The CONVERTVPS configuration parameter
The CONVERTVPS parameter limits the maximum number of VPs used for convert threads. This parameter limits the number of VPs that the onpload client uses so that onpload does not monopolize system resources.
Setting CONVERTVPS too large can cause performance degradation. Do not set more converter VPs than there are physical CPUs. If the number of CONVERTVPS exceeds the number of physical CPUs, system resources are consumed with no performance benefit.
On single-CPU computers, increasing this parameter has a negative effect on performance.
- Default value
- Single-processor computer: 1
Multiprocessor computer: 50 percent of physical CPUs
- Range of values
- From 1 to the number of physical CPUs
- See
- Assess information for loading or unloading external data