OPERATION NUMBER IS OPNO

HCL Workload Automation for Z has previously discovered an abend in this exit and marked it as not executable. This exit is not called again.

The current operation status is set to ended-in-error, with error code OJCV.

Correct the exit and restart HCL Workload Automation for Z to reuse the exit.

EQQJ519E

INSUFFICIENT STORAGE TO BUILD JCL RECORD. APPLICATION IS: ADID, OPERATION NO IS: OPNO, INPUT ARRIVAL DATE IS: IAD AND INPUT ARRIVAL TIME IS: IAT.

HCL Workload Automation for Z tried to allocate storage for a final build of the JCL record, but the request for storage failed.

The operation status depends on the SUBFAILACTION keyword in the JTOPTS initialization statement. The operation can:
  • Keep status R or extended status RE
  • Get status C (complete)
  • Get status E (ended-in-error) with error code OSUF.

Make sure that HCL Workload Automation for Z is running in a large enough region and restart HCL Workload Automation for Z.

EQQJ520E

VALUE LENGTH IS REQUIRED WHEN COMPARISON OPERATOR SPECIFIED

Because you entered a comparison operator, you must enter a value length.

The system waits for you to respond.

Enter the correct value.

EQQJ521E

COMPARISON OPERATOR REQUIRED WHEN LENGTH OPERATOR SPECIFIED

Because you entered a value length, you must enter a comparison operator.

The system waits for you to respond.

Enter the correct value.

EQQJ522E

THE DEFAULT VALUE IS INVALID FOR THE VERIFICATION TYPE

The default value that you entered does not match the verification rules for the variable.

The system waits for you to respond.

Enter the correct value.

EQQJ523E

A VALIDATION PATTERN IS REQUIRED FOR PICT VERIFICATION

Because you asked for PICT verification, you must enter a validation pattern.

The system waits for you to respond.

Enter the correct value.

EQQJ524E

Y/N MUST BE ENTERED IN NUMERIC FIELD FOR LIST/RANGE

Because you asked for RANGE verification, you must enter Y (yes) or N (no) in the numeric field.

The system waits for you to respond.

Enter the correct value.

EQQJ525E

THE JCL VARIABLE TABLE HAS BEEN DELETED

The current variable table has been deleted from HCL Workload Automation for Z database.

The table is deleted.

Re-define a variable table if needed, or check the current definition and specify it in any existing concatenation.

EQQJ526E

CHARACTER CHR IN POSITION PDS IS INVALID

The value entered as a default value does not match the validation pattern defined for the variable.

The system waits for you to respond.

Enter the correct value.

EQQJ527E

THE VALUES/RANGES MAY NOT CONTAIN IMBEDDED BLANKS

You cannot use blanks in a LIST/RANGE verification value list.

The system waits for you to respond.

Enter the correct value.

EQQJ528E

THE NUMBER OF VALUES MUST BE EVEN FOR RANGE VERIFICATION

You specified an odd number of values for a range verification.

The system waits for you to respond.

Enter the correct value.

EQQJ529E

THE VALUES DEFINING A RANGE ARE IN DESCENDING SEQUENCE

You entered a range that consists of a larger number followed by a smaller number. You must specify the smaller number (beginning of the range) before the larger number (end of the range).

The system waits for you to respond.

Enter the correct value.

EQQJ530E

SCANNING LENGTH EXCEEDED LINE LINE OF SCTN

Substitution of a JCL command has caused the command length to exceed 71 characters or substitution of an in-stream data line has caused the in-stream data line to exceed 80 characters.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

If the substitution is correct, split the command line over two or more lines. If the problem occurs in an in-stream data line, verify that the ISPF profile option for sequence numbering is turned off in the JCL job library.

EQQJ531E

THE SCHEDULER WAS UNABLE TO LOAD VARIABLE SUBSTITUTION EXIT USRX TABLE NAME IS TAB, VARIABLE NAME IS VAR, APPLICATION IS ADID, OCCURRENCE IA = IAD, IAT, OPERATION NUMBER IS OPNO

A variable substitution exit that was referred to could not be loaded by HCL Workload Automation for Z.

If you are scheduling a JCL job or a centralized script, the current operation status is set to ended-in-error with error code OJCV. If you are scheduling a not centralized job, depending on where you are, Batch or controller:
  • The creation of symphony continues but the job is added in fail status.
  • The addition of the operation fails.

Check the current load library in the started task JCL and make sure that the exit is link-edited to the correct library.

EQQJ532E

INVALID EXPRESSION EXPR BEGINNING AT LINE LINE OF SCTN

The expression must consist of keyword= where keyword is one of: NAME, ACTION, PHASE, MEMBER, COMP, EXIT.

This message can also be issued if all mandatory keywords have not been specified.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL.

EQQJ533E

DIRECTIVE DIR OUT OF POSITION LINE LINE OF SCTN

There are two possibilities:
  • No previous //*%OPC BEGIN directive corresponds to the current //*%OPC END directive.
  • A //*%OPC BEGIN directive was found previously, but the current directive is not the corresponding //*%OPC END directive.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL.

