Setting thread pool values
Set the thread pool values for an IBM® Sametime® Gateway server and the SIP container to improve performance between the SIP container and the Sametime Gateway application server layer. By using a thread pool, server components can reuse existing threads, which helps improve performance by reducing the overhead of creating new threads at run time.
Procedure
- From Integrated Solutions Console, click Thread Pools. , and then in the "Additional Properties" section, click
- Click New, and then type a name of your choice, such as STGWPool, in the Name field.
- Type
30
in the Minimum Size field. - Type
30
in the Maximum Size field. - Keep the default value of
5000
for thread inactivity. - Click OK, and click Save to save changes to the master configuration.
- Click , and in the "Container Settings" section, select .
- From the list of Thread pool, select the thread pool that you just created.
- Set Maximum dispatch queue size to
5000
. - Keep the default values of
120000
for Maximum application sessions, and5000
for Maximum messages per averaging period. - Click OK, and click Save to save changes to the master configuration.
- If Sametime Gateway is clustered, repeat the preceding steps for each node of the cluster.