EQQD000 - EQQD159
EQQD000E
YOU DO NOT HAVE AUTHORITY TO ACCESS THE CURRENT PLAN DATA SET
None.
EQQD001E
INVALID VALUE SPECIFIED FOR REPORT SELECTION
If you want a report, you must specify a Y. If you do not want a report, you must specify an N.
None.
Specify a correct value and press Enter.
EQQD002E
START AND END DATES MUST NOT BE THE SAME
See text.
None.
Specify a correct value and press Enter.
EQQD003I
ENTER END AGAIN TO EXIT, OR PRESS ENTER TO PRINT
You can either cancel the print request and leave this panel by entering END again or print the specified reports by pressing ENTER.
The system waits for you to respond.
Enter END or press ENTER.
EQQD004E
END TIME MUST BE LATER THAN START TIME
See text.
None.
Specify a correct value and press Enter.
EQQD005E
END DATE MUST BE LATER THAN START DATE
See text.
None.
Specify a correct value and press Enter.
EQQD006E
THE END TIME MUST BE A VALUE 00.01 TO 24.00
See text.
None.
Specify a correct value and press Enter.
EQQD007E
SPECIFY A (ALL DAYS) OR W (WORKDAYS ONLY)
See text.
None.
Specify a correct value and press Enter.
EQQD008E
THE EXTENSION TIME SPECIFIED MAY NOT BE > 21 DAYS OR 504 HOURS
The extension time that you specified is greater than 21 days (504 hours), the maximum allowed extension time.
The system waits for you to respond.
Enter a valid extension time.
EQQD009E
A MINUTE VALUE GREATER THAN 59 IS NOT ALLOWED
See text.
None.
Specify a correct value and press Enter.
EQQD010E
EXTENSION TIME MUST BE IN THE FORM HHHMM
The valid extension time format is HHHMM, where HHH is 000 through 504 and MM is 00 through 59.
None.
Specify a correct value and press Enter.
EQQD011E
SPECIFY EITHER EXTENSION OR END DATE AND TIME
To extend a plan period, you must specify either an extension length or an end date and time, but not both.
None.
Specify a correct value and press Enter.
EQQD012E
END DATE OR EXTENSION LENGTH MUST BE FILLED IN
To extend a plan period, you must specify either an end date and time or an extension length.
None.
Specify a correct value and press Enter.
EQQD013E
A START DATE MUST BE SPECIFIED
You must specify a start date because no current plan exists.
None.
Specify a correct value and press Enter.
EQQD014E
A CURRENT PLAN ALREADY EXISTS FOR THE SPECIFIED PERIOD
You specified a start date and time for a current plan when a current plan already exists.
The system waits for you to respond.
Blank out the start date and time and enter a valid extension length.
EQQD015E
NO CURRENT PLAN EXISTS, SPECIFY START DATE AND TIME
To create a current plan, you must specify a start date and time.
None.
Specify a correct value and press Enter.
EQQD016E
NO CURRENT PLAN EXISTS, FUNCTION CANNOT BE USED
You have attempted to use a function that requires the existence of a current plan.
The system waits for you to respond.
Check why a current plan does not exist.
EQQD017E
SPECIFIED PERIOD MUST BE WITHIN CURRENT PLAN PERIOD
The start and end times must be within the current plan start and end times.
None.
Specify a correct value and press Enter.
EQQD018E
PLAN START MUST BE EQUAL TO OR GREATER THAN CURRENT PLAN END
The start of the future trial plan cannot be before the end of the current plan.
The system waits for you to respond.
Enter a valid start date and time.
EQQD019E
INVALID VALUE SPECIFIED FOR COPY VSAM USAGE SELECTION
See text.
None.
To copy VSAM usage data, specify Y. Otherwise, specify N.
EQQD020E
END DATE AND TIME MUST BE LATER THAN CURRENT PLAN END
When extending the current plan, the end date and time must be later than the end of the current plan.
The system waits for you to respond.
Enter an end date and time that is later than the current plan end.
