Upgrading the 8.x or 9.x model and installing new reports
Upgrading the 8.x or 9.x model and installing the new reports are the first steps that you must complete to upgrade your reports.
About this task
To upgrade the 8.x or 9.x model and install new reports, complete the following steps.
Procedure
- Browse to the Unica\ProductNameReportsPack\CognosN directory.
-
Copy the reports archive .zip file, such as Unica Reports for
Campaign.zip, to the directory where your Cognos®
deployment archives are saved.
The default location is the deployment directory under your Cognos® installation. The directory is specified in the Cognos® Configuration tool that is installed with the Cognos® Content Manager, for example: cognos\deployment.
In a distributed Cognos® environment, the directory is a located on the system that runs the Content Manager.
-
Copy the pre-upgrade version of the Unica Campaign model to a directory on the server where
Framework Manager is installed.
- If the Reports Pack installation directory and Framework Manager are on different servers, locate the upgraded cognos11\model directory under the Reports Pack installation directory.
- Copy the appropriate upgrade.xml files to the directory on the server where Framework Manager is installed.
- Copy the translation folder of the updated model (from the old model) to the directory on the server where Framework Manager is installed.
- If prompted for replacement, click Yes.
- Optional:
If you did not install your Unica product
to the default C:\Unica directory on Windows™, you must update the upgrade scripts.
Modify the file path in each script for every language that your users need, for example:
install_directory\ReportsPackCampaign\cognosN\CampaignModel\translations\L\translations.txt
L is the two-letter language indicator:
- fr
- de
- es
- it
- ja
- ko
- pt
- ru
- zh
- zh-tw
Edit the upgrade scripts for your product:
Unica Campaign
upgrade85to86.xml
upgrade86to90.xml
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
upgrade912to100.xml
Unica Deliver
upgrade86to90.xml
upgrade8604to91.xml
upgrade90to91.xml
upgrade91to911.xml
- To upgrade from version 9.1.0.x.0.0 (x >= 2)
- If you have not applied 9.1.0.2 Reports Feature Pack 1:
upgrade9102to911.xml
- If you applied 9.1.0.2 Reports Feature Pack 1:
upgrade910201to911.xml
- If you have not applied 9.1.0.2 Reports Feature Pack 1:
Unica Interact
upgrade85to86.xml
upgrade86to90.xml
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
Unica Campaign with Unica Plan
upgrade86to90.xml
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
Unica Plan
upgrade85to86.xml
- To upgrade from version 8.6 to version 9.0, depending on your database type:
- For DB2®:
upgrade86to90_DB2.xml
- For Oracle:
upgrade86to90_Oracle.xml
- For SQL server:
upgrade86to90_Sqlserver.xml
- For DB2®:
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
Unica Collaborate
upgrade86to90.xml
upgrade911to9112.xml
- Open Cognos® Connection.
- Select .
- Click the New Import button on the toolbar and import the reports folder.
- Open Cognos® Framework Manager and open the project for the version from which you are upgrading.
- Select .
-
Run the scripts from the new version of your product. All scripts are in the
ProductNameReportsPack\cognosN\ProductNameModel
directory under your Unica product
installation.
Note: You must consider the following points for the 8.x or 9.x version from which you are upgrading:
- You must run the preUpgrade_86_fromanyversion.xml script for upgrades from all versions except 8.6.
- You cannot upgrade reports from any source version to a destination version. For example, to upgrade reports from version 9.0.0 to version 9.1.1, you must first upgrade from version 9.0.0 to version 9.1, and then upgrade from version 9.1 to version 9.1.1.
- Only for Unica Deliver reports, you must upgrade from version 8.6.0.4 or later to 9.1 directly.
Unica Campaign
preUpgrade_86_fromanyversion.xml
upgrade85to86.xml
upgrade86to90.xml
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
upgrade912to100.xml
upgradeto12103.xml
Unica Deliver
upgrade86to90.xml
upgrade8604to91.xml
upgrade90to91.xml
upgrade91to911.xml
- To upgrade from version 9.1.0.x.0.0 (x >= 2)
- If you have not applied 9.1.0.2 Reports Feature Pack 1:
upgrade9102to911.xml
- If you applied 9.1.0.2 Reports Feature Pack 1:
upgrade910201to911.xml
- If you have not applied 9.1.0.2 Reports Feature Pack 1:
Unica Interact
preUpgrade_86_fromanyversion.xml
upgrade85to86.xml
upgrade86to90.xml
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
upgrade912to9121.xml
Unica Campaign with Unica Plan
upgrade86to90.xml
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
Unica Plan
upgrade85to86.xml
- To upgrade from version 8.6 to version 9.0, depending on your database type:
- For DB2®:
upgrade86to90_DB2.xml
- For Oracle:
upgrade86to90_Oracle.xml
- For SQL server:
upgrade86to90_Sqlserver.xml
- For DB2®:
upgrade90to91.xml
upgrade91to911.xml
upgrade911to9112.xml
upgradeto12103.xml
Unica Collaborate
upgrade86to90.xml
upgrade911to9112.xml
-
For Unica Deliver only: To upgrade Unica Deliver reports, complete the following steps:
Note: If your database is DB2®, change the statement termination character from ; (semicolon) to ! (exclamation point).
- Publish the package to the Cognos® content store.
- For all Unica products,
complete the following steps:
- Browse to .
- Select the appropriate reports package according to your product and click OK.
- Complete prompts on the report as necessary.
- After the report is validated, click Close in the Validation Response window.
- Run a report to test your upgrade.
Note: You must publish the package after running model upgrade scripts.