Configuring the SIP container for Microsoft Office Communications Server/Lync Server chats
The SIP container writes Address objects without using the open and close angle brackets (< and >) if there is no display name. The omission of these brackets means that Sametime® users cannot initiate a chat with a Microsoft™ Office Communication Server/Lync Server (Lync/OCS) user. To resolve this problem, add a SIP container custom property.
About this task
force.name.addr
custom property
to force the inclusion of brackets around the URI section, even if
the display name is empty. Procedure
- Log in to the WebSphere® Integrated Services Console as a Sametime Gateway administrator.
- Click .
- In the list of WebSphere Application Servers, click RTCGWServer.
- In the Container settings section, click SIP Container Settings and then click SIP container.
- In the Additional Properties section, click Custom properties.
- Click New and enter information for the new custom property:
- In the Name field, enter force.name.addr.
- In the Value field, enter true.
- Click OK, and then click Save in the "Messages" box at the beginning of the page.
- Restart the RTCGWServer.