EQQJ534E

INVALID VARIABLE VAR LINE LINE OF SCTN

The name of a variable can contain one to eight alphanumeric characters, where the first character is alphabetic. This message can also be reported if a tabular variable, that is, a ?-variable, does not include the substitution column position and a default position is not defined in the JCL variable table.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL or the JCL variable table as appropriate.

EQQJ535E

UNDEFINED VARIABLE VAR LINE LINE OF SCTN

A variable that is not predefined by HCL Workload Automation for Z must appear in a table that is created by the JCL variable dialog and is included in the current table concatenation.

For more information, refer to the description of the SEARCH and TABLE directives in Managing the Workload.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL.

EQQJ536E

POSITIONAL OVERLAP VARIABLE VAR LINE LINE OF SCTN

The tabular variable (?-variable) cannot be assigned the positions specified in the prefix or by default because part or all of the receiving string is already occupied.

For more information, refer to Managing the Workload.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL.

EQQJ537E

CALENDAR CAL CANNOT BE FOUND. SUBSTITUTION FAILED

During variable substitution of a job, a function that requires access to a calendar, for example, a SETVAR directive asking for an expression involving arithmetics on calendar days, could not be processed. The calendar referenced by the occurrence no longer exists.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

The calendar may have been deleted by mistake. Delete the SETVAR directive from the JCL, find out what the calendar once looked like and insert the needed date manually under JCL Edit.

EQQJ538E

BEGIN ACTION NOT CLOSED LINE LINE OF SCTN

At the end of the JCL stream, the last //*%OPC BEGIN command has not been closed by a //*%OPC END command.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL.

EQQJ539E

VARIABLE SUBSTITUTION WAS INTERRUPTED BY SUBSTITUTION EXIT USRX. APPLICATION IS ADID, INPUT ARRIVAL DATE AND TIME IS IAD, IAT OPERATION NUMBER IS OPNO

A substitution exit set a return code of 8, which interrupted the JCL variable substitution. No further substitution is done for this operation.

If you are scheduling a JCL submission, the current operation status is set to ended-in-error with error code OJCV. If you are scheduling a not centralized job submission, the symphony creation or the addition of the operation fails.

Check the current exits and determine the reason for return code 8 being passed back. If the exit is changed and you want to reuse it, restart HCL Workload Automation for Z. If you are scheduling a system automation command, the operation status is set to ended-in-error with error code OJCV.

EQQJ540E

MORE THAN 16 TABLES DECLARED IN SEARCH DIRECTIVE AT LINE LINE OF SCTN

The number of tables requested by a SEARCH directive is greater than 16.

Unless GLOBAL and APPL are explicitly excluded (NOGLOBAL and NOAPPL), they contribute to the total even if they are not specified in the SEARCH directive.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Check if all tables are necessary and correct the JCL.

EQQJ541E

ATTEMPT TO CONCATENATE MORE THAN 16 TABLES BY TABLE DIRECTIVE AT LINE LINE OF SCTN

A TABLE directive has been encountered when 16 tables are already active.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Check if all tables are necessary and correct the JCL.

EQQJ542E

COMP EXPRESSION BEGINNING AT LINE LINE OF SCTN EXCEEDS 1024 BYTES

The total length of all fields of a COMP expression, including COMP= and all continuations of the right side of the expression on subsequent JCL lines, cannot exceed 1024 characters after substitution.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL.

EQQJ543E

COMP EXPRESSION BEGINNING AT LINE LINE OF SCTN IS NOT WELL FORMED: EXPR

The syntax of the COMP keyword is not correct.

The current operation status is set to ended-in-error with error code OJCV.

Correct the directive of the product using the current COMP keyword.

This message is followed by message EQQJ544E, EQQJ545E, EQQJ546E, EQQJ572E, EQQJ573E, or EQQJ547E, which describes the exact cause of the syntax error.

EQQJ544E

COMP EXPRESSION CONTAINS UNBALANCED PARENTHESIS

Parentheses are not used correctly in the COMP keyword.

The current operation status is set to ended-in-error with error code OJCV.

Correct the JCL for the operation and make sure that the COMP keyword contains the correct number of parentheses.

This message is issued together with message EQQJ543E. For an explanation of the COMP keyword, refer to Managing the Workload

EQQJ545E

COMP EXPRESSION MUST CONTAIN AT LEAST ONE OPERATOR

The COMP keyword does not contain any operators.

The current operation status is set to ended-in-error with error code OJCV.

Correct the JCL for the operation and make sure that the COMP keyword contains at least one operator.

This message is issued together with message EQQJ543E. For an explanation of the COMP keyword, refer to Managing the Workload

EQQJ546E

COMP EXPRESSION CONTAINS TOO FEW EQUATION SEPARATING COMMAS

At least one comma is missing in the COMP keyword.

The current operation status is set to ended-in-error with error code OJCV.

Correct the JCL for the operation and make sure that the COMP keyword is correct.

This message is issued together with message EQQJ543E. For an explanation of the COMP keyword, refer to Managing the Workload

EQQJ547E

COMP EXPRESSION CONTAINS TOO FEW OPERATORS

At least one operator is missing in the COMP keyword.

