EEWI01 - EEWI42
EEWI01E
yymmdd hhmmss module FAILED, MACRO macro NEAR LABEL label WITH RETURN CODE = reason code & REASON CODE = reason code
The specified module failed because an error occurred in the specified macro. One possible cause might be a TCP/IP connection problem.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- macro
- The name of the macro after that the error message was issued.
- label
- The name of the label in the source code nearest to the instruction that failed.
- return code
- The return code value.
- reason code
- The reason code value.
The system proceeds.
Verify the return code and the reason code specified in the message to understand the error. If the problem persists contact IBM Software Support for assistance.
EEWI02E
yymmdd hhmmss module FAILED, MACRO macro NEAR LABEL label WITH RETURN CODE = return code & ERROR NUMBER = error number
The specified module failed because an error occurred in the specified macro. One of the possible causes can be TCP/IP connection problem.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- macro
- The name of the macro after which the error message is issued.
- label
- The name of the label in the source code nearest to the instruction that failed.
- return code
- The return code value.
- error number
- The error number.
The system proceeds.
Verify the return code and the error number specified in the message to understand the error. If the problem persists contact IBM Software Support for assistance.
EEWI08S
yymmdd hhmmss module FAILED, AT OFFSET offset
See text. This message is issued by the ESTAE routine.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- offset
- The offset value.
The system stops.
Set SVCDUMP to YES collect the dump and send it to IBM Software Support for assistance.
EEWI10S
yymmdd hhmmss module ABENDED WITH ASSOCIATED REASON CODE reason code
The specified module ended abnormally with the specified reason code.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- reason code
- The reason code value.
The system stops.
Restart the start task that contains the module. If the problem persists contact IBM Software Support for assistance.
EEWI15E
yymmdd hhmmss module DATASET "dataset" DDNAME "dd" FAILED TO OPEN NEAR LABEL label
The specified data set is not available.
The system proceeds.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- data set
- The name of the data set that failed to open.
- dd
- The internal dd.
- label
- The name of the label in the source code nearest to the instruction that failed.
- The data set was not deleted.
- The data set is not in use.
- You are authorized to use the specified data set.
EEWI18E
yymmdd hhmmss module INVALID TERMINATOR term
You specified an invalid value for the TERMINATOR parameter.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- term
- The value you assigned to the TERMINATOR parameter.
The system stops.
Specify a valid value for the TERMINATOR parameter and restart the start task. The default value is x'25'.
EEWI19E
yymmdd hhmmss module near label label invalid value found name = value
You specified an invalid value for the TERMINATOR parameter.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- label
- The name of the label in the source code nearest to the instruction that failed.
- name
- The name of the variable that has an invalid value.
- value
- The actual value of the variable.
The system stops.
Specify a valid value for the TERMINATOR parameter and restart the module. The default value is x'25'.
EEWI20E
yymmdd hhmmss module NEAR LABEL label FAILED TO FIND ACTIVE SMF IEFU84 EXIT
The IEFU84 exit is not active.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- label
- The name of the label in the source code nearest to the instruction that failed.
The system stops.
Activate the IEFU84 exit.
EEWI24E
yymmdd hhmmss module NEAR LABEL label error description
The IEFU84 exit is not active.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
- label
- The name of the label in the source code nearest to the instruction that failed.
- error description
- The description of the error. Possible values are:
- Unkwown status in occurrence record
- HCL Workload Automation current plan status in not active
The system stops.
If the problem persists, contact IBM Software Support for assistance.
EEWI27I
APPLICATION application WAS INSERTED IN CURRENT PLAN WITH INPUT ARRIVAL DATE AND TIME yymmdd hhmmss
There is no further help information available.
EEWI28W
yymmdd hhmmss APPLICATION application WAS NOT INSERTED IN CURRENT PLAN WITH INPUT ARRIVAL DATE AND TIME iadatetime
The specified application was not submitted in the current plan.
- yymmdd hhmmss
- The date and time the error occurred.
