EQQCN00 - EQQCN99
EQQCN00I
START CLEANUP AND, OR RET-CODE SIMULATION PROCESS(ES)
EQQCLEAN stand-alone data set cleanup and return code simulation process has been started
Cleanup and return code simulation process continues.
None.
EQQCN01E
NO MATCH FOUND FOR SYSIN RECORD: STRING
The EQQCLEAN stand-alone data set cleanup and return code simulation process detected a mismatch between the JCL executed and the step list specified in EQQSIMDD DD. STRING identifies the step number, return code, step name, and procedure name.
Cleanup and return code simulation process ends in error.
Save the JCL and the message log, then contact the Software Support.
The content of the EQQSIMRC DD or some JCL lines might have been modified manually after the restart and cleanup process analyzed and created the submitted JCL. If nobody modified the JCL, contact your System Programmer.
EQQCN02I
PROGR STEPNAME PROCNAME RC
EQQCLEAN stand-alone data set cleanup and return code simulation process simulated RC return code for stepname STEPNAME procstepname PROCNAME step number PROGR.
Cleanup and return code simulation process continues.
None.
EQQCN03I
PROGR STEPNAME PROCNAME ABEND
EQQCLEAN stand-alone data set cleanup and return code simulation process simulated ABEND ABEND code for stepname STEPNAME procstepname PROCNAME step number PROGR.
Cleanup and return code simulation process continues.
None.
EQQCN04I
PROGR STEPNAME PROCNAME USERCODE
EQQCLEAN stand-alone data set cleanup and return code simulation process simulated USERCODE user code for stepname STEPNAME procstepname PROCNAME step number PROGR.
Cleanup and return code simulation process continues.
None.
EQQCN05I
PROGR STEPNAME PROCNAME FLUSH
EQQCLEAN stand-alone data set cleanup and return code simulation process simulated a FLUSH for stepname STEPNAME procstepname PROCNAME step number PROGR.
Cleanup and return code simulation process continues.
None.
EQQCN06E
INVALID PARAMETER IN SYSIN, PROCESS TERMINATED
EQQCLEAN stand-alone data set cleanup and return code simulation process received an invalid parameter.
Cleanup and return code simulation process ends in error.
Save the JCL and the message log, then contact the Software Support.
The content of the EQQCLEAN step might have been modified manually after the restart and cleanup process analyzed and created the submitted JCL. If nobody modified the JCL, contact your System Programmer
EQQCN10I
DLTD DEVTYPE VIA RMM DSNAME
The EQQCLEAN stand-alone data set cleanup and return code simulation process deletes data set DSNAME stored on device type DEVTYPE using HSM services.
Cleanup and return code simulation process continues
None.
EQQCN11I
TSO/E MESSAGE: MSGCODE IN ACTION PROCESS
The EQQCLEAN stand-alone data set cleanup and return code simulation process kept a return code RC performing ACTION using IDCAMS services
Cleanup and return code simulation process ends in error.
Contact your system programmer.
Review the JCL message log data set to determine the cause of the problem.
EQQCN12I
ACTION DEVTYPE DSNAME
The EQQCLEAN stand-alone data set cleanup and return code simulation process did the ACTION action on data set DSNAME stored in a DEVTYPE device type.
Cleanup and return code simulation process continues.
None.
EQQCN13I
DLTD DEVTYPE VIA RMM DSNAME
The EQQCLEAN stand-alone data set cleanup and return code simulation process deletes data set DSNAME stored on device type DEVTYPE using RMM services.
Cleanup and return code simulation process continues.
None.
EQQCN14E
ERROR IN DATA SET CLEANUP: JOB STOPPED
The EQQCLEAN stand-alone data set cleanup and return code simulation process was not able to perform one or more cleanup actions.
Cleanup and return code simulation process ends in error.
If the problem persists, for the information to collect, see the Diagnosis Guide and Reference, "Problem analysis procedures" section.
Review the JCL message log data set to determine the cause of the problem.
EQQCN15W
RMM MACRO CMD CMDTYPE: RMM_COMMAND RMM MACRO RC: RC RSC: RSC
- BEGIN
- CONTINUE
- RELEASE
The RMM macro return code and reason code are indicated by the "RC" and "RSC" values. See "Using the DFSMSRMM Application Programming Interface - Chapter 1 - EDGXCI Return and Reason Codes" and "DFSMSRMM Guide and Reference - Chapter 11 - DFSMSRMM Return Codes and Reason Codes" for details.
EQQCLEAN or EQQDELDS is stopped and ends in error.
Contact your system programmer.
EQQCN16I
ALREADY DELETED DSNAME
The EQQCLEAN stand-alone data set cleanup and return code simulation process tried to delete the DSNAME data set but it does not exist. The data set was probably deleted manually.
Cleanup and return code simulation process continues.
EQQCN17I
VOLSER
The EQQCLEAN process sends this message that follows EQQCN12I. It contains the volser name involved in the cleanup operation.
Cleanup and return code simulation process continues.
None.
EQQCN18I
SNUM STEPNAME PROCNAME RC
This message is followed by EQQCN02I messages and is a header message used as a layout.
SNUM indicates the step number.
STEPNAME is the step name
PROCNAME is the procedure step name
RC is the return code.
None.
None.
