Data set monitor

Read completed
Modification completed

Read completed

The event is triggered when a specified file has been read.

Property name Description Type Filtering allowed Required Multiple values allowed Multiple filter predicates allowed Wildcard allowed Length Default value
min max
Data set name The fully qualified path and data set name of the monitored data set. string           1      
Workstation The workstation for which the event is generated. string           1      

Modification completed

The event is triggered when a specified file remains unmodified in two consecutive monitoring cycles after a detected modification.

Property name Description Type Filtering allowed Required Multiple values allowed Multiple filter predicates allowed Wildcard allowed Length Default value
min max
Data set name The fully qualified path and data set name of the monitored data set. string           1      
Workstation The workstation for which the event is generated. string           1      



Wildcard allowed :
Supported wildcards are asterisk (*) and question mark (?)

Multiple values allowed :
You can specify multiple values for the property in a single filter predicate. The filter will be satisfied when one of the values is matched.

Multiple filter predicates allowed :
You can specify multiple filter predicates for the property. The event will match the event condition if all the predicates are satisfied.

Datetime :
Contains both date and time, you can specify in the filter either one or both values.