Known issues in HCL AppScan 360°
Known issues in releases, and workarounds when applicable.
Known issues in AppScan 360° version 1.1.0
Known issues in AppScan Central Platform
- On some installations, regulatory and compliance reports generate without any issues.
Known issues in AppScan 360° Static Analysis
- Upgrading from AppScan 360° version 1.0.0
fails.
Error:
Deployment fails during upgrade due to failure to upgrade the version of RabbitMQ:Root causeFeature flags: classic_mirrored_queue_version: required feature flag not enabled! It must be enabled before upgrading RabbitMQ.
Failed to initialize feature flags registry: {disabled_required_feature_flag, classic_mirrored_queue_version}
Version 1.0.0 of AppScan 360° Static Analysis uses version 3.11.10 of RabbitMQ, which has since been upgraded. When an existing deployment of AppScan 360° Static Analysis version 1.0.0 is upgraded with AppScan 360° Static Analysis version 1.1.0 or later, the deployment fails until
featureflags
are enabled to allow upgrade of RabbitMQ.Solution
Before upgrading, manually enablefeatureflags
in the RabbitMQ pod:- Open a shell into the active and running RabbitMQ pod
- Run the command
rabbitmqctl enable_feature_flag all
. - Deploy AppScan 360° Static Analysis to upgrade .
Alternatively, uninstall AppScan 360° Static Analysis version1.0.0 and perform a fresh install of AppScan 360° Static Analysis version 1.1.0