Enabling or Disabling Enterprise Replication Event Alarms

You can control which Enterprise Replication event alarms can be raised.

About this task

By default, Enterprise Replication event alarms are enabled, except most of the state change event alarms that are raised by specific cdr commands. You might want to enable state change event alarms to track which cdr commands are being run, but if you are setting up your replication system and running many cdr commands, the resulting large number of event alarms might affect system performance.

To change which Enterprise Replication event alarms are enabled, reset the values of the CDR_ENV configuration parameter for the CDR_ALARMS environment variable:

Procedure

  1. Add a new line or update the existing line for CDR_ENV CDR_ALARMS in the onconfig file. List all the Enterprise Replication event alarms that you want to be enabled.
  2. Restart the database server.

Example

The following example shows the CDR_ENV value in the onconfig file for the CDR_ALARMS environment variable with event alarm 49 enabled in addition to the default event alarms:
CDR_ENV CDR_ALARMS=30-39,47-50,71,73-75