EQQD142I
DB2TXT
This message describes why HCL Workload Automation for Z could not access the DB2 history database. It contains messages issued by the DB2 system.
Processing continues.
Review the messages issued by DB2 and take the action described in the DB2 documentation.
Contact your system programmer.
EQQD143I
DB2 SYSTEM DB2 HAS STOPPED. THE HISTORY FUNCTION IS NOT AVAILABLE
The scheduler has discovered that the DB2 system has either stopped or abended. It cannot support requests for data from the history database.
Processing continues but the history function is not available.
Restart the DB2 system that stopped or abended.
Contact your system programmer.
EQQD144I
DB2 SYSTEM DB2 IS AVAILABLE
The DB2 system containing the scheduler history data is available.
Processing continues.
None.
None.
EQQD146I
OBJECT OBJ HAS BEEN CREATED IN THE HISTORY DATABASE
The initialization program has successfully created this object in the history database.
Processing continues.
None.
EQQD148E
AN IDENTIFY REQUEST FOR CONNECTION TO DB2 WAS REJECTED. DB2 HAS BEEN STARTED IN RESTRICTED ACCESS MODE.
HCL Workload Automation for Z loses the connection to DB2 because DB2 was started in restricted access mode, using ACCESS(MAINT).
Processing continues
Stop DB2 and restart it without the
ACCESS keyword. To connect HCL Workload Automation for Z to DB2,
as soon as DB2 is up again, enter the following operator command: /F
subsystemname, DB2RETRY
Contact your system programmer.
EQQD149E
THE CAF INTERFACE FAILED WITH RC
This message explains why HCL Workload Automation for Z cannot connect with DB2. It includes the error code issued by the DB2 system.
Processing continues.
Review the return code issued by DB2 and follow the actions described in the DB2 documentation.
Contact your system programmer.
EQQD150I
A HIST COMMAND WAS ISSUED ON DATE AT TIME BY USER USER OF SUBSYSTEM SUBSYS
The user entered a HIST command to retrieve data from the HCL Workload Automation for Z history database, from the subsystem indicated. Retrieving data was started on date and time, as indicated.
Processing continues.
Wait for the operation result. For the command execution status, refer to messages EQQD151I, EQQD152I, and EQQD153I.
EQQD151I
DATA RETRIEVAL FROM THE HISTORY DATABASE HAS STARTED
Based on a HIST command issued, the data retrieval has started. To identify the HIST command that was entered, refer to message EQQD150I.
Processing continues.
Wait for the operation result. For the command execution status, refer to messages EQQD152I, and EQQD153I.
EQQD152I
DATA RETRIEVAL FROM THE HISTORY DATABASE HAS COMPLETED
Based on a HIST command issued, the data retrieval has completed. To identify the HIST command that was entered, refer to message EQQD150I.
Processing continues. Data is forwarded to the requesting panel user.
Wait for data to be displayed in the panel.
EQQD153I
REQUIRED DATA NOT RETRIEVED FROM THE HISTORY DATABASE. REASON: THE LIMIT SET BY MAXHISTORYROWS WAS REACHED.
You issued a HIST command to retrieve data from the HCL Workload Automation for Z history database. The number of rows retrieved from the database exceeds the maximum allowed by the MAXHISTORYROWS keyword.
The request is cancelled. No data is returned from the history database.
Set some filtering criteria to reduce the amount of data retrieved from the history database or ask the system administrator to increase the value set in the MAXHISTORYROWS keyword.
If needed, increase the value set in the MAXHISTORYROWS keyword.
EQQD159I
RETRIEVED JOBLOG (JOBN JNUM) for APPLICATION APPL IA OPERATION OPER WAS NOT STORED BECAUSE A NEW JOB RUN OCCURRED.
A new job run occurred before a joblog retrieval request for a previous run was able to complete. The requested joblog is now obsolete. The joblog (identified by jobname JOBN, JobId JNUM, Application Name APPL, input arrival time IA and operation numberOPER ) will not be stored in JS VSAM.
The joblog is not stored in JS VSAM.
None.