The current operation status is set to ended-in-error with error code OJCV.

Correct the JCL for the operation and make sure that the COMP keyword is correct.

This message is issued together with message EQQJ543E. For an explanation of the COMP keyword, refer to Managing the Workload

EQQJ548W

VARIABLE VAR IN TABLE TABLE COULD NOT BE UPDATED. REASON IS RSN

A SAVEVAR directive with ERRORACT=CONT was found during variable substitution. HCL Workload Automation for Z tried to update the default value as requested in the SETVAR directive, but it was not possible for one of the following reasons:
HELDLOCK
Could not get ENQ lock necessary to access the variable.
NOTFOUND
Variable/table did not exist in the table data set
BADVNAME
Variable/table is either a HCL Workload Automation for Z-supplied variable or a temporary variable. These variables are never saved.

Processing continues. The job is submitted as normal, but the next time that the default value is requested as input to variable substitution, it does not show the latest updated value.

The value can be corrected by allowing a person with update access to the variable table to update the default value manually in the JCL variable dialog.

EQQJ549E

A SETUP PHASE DIRECTIVE AT LINE LINE OF SCTN REFERS TO A VARIABLE DEFINED FOR USE AT SUBMIT

The current job contains a JCL processing directive specifying PHASE=SETUP. HCL Workload Automation for Z could not determine what action is requested by the statement because it refers to a JCL variable whose value is not determined until the submit phase.

The system waits for you to respond.

Enter the JCL Edit dialog and correct the incorrect statement. Reenter the Ready List dialog and retry JCL setup for this operation.

EQQJ550E

CHARACTER CHR IN POSITION POS IS INVALID

The value entered as a default value does not match the validation pattern defined for the variable.

The system waits for you to respond.

Enter the correct value.

EQQJ551E

THE VALUE OF THE INDEPENDENT VARIABLE ALREADY EXISTS

The same value of the independent variable is given in two different rows of the dependency table.

The system waits for you to respond.

Correct or delete the values that you entered.

EQQJ553E

VALIDATION ERROR AT LINE LINE in JOB SCTN VALUE IS REQUIRED FOR THE VARIABLE VAR BUT IS DEFINED AS BLANK

JCL tailoring is setting a temporary variable by a replacement with a source string. This string is blank, but a value is required.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCLV. Otherwise, the status is not changed.

Check the SETVAR directive from JCL to find the cause of the error and use JCL Edit for manual insertion of the missing value.

EQQJ560E

MORE THAN 16 VARIABLES SPECIFIED IN SAVEVAR DIRECTIVE AT LINE LINE OF SCTN

The number of variables requested to be saved in a SAVEVAR directive is greater than 16.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Split the SAVEVAR directive into multiple directives.

EQQJ561E

TEMPORARY VARIABLE NAME VAR ALREADY USED FOR SUBSTITUTION IN JOB JOBNAME

A SETVAR directive requests creation of a temporary variable. There has been an earlier reference in the job to the same name and it has been found in the HCL Workload Automation for Z Variable Table.

If the error occurs during submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Use another name for your temporary variable.

EQQJ562E

INSUFFICIENT STORAGE TO PROCESS MEMBER MEMBER OF DDNAME

HCL Workload Automation for Z was attempting to build a record in the VSAM data set to be inserted in the JCL repository data set, but it was unable to do so because of insufficient virtual storage.

The operation remains in Ready status. HCL Workload Automation for Z is unable to submit the job to JES.

Stop HCL Workload Automation for Z and restart it in a larger region.

Submit the job manually.

EQQJ563E

THE SCHEDULER WAS UNABLE TO FIND MEMBER MEMBER IN DDNAME LIBRARY FILE

HCL Workload Automation for Z was attempting to submit a job to JES for a ready operation on a computer workstation. However, no JCL for this operation is saved in the JCL repository data set and the job is not present as a member in the library defined by the EQQJBLIB DD statement.

The operation remains in Ready status. HCL Workload Automation for Z assumes that some other function submits the job to JES.

If necessary, submit the job manually.

Check that the EQQJBLIB DD statement is correctly defined and that all required members are defined.

EQQJ564W

MEMBER MEMBER IN DDNAME LIBRARY FILE IS EMPTY

The JCL library member exists in the library defined by the EQQJBLIB DD statement, but there are no records in the member.

The operation remains in Ready status. HCL Workload Automation for Z assumes that some other function submits the job to JES.

If necessary, submit the job manually.

Check that the EQQJBLIB DD statement is correctly defined and that all required members are defined.

EQQJ565E

INVALID VARIABLE OR TABLE NAME AT LINE LINE OF SCTN

During variable substitution of a job, a SAVEVAR directive specified the name of a variable, or a variable table, with incorrect syntax.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the syntax of the variable or variable table.

EQQJ566E

INVALID REFERENCE TO GLOBAL TABLE AT LINE LINE OF SCTN

During variable substitution of a job, a SAVEVAR directive was found that specified only the variable name. The implied table is then the Variable Substitution global table. However, no GTABLE keyword has been specified in OPCOPTS.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Either add a GTABLE keyword to OPCOPTS and restart the controller or specify the variable table in the SAVEVAR statement.