EQQCN19E
INVALID SYSIN INPUT: SYSINREC
EQQCLEAN program (used for cleanup and/or return code simulation) has invalid sysin input data: SYSINREC.
Cleanup and return code simulation process ends in error and job fails.
Save the JCLl and message log, and contact the Software Support.
The content of EQQSIMDD, EQQGDGDD, or EQQROOTD, DD was incorrectly built by the scheduler. Contact your system administrator.
EQQCN20I
EQQUXCAT EXIT IGNORED DATA SET: dsname
The EQQCLEAN program invoked the user exit EQQUXCAT before executing the cleanup action for the data set specified by dsname. EQQUXCAT checked the data set and decided that no action should be done.
No cleanup action is taken for the specified data set.
None.
EQQCN21I
CLEAN UP DETAILS FOLLOW: details
EQQCLEAN program was used by scheduler to execute clean up and /or restart action. The variable details will contain all the IDCAMS messages related to this action. This message can also be issued by the EQQDELDS sample program if RMM is involved.
If an error is detected clean up action fails otherwise the process continues.
Check the IDCAMS messages to understand if there was a problem.
None.
EQQCN22I
START GDG NAME SIMULATION PROCESS
The EQQCLEAN pre-step is going to simulate GDG names in order to enable Step Restart. (This process consists in overwriting the GDGs in the submitted JCL appropriately, in order to correctly execute a Step Restart).
None.
None.
EQQCN23I
GDG NAME SIMULATION PROCESS ENDED
The EQQCLEAN pre-step has finished simulating GDG names in order to enable Step Restart (this process consists in overwriting the GDGs in the submitted JCL appropriately, in order to correctly execute a Step Restart).
None.
None.
EQQCN24I
NOT SIMULATED GDG DATA SETS: SNUM GDGDSNAME GDGRELNUM
EQQCN24I is shown as follows:
EQQCN24I – NOT SIMULATED GDG DATA SETS:
EQQCN26I – SNUM DSNAME RELNUM
EQQCN24I – snum gdgdsnam gdgrelnum
EQQCN24I – snum gdgdsnam gdgrelnum
.....
The GDG data sets identified by SNUM GDGDSNAME GDGRELNUM have not been simulated; in fact, they were found within non–simulated steps, but the corresponding GDG information was not available. This is usually not a problem. In fact, information about GDG data sets belonging to previously unexecuted steps is normally not provided when you run a step restart: however, EQQCLEAN acknowledges that these data sets are in the JCL and issues message EQQCN24I to inform you about this.
Processing continues.
None.
EQQCN25I
SNUM GDGDSNAME GDGRELNUM
The GDG data set identified by SNUM GDGDSNAME GDGRELNUM has been successfully simulated.
Processing continues.
None.
EQQCN26I
SNUM DSNAME RELNUM
This message is followed by a list of EQQCN24I, EQQCN25I, or EQQCN28I messages. It provides a header for these messages, where:
SNUM: is the step number
DSNAME: is the GDG simulated data set name
RELNUM: is the relative GDG number
Processing continues.
None.
EQQCN27W
STEPNAME PROCNAME STEPNUM MISMATCH: SYSINSNUM/ SNUM
EQQCLEAN tried to simulate the step identified by STEPNAME, PROCNAMEand SYSINSNUM, but no exact match was found in the JES SCT control blocks. A match was found for STEPNAME PROCNAME, but the step number in SCT was SNUM
EQQCLEAN simulates the step in the SCT found with the partial match, without considering the step number.
None.
EQQCN28I
EQQUXGDG EXIT EXCLUDED FROM SIMULATION FOLLOWING GDG: SNUM GDGDSNAME GDGRELNUM
EQQCN28I is displayed as follows:
EQQCN28I – EQQUXGDG EXIT EXCLUDED FROM SIMULATION FOLLOWING GDG:
EQQCN26I – SNUM DSNAME RELNUM
EQQCN28I – snum gdgdsnam gdgrelnum
EQQCN28I – snum gdgdsnam gdgrelnum
.....
The EQQUXGDG exit, called before executing the simulation, asked to exclude this GDG from simulation.
EQQCLEAN does not simulate the indicated GDG.
None.
EQQCN29E
ERROR IN RMM PROCESS. RC: RC REASON: RSC DSN: DSNAME
- RC=2 Error in IDCAMS command
- RC=3 Data Set not found
For details about RMM failure, the HCL Workload Automation for Z internal RMM trace can be seen in the SYSPRINT data set.
If the failure occurred in the RMM API, the macro message EQQCN15W will display more details about this.
EQQCLEAN or EQQDELDS process is stopped and ends in error.
If the problem persists, for the information to collect, see the Diagnosis Guide and Reference, "Problem analysis procedures" section.
EQQCN90E
UNABLE TO LOAD BEX: EQQCLEAN PROGRAM NOT EXECUTED.
The EQQCLEAN program could not load a BEX enviroment.
Processing ends in error and job fails.
Check that the data set referred to by the STEPLIB in the EQQCLEAN sample procedure contains the whole HCL Workload Automation load library.
EQQCN99I
CEANUP AND, OR RET-CODE SIMULATION PROCESS(ES) ENDED
The EQQCLEAN stand-alone data set cleanup and return code simulation process ends.
None.