Workstation_id |
The identifier of the workstation. |
character |
16 |
Domain_id |
The identifier of the domain of the workstation
specified in the Workstation_id column. |
character |
16 |
Host_workstation_id |
The identifier of the workstation that hosts the
workstation specified in the Workstation_id column. |
character |
16 |
Method |
The name of the access method for extended agents
workstations. |
string |
40 |
Workstation_type |
The workstation type status. Possible values are:
- M
- Manager
- F
- FTA
- X
- XA
- S
- SA
- B
- Broker
- A
- Agent
- L
- Pool
- Y
- Dynamic_pool
- E
- Remote_engine
|
character |
1 |
Behind_firewall |
If the workstation in behind the firewall. Possible
values are:
- Y
- Yes
- N
- No
|
character |
1 |
Fence |
The job fence for the workstation specified in
the Workstation_id column. |
integer |
3 |
Agent_initialized |
If the jobman process is initialized. Possible
values are:
- Y
- Yes
- N
- No
|
character |
1 |
Agent_running |
If the jobman process is running. Possible values
are:
- Y
- Yes
- N
- No
|
character |
1 |
Limit |
The total number of jobs that can be run concurrently
on the workstation specified in the Workstation_id column. |
integer |
4 |
Link_status |
The workstation link status. Possible values are:
- L
- Linked
- U
- Unlinked
- F
- Fully_linked
- N
- Not_applicable
|
character |
1 |
Workstation_name |
A hexadecimal identifier used in the Symphony file to identify the
workstation. |
string |
16 |
Workstation_original_name |
The name of the workstation |
string |
16 |
Node_name |
The node name of the workstation. |
string |
51 |
Ssl_communication |
The workstation SSL communication level. Possible
values are:
- O
- On
- N
- None
- E
- Enabled
- F
- Force
- H
- Http
- S
- Https
|
character |
1 |
Mailman_server |
The name of the mailman server responsible for
the Workstation_id on the domain manager. It is for fault-tolerant
and standard agents only. |
character |
1 |
Ssl_port |
The number of the secure port to be used for SSL
communication. |
integer |
5 |
Monitor_config_updated |
If the monitor configuration is updated. Possible
values are:
- Y
- Yes
- N
- No
|
character |
1 |
Start_time |
The date and time when the batchman process
was started on the workstation. |
timestamp |
10 |
Run_number |
The run number of the current plan running on the
workstation. This is used to synchronize the workstations in a HCL Workload Automation network. |
integer |
10 |
Node_port |
The port number of the workstation. |
integer |
5 |
Time_zone |
The time zone set on the workstation. |
string |
40 |
Node_information |
The operating system information of the workstation. |
string |
64 |
Version |
The HCL Workload Automation version
that runs on the workstation. |
string |
8 |
Writer_running |
If the writer is running. Possible values are:
- Y
- Yes
- N
- No
|
character |
1 |
Event_processor |
If the event processor is running. Possible values
are:
- Y
- Yes
- N
- No
|
character |
1 |
Event_monitoring |
If the event monitoring is running. Possible values
are:
- Y
- Yes
- N
- No
|
character |
1 |
Workstation_folder_name |
The name of the folder where the workstation is defined. |
string |
801 |
Workstation_folder_id |
The identifier of the folder where the workstation is defined. |
character |
16 |