EQQJ567E

THE JCL FOR APPLICATION AD COULD NOT BE INSERTED IN THE JS REPOSITORY PHYSICAL RECORD SIZE IS TOO SMALL

The physical record length specified for the JS repository is too small.

The current operation remains in Ready status.

Increase the physical record length for EQQJS1DS and EQQJS2DS.

Contact your system programmer.

Check the VSAM definitions for EQQJS1DS and EQQJS2DS.

EQQJ568E

VARIABLE VAR IN TABLE TABLE COULD NOT BE UPDATED. REASON: RSN

A SAVEVAR directive with ERRORACT=NOCONT was found during variable substitution. HCL Workload Automation for Z tried to update the default value as requested in the SETVAR directive, but it was not possible for one of the following reasons:
HELDLOCK
Could not get ENQ lock necessary to access the variable.
NOTFOUND
Variable/table did not exist in the variable table data set
BADVNAME
Variable/table is either a HCL Workload Automation for Z-supplied variable or a temporary variable. These variables are never saved.

The value can be corrected by allowing a person with update access to the variable table to correct the default value manually in the JCL variable table dialog.

EQQJ569E

INVALID REFERENCE TO DYNAMIC FORMAT VARIABLE AT LINE LINE OF SCTN

A reference to a dynamic-format variable has been found and the format of the variable has not been set in a SETFORM directive.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Insert a SETFORM directive in the JCL earlier than the point where it is referenced.

EQQJ570E

INVALID DYNAMIC FORMAT VARIABLE NAME AT LINE LINE OF SCTN

During variable substitution of a job, a SETFORM directive was found where the name of the dynamic-format variable is not a HCL Workload Automation for Z-supplied dynamic format variable.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the variable name in the SETFORM directive.

EQQJ571E

INVALID FORMAT EXPRESSION IN SETFORM DIRECTIVE AT LINE LINE OF SCTN

During variable substitution of a job, a SETFORM directive was found where the format did not have the proper syntax. Possible errors are:
  • The first characters after the left parenthesis and the last characters before the right parenthesis of the expression are not meaningful keywords for the specified dynamic format variable. (For example, CCYY, YY, MM, DD, or DDD for a date-related dynamic variable.)
  • The whole format expression was searched and no meaningful keywords for the specified dynamic-format variable were found. (For example, CCYY, YY, MM, DD, or DDD was not found for a date-related dynamic variable.)
  • HCL Workload Automation for Z variable substitution characters (&, %, = or ?) are found in the expression.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the format expression in the SETFORM directive.

EQQJ572E

COMP EXPRESSION CONTAINS MULTIPLE VALUES FOR 'EXPRESSION2'

A COMP expression with operators GT, GE, LT, or LE only allows one value for expression2.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL for the operation and make sure that the COMP keyword is correct.

EQQJ573E

COMP EXPRESSION CONTAINS GENERIC SEARCH CHARACTERS

A COMP expression with operators GT, GE, LT, or LE does not allow the generic characters * or % in expression2.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the JCL for the operation and make sure that the COMP keyword is correct.

EQQJ575E

ARITHMETIC EXPRESSION BEGINNING AT LINE LINE OF SCTN EXCEEDS LIMITS

During variable substitution of a job, the calculation of a SETVAR arithmetic expression resulted in a date value that exceeds HCL Workload Automation for Z limits. HCL Workload Automation for Z supports dates from 1 January 1984 to 31 December 2071. If the expression includes dynamic-format supplied variables containing the first or the last day in the month or in the year of the occurrence IA, the calculated date must fall within the range of four years earlier and seven years later than the current year.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the SETVAR arithmetic expression.

EQQJ576E

THE EQQUX002 EXIT COULD NOT OPEN AN INPUT DATA SET TO READ JOB MEMBER EXIT MESSAGE IS: UX002MSG

The joblib I/O exit was called and gave a return code indicating that it could not open one of its input data sets.

The job is not submitted by HCL Workload Automation for Z as intended. The operation remains in Ready status.

Correct all errors and restart HCL Workload Automation for Z.

If necessary, submit the job manually.

Check that all DD statements needed by the EQQUX002 exit have been correctly defined and that the HCL Workload Automation for Z started task has (as a minimum) read access to all referenced data sets.

EQQJ577E

INSUFFICIENT STORAGE TO PROCESS JOB MEMBER FOR EQQUX002 EXIT

HCL Workload Automation for Z was building a reord in the VSAM data set to be inserted in the JCL repository data set, but it was unable to do so because of insufficient virtual storage.

The operation remains in Ready status. HCL Workload Automation for Z is unable to submit the job to JES.

Stop HCL Workload Automation for Z and restart it in a larger region.

Submit the job manually.

EQQJ578E

THE EQQUX002 EXIT COULD NOT FIND JOB MEMBER IN ANY INPUT DATA SET

HCL Workload Automation for Z was attempting to submit a job to JES for a ready operation on a computer workstation. However, no JCL for this operation is saved in the JCL repository data set, and the joblib I/O exit could not find the job in any input data set.

