Known issues
You can find the known issues that are identified in this version of HCL DevOps Loop.
Known issues in DevOps Loop 2026.08 (2.0.2.1)
The following known issue is identified in this release:
| ID | Description |
|---|---|
| NEXUS00006751 | When you create a teamspace by
using an email ID that is exactly 12 characters long, the
operation might fail at the Measure phase because the MongoDB
5.9.2 package incorrectly treats the email value as an ObjectId.
In this case, the teamspace might be created in Velocity, but
the overall teamspace creation task does not complete
successfully. To work around this problem, you must avoid using email IDs that are exactly 12 characters long. |
| NEXUS00006817 | When you run tests through Deploy
in an HCL DevOps Loop in an air-gapped environment, the tests
might fail because the HCL DevOps Test Hub plugin version 4.3
does not work correctly with the Test Hub integration. To work around this problem, navigate to Deploy and update the HCL DevOps Test Hub plugin to version 5.0 to run Test Hub tests successfully. |
Known issues from earlier versions
The known issues identified in the earlier versions of DevOps Loop that are still applicable are as follows:
| ID | Description | Identified in version | Resolved in version |
|---|---|---|---|
| NEXUS00006323 |
When you install IBM DevOps Loop version 2.0.2 by using the default IBM entitled registry, DevOps Code dev containers that use the GitHub Copilot extension image or Trivy images might fail to start because the image registry is not configured correctly for the generated image specification. To work around this problem, you must update the
IMAGE_REGISTRY environment variable in
the devops-code-container-mgr deployment
after the installation is complete by following these
steps:
After the pod restrarts, you can create DevOps Code dev containers by using the GitHub Copilot extension image and Trivy images successfully. If you run the DevOps Loop installation script again, you must repeat this configuration change. Alternatively, before rerunning the installation, you must
update the
|
2.0.2 | 2.0.2.1 |
| NEXUS00006321 |
The demo installation scripts that are included with DevOps Loop 2.0.2 contain incorrect configuration values. As a result, the scripts might fail or produce unexpected results unless they are corrected before execution. To work around this problem, you must make the following
changes before running the demo installation scripts:
|
2.0.2 | 2.0.2.1 |
| NEXUS00005995 | When you upgrade the DevOps Loop
platform to version 2.0.2, existing 2.0.1 Learning Loops
continue to use the Ecological Payments sample application and
do not include the new Loop Genie tasks that are introduced in
version 2.0.2. The Upgrade Loop option is not available
for loops that were created in version 2.0.1. To work around this problem, you must create a new Learning Loop after upgrading to DevOps Loop 2.0.2 to use the CycleShop sample application and the latest Loop Genie tasks and tools. |
2.0.2 | |
| NEXUS00006310 | When teamspace creation fails, and
you select Cancel and Retry Later, the failed teamspace
is expected to appear in a red ribbon for later retry. Instead,
the page becomes unresponsive. To work around this problem, you must sign in with a different user account and create the Teamspace again. |
2.0.2 | 2.0.2.1 |
| NEXUS00006264 |
When you use Loop Genie to list the available loops, the request might fail because of a tool or domain metadata validation issue. As a result, Loop Genie might not display the available loops. Currently, there is no workaround for this problem. |
2.0.2 | |
| NEXUS00006216 |
When you use Loop Genie, the first request in a new session might fail with an internal server error because of API rate limiting. Although model validation completes successfully, the initial request might not be processed. To work around this problem, you must retry the request after a short interval. If the problem persists, you must start a new Loop Genie session and try the request again. |
2.0.2 | |
| NEXUS00006225 | When you use Loop Genie in a long
chat session, the conversation context might not be summarized
correctly as the model context window approaches its limit. As a
result, Loop Genie might not respond as expected or stop
processing requests. To work around this problem, you must start a new Loop Genie session and continue your conversation there. |
2.0.2 | |
| NEXUS00005427 | When a user is assigned an unsupported Keycloak group and
Measure/Release role combination, the system does not
display a clear authorization error. Instead, the user might
experience one of the following behaviors:
|
2.0.2 | |
| NEXUS00005067 | When you run the list test command, the response returns only
the count of projects instead of detailed test information such
as test names, IDs, or metadata. In some cases, the returned
data might also be inaccurate. Also, when you run a test prompt, the system might return a test asset file not found error even when the correct project ID and test name are provided, indicating an issue in locating or mapping the specified test file. Currently, there is no workaround for this problem. |
2.0.2 | |
| NEXUS00006206 | When you access the
/teamspaces or
/teamspaces/{id}/tasks API endpoints in an
IHD environment, you might experience slow response
times.Currently, there is no workaround for this problem. |
2.0.2 | |
| NEXUS00006316 | The Jenkins data is not available
in the Deployment by Environment Name
chart in Analytics Dashboards. Currently, there is no workaround for this problem. |
2.0.2 | 2.0.2.1 |
| NEXUS00004133 | When you use IBM watsonX, it might
not provide proper responses for multistep workflows. The issue
is currently observed only with workflows involving multiple
steps. Single-step workflows work as expected. To work around this problem, you must use IBM watsonX only for single-step workflows until the issue is resolved. |
2.0.0 | |
| NEXUS00003275 | When an administrator is added to a
loop by another administrator before logging into Measure for
the first time or before creating their own Loop, the
administrator cannot log in to Measure. To work around this problem, you must log in to Measure as another administrator (for example, the one who created the loop) and assign the global Product Administrator role to the administrator who cannot log in. |
1.0.3 |