Manual test recording monitor
When you record a manual test script from Engineering Test Management, the manual test recording monitor is displayed.
HCL DevOps Test UI (Test UI), version 8.2.2 supports the manual test script recorder feature in Engineering Test Management. When Engineering Test Management is integrated with Test UI, you can record a manual test script in Engineering Test Management to test applications by using the Test UI recorder. The recorded test script is displayed in the Engineering Test Management editor and can be modified.
For more information about the manual test script recorder feature, see the Engineering Test Management Information Center.
Using the manual test recording monitor
When you initiate the recording of the manual test script from the Engineering Test Management computer, the Engineering Test Management interface minimizes and the manual test recording monitor is displayed on the Test UI computer. You can open the application-under-test (AUT) and record your actions.
When you stop recording, the monitor closes. In the Engineering Test Management browser, the Manual Steps list displays the recorded script actions.
The text in the recording monitor is similar to the sequence of commands that are recorded in the script. The text might contain additional information about errors that occurred during recording. The text is available while you have the monitor open. When you stop recording, the text is discarded and is not sent to Engineering Test Management. The text is not shown in the steps displayed in the Manual Steps list in Engineering Test Management. If you want to save the text, use the Copy Selected Text or Save Monitor Text As commands before you stop recording.
Manual test recording monitor toolbars
The recording monitor contains the Recording toolbar, which is the leftmost set of icons, and the Monitor toolbar, which is the rightmost set. The Recording toolbar is nested within the Monitor toolbar when you bring up the monitor. You can use the Recording toolbar to pause and stop recording, start applications, create a verification point, and insert items into your script. You can undock the Recording toolbar by clicking the Display Toolbar Only button . The monitor will float so that it only displays the Recording toolbar. To dock the Recording toolbar again and show the monitor, click the Display Monitor button . The display setting persists between recordings: if you only display the Recording toolbar, it is displayed this way the next time that you record.
Recording toolbar options
Button | Action |
---|---|
Stop Recording | Stop the recording. When recording stops, the monitor closes. In the Engineering Test Management browser, the Manual Steps list displays the recorded script actions. |
Pause Recording | Suspend recording. The monitor remains in view. |
Resume Recording | Continue recording. |
Start Application | Start the application that you want to test. The Start Application dialog opens, in which you choose an application. For more information about starting applications, see the Starting Your Test Applications or Start application dialog links at the bottom of this page. |
Insert Verification Point | Select an object and action. The Select an Object tab of the Verification Point Wizard is opens and displays the object selector tool from which you can select an object to start a verification point. You can insert data verification points or image verification points, but you cannot insert properties verification points, or get specific values for an object. For more information about selecting objects to create a verification point, see the Select an Object tab of the Verification Point Wizard link at the bottom of this page. For more information about verification points, see the related links at the bottom of this page.Note: You
can also use the Insert Verification
Point toolbar button itself to select an object. If you click the button and drag
it off the toolbar, the button becomes the object selector tool from
the Select an Object tab of the Verification
Point wizard. |
Insert Manual Step | Insert a manual step into the script. The Insert Manual Step dialog opens, in which you can provide the name of the step. |
Enable Image Capture | Enable the capturing of images during recording. When you enable this option, images are captured for the steps in the recording. If you do not want images to be captured, disable this option. |
Monitor toolbar options
Button | Action |
---|---|
Clear All Monitor Text | Clear all text from the monitor. To save the text before you clear it, use the Copy Selected Text button or the Save Monitor Text As button on the Monitor toolbar. Clearing the monitor text does not affect your recorded script. |
Save Monitor Text As | Save all the text in the monitor to a file. The Save As dialog opens, in which you can specify a file name and location. The Save Monitor Text As command selects and saves all the text into a .txt file. |
Monitor Message Preferences | The Monitor Options dialog opens, in which you can set preferences for the Recording Monitor Getting Started Help, message time stamp, the message filter level, and the message color. When you click this button, the Monitor options and the Message Text Color tabs open. These options are available on these tabs:
|