The operation remains in Ready status. HCL Workload Automation for Z assumes that some other function submits the job to JES.

Correct all errors and restart HCL Workload Automation for Z.

If necessary, submit the job manually.

Check that all DD statements needed by the EQQUX002 exit have been correctly defined and that all required members are defined.

EQQJ579W

THE EQQUX002 EXIT DID NOT RETURN ANY DATA FOR JOB MEMBER

The joblib I/O exit was called to retrieve a job to be submitted, but the exit did not return any data.

The job is not submitted by HCL Workload Automation for Z as intended. The operation remains in Ready status.

Correct all errors and restart HCL Workload Automation for Z.

If necessary, submit the job manually.

Check that the joblib I/O exit has been correctly installed and that it works correctly.

EQQJ580E

THE EQQUX002 EXIT RETURNED THE FOLLOWING I/O ERROR MESSAGE FOR JOB MEMBER: UX002MSG

The joblib I/O exit was called to retrieve a job to be submitted, but the exit gave a return code indicating that an I/O error had occurred on an input data set.

The job is not submitted by HCL Workload Automation for Z as intended. The operation remains in Ready status.

Correct all errors and restart HCL Workload Automation for Z.

If necessary, submit the job manually.

Check that the joblib I/O exit can access all required input data sets and that it works correctly.

EQQJ581E

INVALID TEMPORARY VARIABLE NAME AT LINE LINE OF SCTN

During variable substitution of a job, a SETVAR directive was found where the name of the temporary variable is incorrect. The possible errors are: termwidth=

  • The variable name does not start with a T.
  • The rest of the variable name contains one or more characters that are not alphanumeric.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the name of the temporary variable.

EQQJ582E

JOB MEMBER RETURNED BY THE EQQUX002 EXIT EXCEEDS MAXIMUM SUPPORTED SIZE

The joblib I/O exit was called to retrieve a job to be submitted, but the returned job exceeds the maximum supported size, which is 608 KB (kilobytes) of data.

The job is not submitted by HCL Workload Automation for Z as intended. The operation remains in Ready status.

Correct all errors and restart HCL Workload Automation for Z.

If necessary, submit the job manually.

Check that the joblib I/O exit has been correctly installed and that it works correctly.

EQQJ583E

JOB MEMBER IN APPLICATION APPL IS TOO LARGE TO BE SAVED ON THE JS DATA SET

A job that is about to be submitted to JES is too large to be saved in the JCL repository data set.

The job is submitted, but the JCL repository data set is not updated.

If necessary, allocate a new JCL repository data set with a larger maximum record size. Use the IDCAMS REPRO function to copy the old data set into the new data set. Restart HCL Workload Automation for Z.

Use the IDCAMS LISTCAT function to determine the maximum size of records in the data set defined by the EQQJSDS DD statement.

EQQJ584E

JOB MEMBER IN APPLICATION APPL COULD NOT BE SUBMITTED BECAUSE THE EQQUX001 EXIT RETURNED A SUBMITTING USER ID, USER, WHOSE AUTHORITY COULD NOT BE DETERMINED

The job submit exit was called and returned the name of a TSO user on whose behalf the job submit should be done. An authority error occurred when trying to build a job submit environment for this user.

The current job is not submitted. HCL Workload Automation for Z processes the next read operation.

Correct all errors and, if necessary, restart HCL Workload Automation for Z.

If necessary, submit the job manually.

Check that the job submit exit, EQQUX001, returns only valid TSO user names to the caller.

EQQJ585E

INVALID ARITHMETIC EXPRESSION AT LINE LINE OF SCTN

During JCL variable substitution, incorrect syntax was found in SETVAR directive. The possible causes follow, grouped by parameter type:
  • Common causes:
    • One or more parentheses missing.
    • Incorrect variable name.
  • Arithmetic expression with supplied date or time variables:
    • A valid sign (+ or -) is missing.
    • Both plus and minus signs are present in the expression, but only one sign is allowed.
    • Incorrect number in the expression. The number must be in the range 1 to 999.
    • An incorrect type in the expression.
    • Erroneous non-blank characters within parentheses. Any non-blank within parentheses must be part of the arithmetic expression.
    • More than one type was specified for a date variable.
    • Incompatible multiple types found; only HH, MM, SS are allowed for multiple types.
    • The type is incompatible with the variable format.
  • SUBSTR usage:
    • Incorrect number in the expression. The number must be in the range 1 to 60.
    • One or both of the two numeric values that must be specified as SUBSTR parameters (position, length) missing or not valid.
    • Incorrect SUBSTR function syntax.
    • The length of the whole statement reaches column 72.
  • Numeric value usage:
    • Incorrect number. It must be in the range 0 to 99999.
  • Arithmetic with temporary variables:
    • Incorrect operand. It must be in the range 0 to 99999.
    • Incorrect result. It must be in the range 0 to 99999.
    • A valid sign (+ or -) is missing.
    • Both plus and minus signs are present in the expression, but only one sign is allowed.
    • The expression contains blank characters.
  • Alphanumeric value usage:
    • Incorrect syntax. Enclose the string in single quotes.
    • Incorrect syntax. The string cannot exceed 48 characters.
  • Concatenation usage:
    • Incorrect result. It cannot exceed 48 characters.