- application
- The name of the application that was not submitted in the current plan.
- iadatetime
- The input arrival date and time.
The system proceeds.
- The date and time on which you submitted the application is outside the validity interval specified when the application was defined.
- The input arrival date and time specified during the submission is outside the current plan validity interval.
- You did not already submit this application with the same input arrival date and time.
EEWI32S
yymmdd hhmmss module AT LEAST ONE INTERFACE MUST BE DIFFERENT FROM NODE
Both the HCL Workload Automation for Z and JES interfaces are set to NO. One must be set to YES, otherwise the access method has no interface with which to communicate.
- yymmdd hhmmss
- The date and time the error occurred.
- module
- The name of the module that issued the message. For a detailed list, see z/OS module names.
The system stops.
Specify a value other than NO for either of the parameters: JESINTERFACE, and OPCINTERFACE. Start the started task again.
EEWI33W
yymmdd hhmmss TASK task APPLICATION application CANNOT BE INSERTED IN THE CURRENT PLAN
The occurrence could not be inserted in the current plan of HCL Workload Automation for Z.
- yymmdd hhmmss
- The date and time the error occurred.
- task
- The name of the task that issued the message.
- application
- The name of the application that was submitted in the current plan.
The system proceeds.
Define the application correctly in the HCL Workload Automation for Z database and restart the request.
EEWI34W
APPLICATION application CANNOT BE INSERTED IN THE CURRENT PLAN
The occurrence could not be inserted in the current plan of HCL Workload Automation for Z.
- The application is not defined in the HCL Workload Automation for Z Application Description database
- The application valid-from date is later than the current plan end date
The system proceeds.
Define the application correctly in the HCL Workload Automation for Z database and restart the request.
EEWI35W
JCL dataset(member) NOT FOUND
The indicated JCL was not found in the JCL library.
- dataset
- The name of the data set that was expected to contain the JCL.
- member
- The name of the member containing the JCL.
The system proceeds.
Define the JCL in the correct member of the data set and restart the request.
EEWI36W
yymmdd hhmmss IA AND IATIME CANNOT BE SPECIFIED TOGETHER
Both the IA and the IATIME parameters were supplied in the task definition.
- yymmdd hhmmss
- The date and time the error occurred.
The system proceeds.
Reissue the request, supplying only one of the indicated parameters.
EEWI37W
yymmdd hhmmss DEADLINE AND DEADLINETIME CANNOT BE SPECIFIED TOGETHER
Both the DEADLINE and the DEADLINETIME parameters were supplied in the task definition.
- yymmdd hhmmss
- The date and time the error occurred.
The system proceeds.
Reissue the request, supplying only one of the indicated parameters.
EEWI38I
jobname (jobid) n1 n2 result restype
See text.
- jobid
- The identifier of the job.
- n1
- The number of seconds passed from the request.
- n2
- The number of seconds of CPU time consumed.
- result
- Can be one of the following values:
- ABEND
- If the job ends abnormally. In this case restype can be:
- Sxyz
- System Abend
- Unnnn
- User Abend
- CONDCOD
- The job does not end successfully due to the condition code of one step that does not match the definition. In this case restype contains: the RC=nnnnn value of the return code of the last step that was run, if LASTSTEP specified, or of the worst step that does not match the definition of the job on the distributed side.
- EXEC
- If the job is running or is in the input queue.
- JCLERRO
- If the job failed due to a JCL error.
- SUCCES
- If the job completed successfully.
- UNKNOWN
- If the job ID is unknown.
- blank
- In case of an internetwork dependency when the manual submission was not performed.
EEWI42I
yymmdd hhmmss TASK task MODULE EEWTCP65 ISSUED, MACRO 'EZASMI TYPE=GETPEERNAME' NEAR LABEL 'M2505710' TO GET PEER ADDRESS = address
See text.
- yymmdd hhmmss
- The date and time the error occurred.
- task
- The name of the task.
- address
- The address of the remote partner.