LTOP - Operation segment

LTP changed operation.

Note: Y and N are the indicator values.
Table 1. LTOP Control Block
Offsets        
Dec Hex Type Len Name Description

0

(0)

STRUCTURE

64

LTOP

CHANGED OPERATION

0

(0)

CHARACTER

4

LTOPWSN

WORKSTATION NAME

4

(4)

SIGNED

4

LTOPNO

OPERATION NUMBER

8

(8)

CHARACTER

10

LTOPOI

OPERATION INPUT ARRIVAL

8

(8)

CHARACTER

6

LTOPOID

DATE | BLANK

14

(E)

CHARACTER

4

LTOPOIT

TIME | BLANK

18

(12)

CHARACTER

10

LTOPOD

OPERATION DEADLINE
18 (12) CHARACTER 6 LTOPODD DATE | BLANK
24 (18) CHARACTER 4 LTOPODT TIME | BLANK
28 (1C) CHARACTER 24 LTOPDESC OPERATION TEXT
52 (34) UNSIGNED 1 LTOPVERS VERSION NUMBER=1
53 (35) CHARACTER 11

*

RESERVED