If the error occurs during job submit, the current operation status is set to ended-in-error with error code OJCV. Otherwise, the status is not changed.

Correct the expression.

EQQJ586W

TEMPORARY VARIABLE VAR IN SETVAR DIRECTIVE NOT REFERRED IN JCL. JOBNAME: JOBNAME

During variable substitution of a job, a SETVAR directive was found and created a temporary variable. The temporary variable was not referred to anywhere in the JCL.

This is a warning. Operation status is not changed.

Either delete the SETVAR directive or make sure that you have a corresponding reference to the temporary variable in your JCL.

EQQJ587W

VARIABLE VAR IN SAVEVAR DIRECTIVE NOT REFERRED IN JCL JOBNAME IS: JNM

During variable substitution of a job, a SAVEVAR directive was found requesting update of the default value of a variable. This variable was not referred to anywhere in the JCL.

This is a warning. Processing continues.

Either delete the variable name from the SAVEVAR directive or make sure that you have a corresponding reference to the variable in the JCL.

EQQJ588E

JOB MEMBER IN APPLICATION APPL IS TOO LARGE TO BE SUBMITTED

This job exceeds 65 535 records, which is the limit that HCL Workload Automation for Z can process.

The job is not submitted. The operation remains in Arriving or Ready status, with extended status Error during job submission.

Submit the job outside of HCL Workload Automation for Z.

EQQJ589E

ETT VARIABLE VAR CANNOT BE USED IN A JCL NOT ADDED VIA ETT. JOBNAME: JOBNM, APPLICATION: APPL

The job is using an ETT occurrence-related variable, but the job was not added through the Event-Triggering Tracking (ETT) mechanism.

The job is not submitted. The current operation is set to ended-in-error with error code OCJV.

Correct the JCL for the operation by removing the ETT variables.

EQQJ590E

VARIABLE TABLE NAME CONTAINS AN INVALID CHARACTER

See text.

None.

Enter a correct value.

EQQJ591E

THE VARIABLE NAME CONTAINS AN INVALID CHARACTER

See text.

None.

Enter a correct value.

EQQJ592E

INVALID VALUE. MUST BE Y OR N

You can enter only Y (for Yes) or N (for No) in this field.

None.

Enter a correct value.

EQQJ594E

THE DEFAULT POSITION MUST BE IN THE RANGE 1-80

The position that you have entered is out of the 80-column range for instream data or a JCL line.

None.

Enter a correct value.

EQQJ595E

VALUE LENGTH IS REQUIRED WHEN COMP.OP IS SPECIFIED

Because you entered a comparison operator, you must enter a value length.

None.

Enter a correct value.

EQQJ596E

COMPARISON OPERATOR REQUIRED WHEN LENGTH IS SPECIFIED

Because you entered a value length, you must enter a comparison operator.

None.

Specify a correct value.

EQQJ597E

THE DEFAULT VALUE VALUE OF THE VARIABLE VAR IS INVALIDATED BY THE VERIFICATION CRITERIA

The default value that was specified for the variable VAR does not comply with the verification rules for the variable.

None.

Enter a correct value.

EQQJ598E

VALIDATION PATTERN IS REQUIRED FOR PICT VERIFICATION

Because you asked for PICT verification, you must enter a validation pattern.

None.

Enter a correct value.

EQQJ599E

NUMERIC MUST BE SPECIFIED FOR RANGE/LIST VERIFICATION

Because you asked for RANGE or LIST verification, you must set the Numeric field to Yes.

None.

Enter a correct value.

EQQJ604I

A DEPENDENCY HAS BEEN MODIFIED

The dependency that you modified has been inserted into the database.

None.

None.

EQQJ606I

A DEPENDENCY HAS BEEN CREATED

The dependency that you created has been inserted into the database.

None.

None.

EQQJ607I

A DEPENDENCY HAS BEEN DELETED

The dependency that you deleted has been removed from the database.

None.

None.

EQQJ609E

YOU ARE NOT AUTHORIZED TO DELETE THIS JCL VARIABLE TABLE

You have tried to delete a JCL variable table that you are not authorized to delete.

None.

If the user should have this authorization, update the RACF profiles.

Contact your system programmer

EQQJ610E

THE JCL IMBED EXIT USRX RETURNED RETCODE = RC WHILE PROCESSING JOB MEMBER IN APPLICATION APPL. THIS RETURN CODE IS NOT SUPPORTED, RETCODE = 4 IS ASSUMED

A JCL imbed exit that was referenced in a FETCH directive of the current JCL returned an invalid return code.

The current operation status is set to ended-in-error with error code OJCV.

Check the exit and correct possible errors. It you change the exit and want to reuse it, restart HCL Workload Automation for Z.

EQQJ611E

INSUFFICIENT STORAGE TO PROCESS JOB MEMBER IN APPLICATION APPL FOR THE JCL IMBED EXIT USRX

HCL Workload Automation for Z was trying to build a JCL record from the data supplied by the exit defined in a FETCH directive, but it could not do so because of insufficient virtual storage.

