All |
- Verify in the EQQMLOG data set that the event writer has started
successfully.
- Verify that the definition of the EQQEVDS ddname
in the HCL Workload Automation for Z started-task
procedure is correct (that is, events are written to the correct data
set).
- Verify that the required exits have been installed.
- Verify that the IEFSSNnn member of SYS1.PARMLIB
has been
updated correctly, and that an IPL of the z/OS system
has been performed
since the update.
|
A1 |
If both A3P and A5 events are also missing:
- Verify that the HCL Workload Automation for Z version of the JES2 exits 7 and 51
routines have been correctly installed. Use the JES commands
$T EXIT(7) and
$T EXIT(51) or $DMODULE(OPCAXIT7) and
$DMODULE(TWSXIT51) .
- Verify that the JES2 initialization data set contains a LOAD statement and an EXIT7 statement
for the HCL Workload Automation for Z version of JES2 exit
7 (OPCAXIT7).
Verify also that the JES2 initialization data set contains a LOAD
statement and an EXIT51 statement for the version of JES2 exit 51 (TWSXIT51)
- Verify that the exit has been added to a load module library reachable by JES2 and that JES2 has
been restarted since this was done.
|
B1 |
- Verify that the HCL Workload Automation for Z version
of the JES3 exit IATUX29 routine
has been correctly installed.
- Verify that the exit has been
added to a load-module library that
JES3 can access.
- Verify that JES3 has been restarted.
|
A2/B2 |
- Verify that the job for which no type 2 event was created
has
started to execute. A type 2 event will not be created for a job that
is flushed from the system because of JCL errors.
- Verify that
the IEFUJI exit has been correctly installed:
- Verify that the SMF parameter member SMFPRMnn in
the
SYS1.PARMLIB data set specifies that the IEFUJI exit should be called.
- Verify that the IEFUJI exit has not been disabled by an operator
command.
- Verify that the correct version of IEFUJI is active.
If SYS1.PARMLIB
defines LPALIB as a concatenation of several libraries, z/OS uses
the first IEFUJI module found.
- Verify that the library containing
this module was updated by
the HCL Workload Automation for Z version
of IEFUJI and that z/OS has
been IPLed since
the change was made.
|
A3S/B3S | If type 3J events
are also missing:
- Verify that the IEFACTRT exit has been correctly installed.
- Verify that the SMF parameter member SMFPRMnn in
the
SYS1.PARMLIB data set specifies that the IEFACTRT exit should be called.
- Verify that the IEFACTRT exit has not been disabled by an operator
command.
- Verify that the correct version of IEFACTRT is active.
If SYS1.PARMLIB
defines LPALIB as a concatenation of several libraries, z/OS uses
the first IEFACTRT module found.
- Verify that this library
was updated by the HCL Workload Automation for Z version
of
IEFACTRT and that z/OS has
been IPLed since the change was made.
If type 3J events are not missing, verify, in the EQQMLOG
data set, that the event writer has been requested to generate step-end
events. Step-end events are created only if the EWTROPTS statement
specifies STEPEVENTS(ALL) or STEPEVENTS(NZERO) or if the job step
abended. |
A3J/B3J |
If type 3S events are also missing, follow the procedures described for type 3S
events. |
A3P | If A1 events are also missing, follow the procedures described for A1 events. |
B3P |
- Verify that the HCL Workload Automation for Z version
of the JES3 exit IATUX19 routine
has been correctly installed.
- Verify that the exit has been
added to a load-module library that
JES3 can access.
- Verify that JES3 has been restarted.
|
A4/B4 |
- If you have specified PRINTEVENTS(NO) on the EWTROPTS initialization
statement, no type 4 events are created.
- Verify that JES has
printed the job for which no type 4 event
was created. Type 4 events will not be created for a job that creates
only held SYSOUT data sets.
- Verify that the IEFU83 exit has
been correctly installed:
- Verify that the SMF parameter member SMFPRMnn in
the
SYS1.PARMLIB data set specifies that the IEFU83 exit should be called.
- Verify that the IEFU83 exit has not been disabled by an operator
command.
- Verify that the correct version of IEFU83 is active.
If SYS1.PARMLIB
defines LPALIB as a concatenation of several libraries, z/OS uses
the first IEFU83 module found.
- Verify that the library containing
this module was updated by
the HCL Workload Automation for Z version
of IEFU83 and that z/OS has
been IPLed since
the change was made.
- For JES2 users (A4 event), ensure that
you have not specified
TYPE6=NO on the JOBCLASS and STCCLASS statements of the JES2 initialization
parameters.
|
A5 |
- Verify that JES2 has purged the job for which no A5 event
was
created.
- Ensure that you have not specified TYPE26=NO on the
JOBCLASS and
STCCLASS statements of the JES2 initialization parameters.
- If
A1 events are also missing, follow the procedures described
for A1 events.
|
B5 |
- Verify that JES3 has purged the job for which no B5 event
was
created.
- If B4 events are also missing, follow the procedures
described
for B4 events.
|