The current operation status is set to ended-in-error with error code OJCV.

Stop HCL Workload Automation for Z and restart it in a larger region.

EQQJ612E

THE JCL IMBED EXIT USRX COULD NOT FIND JOB MEMBER IN ANY INPUT DATA SET

The exit gave a return code indicating that the JCL could not be found in the exit's input data sets.

The current operation status is set to ended-in-error with error code OJCV.

Correct all errors and restart HCL Workload Automation for Z.

Check that all DD statements needed by the exit have been correctly defined.

EQQJ613E

THE JCL IMBED EXIT USRX DID NOT RETURN ANY DATA FOR JOB MEMBER IN APPLICATION APPL

The exit was called to return JCL to HCL Workload Automation for Z, but no data was returned.

The current operation status is set to ended-in-error with error code OJCV.

Correct all errors and restart HCL Workload Automation for Z.

Check that the exit works correctly and is correctly installed.

EQQJ614E

THE AMOUNT OF DATA RETURNED BY THE JCL IMBED EXIT USRX FOR JOB MEMBER IN APPLICATION APPL EXCEEDS THE MAXIMUM AMOUNT SUPPORTED

The exit was called to return JCL to HCL Workload Automation for Z, but more than 256KB (kilobytes) of data was returned.

The current operation status is set to ended-in-error with error code OJCV.

Correct all errors and restart HCL Workload Automation for Z.

Check that the exit works correctly and is correctly installed.

EQQJ615E

THE JCL IMBED EXIT USRX COULD NOT BE LOADED. THE EXIT WILL BE FLAGGED AS NOT USABLE

HCL Workload Automation for Z was unable to load the exit. HCL Workload Automation for Z does not try to call it again. The exit is flagged as not executable.

The current operation status is set to ended-in-error with error code OJCV.

Correct all errors and restart HCL Workload Automation for Z.

Check the JCL FETCH directive referring to the exit and make sure that the exit is in the current load libraries of the started task JCL for HCL Workload Automation for Z.

EQQJ616E

THE JCL IMBED EXIT USRX HAS ABENDED WHILE PROCESSING JOB MEMBER IN APPLICATION APPL. SEE THE SYSUDUMP DATA SET FOR MORE INFORMATION. THE EXIT WILL BE FLAGGED AS NOT USABLE

The exit abended while processing. HCL Workload Automation for Z does not try to call it again. The exit is flagged as not executable.

The current operation status is set to ended-in-error with error code OJCV.

Identify the cause of the error in the exit analysis SYSDUMP data set. Correct all the errors in the exit and restart HCL Workload Automation for Z.

EQQJ617E

JOB MEMBER IN APPLICATION APPL REFERS TO AN UNUSABLE JCL IMBED EXIT, USRX. NO DATA CAN BE RETRIEVED USING THIS EXIT

HCL Workload Automation for Z has previously discovered an abend in this exit and marked it as not executable. This exit is not called again.

The current operation status is set to ended-in-error with error code OJCV.

Correct the exit and restart HCL Workload Automation for Z to reuse the exit.

EQQJ618E

INSUFFICIENT STORAGE FOR RECORD READ FROM JS DATA SET. APPLICATION IS: APPL, JOBNAME IS MEMBER

HCL Workload Automation for Z tried to allocate storage for a record read from the JS data set, but the request for storage failed.

The operation status depends on the SUBFAILACTION keyword in the JTOPTS initialization statement. The operation can:
  • Keep status R or extended status RE
  • Get status C (complete)
  • Get status E (ended-in-error) with error code OSUF.

Make sure that HCL Workload Automation for Z is running in a large enough region and restart HCL Workload Automation for Z.

EQQJ702I

THE JCL VARIABLE TABLE HAS BEEN DELETED

The JCL variable table has been removed from the HCL Workload Automation for Z database.

The variable table is deleted.

None.

EQQJ703E

THE JCL VARIABLE TABLE IS BEING UPDATED BY ANOTHER USER

You cannot access the variable table because it is being updated by another user.

The system waits for you to respond.

Try again later.

EQQJ704E

THE JCL VARIABLE TABLE TID ALREADY EXISTS

You have tried to create a table that already exists.

The system waits for you to respond.

Enter the correct data and try again.

EQQJ705I

THE JCL VARIABLE TABLE HAS BEEN REPLACED IN THE DATA BASE

The JCL variable table has been modified and successfully updated in the database.

The system waits for you to respond.

None.

EQQJ706E

JCL VARIABLE TABLE ENTRY COULD NOT BE RETRIEVED

You have tried to access a JCL variable table that has been deleted since the variable table list was displayed.

The system waits for you to respond.

Check if another user has already deleted the table.

EQQJ707I

A JCL VARIABLE DEFINITION HAS BEEN CREATED

A JCL variable definition has been created and inserted in the database.

None.

None.

EQQJ708I

THE JCL VARIABLE TABLE HAS BEEN REPLACED IN THE DATA BASE

The JCL variable table has been modified and successfully replaced in the database.

None.

None.

EQQJ712E

THE VARIABLE TO BE DELETED HAS DEPENDENCIES

Another variable is dependent on this variable.

None.

To delete this variable, first remove the dependency. You can reassign the dependency, delete the dependency, or delete the dependent variable.

EQQJ713E

THE NUMBER OF VALUES MUST BE EVEN FOR RANGE TYPE

You specified an odd number of values for a range verification.

The system waits for you to respond.

Correct the error and try again.

EQQJ714E

THE LIST OF VALUES CONTAINS A BAD VALUE PAIR

One of the pairs of values that you specified is in error.

The system waits for you to respond.

Correct the error and try again.

EQQJ715E

THE CHARACTER CHR IN POSITION POS IS INVALID

The value that you entered contains a character that is not numeric.

The system waits for you to respond.

Correct the error and try again.

EQQJ716E

ONE VALID VALUE CANNOT EXCEED 44 POSITIONS

You defined as valid a value that contains more than 44 characters. This is not allowed.

The system waits for you to respond.

Correct the error and try again.

EQQJ717E

THE DEPENDENT VARIABLE VALUE IS INVALID FOR THE VERIFICATION TYPE

The dependent value that you entered does not comply with the verification rules for the dependent variable.

The system waits for you to respond.

Enter the correct value.

EQQJ800E

INVALID VALUE. MUST BE Y, N OR P

In this field, you can enter only Y (for Yes), N (for No), or P (for Prompt).

None.

Enter a correct value.

EQQJ801E

VALUES/RANGE MUST BE SPECIFIED FOR RANGE/LIST

You specified verification type RANGE or LIST, but did not specify any values.

The system waits for you to respond.

Correct the error and try again.

EQQJ802E

NUMERIC CAN ONLY BE SPECIFIED FOR RANGE/LIST VERIFICATION

You specified a valid numeric field type, but did not specify RANGE or LIST verification.

The system waits for you to respond.

Correct the error and try again.

EQQJ805E

INVALID VERIFICATION TYPE

Valid types are ALPHA, NUM, ENUM, HEX, BIT, PICT, NAME, DSNAME, RANGE and LIST.

None.

Enter a correct value.

EQQJ806E

INVALID VALUE LENGTH

The length must be in the range 1 to 44.

None.

Enter a correct value.

EQQJ807E

INVALID COMPARISON OPERATOR

Valid operators are:

  EQ LT GT LE GE NE NG NL
  = < > <= >= ¬= ¬> ¬<

None.

Enter a correct value.

EQQJ808I

THERE ARE NO DEPENDENCIES DEFINED FOR THIS VARIABLE

There are no dependencies defined for this variable.

None.

None.

EQQJ809E

THE INDEPENDENT VALUE DOES ALREADY EXIST

You specified a duplicate value for the independent variable.

The system waits for you to respond.

Correct the error and try again.

EQQJ810I

THERE ARE NO VERIFICATION CRITERIA DEFINED FOR THIS VARIABLE

There are no verification criteria defined for this variable.

None.

None.

EQQJ811E

THE VARIABLE ALREADY EXISTS IN THE CURRENT VARIABLE TABLE

You have defined a variable that already exists in this table.

EQQJ812E

VARIABLE NAME CONTAINS AN INVALID CHARACTER

See text.

None.

Enter a correct value.

EQQJ813E

TABLE NAME CONTAINS AN INVALID CHARACTER

See text.

None.

Enter a correct value.

EQQJ814E

OWNER ID IS MISSING

See text.

None.

Enter the owner ID.

EQQJ815E

SUBSTITUTION EXIT NAME CONTAINS AN INVALID CHARACTER

See text.

None.

Enter a correct value.

EQQJ816E

THE MAXIMUM NUMBER OF DEPENDENCIES IS 360

You tried to define more than 360 dependencies.

The system waits for you to respond.

Type over the incorrect value and press Enter.

EQQJ817E

THE INDEPENDENT VARIABLE NAME IS REQUIRED

You tried to enter a value for an independent variable without specifying an independent variable name.

The system waits for you to respond.

Correct the error and try again.

EQQJ818E

THE VERIFICATION LENGTH DIFFERS FROM THE LENGTH OF VALID VALUES

You have specified a verification length that is shorter than one of the values listed in the valid VALUES or RANGES.

The panel is redisplayed with the cursor pointing at the field that is in error.

Correct the length or values, and try again.

EQQJ819E

VALUE OF DEPENDENT IS TOO LONG

The value in the value-of-dependent field is longer than the value length specified on the Specifying Verification Criteria panel.

The panel is redisplayed with the cursor pointing at the field that is in error.

Either change the value-of-dependent field or the value length of the dependent variable.

EQQJ820E

THE SUBSTRING START OR LENGTH IS INCORRECTLY SPECIFIED.

You entered incorrect or inconsistent values in the SUBSTRING fields of the JCL Variable Dependency Value List panel. The message is issued in the following cases:
  • The fields are not in the range 0-44.
  • You specified only one field.
  • You entered non numeric values.

The panel is redisplayed with the cursor pointing at the field that is in error.

Correct the values and try again.