Defect HC-12297
Full build index, preprocessing fails on table TI_CATGPENREL_0
Software
Customer case | Applies to | Corrected in |
---|---|---|
CS0254768 | V9.1.7.0 | 9.1.8.0 |
Observed behavior
During a full build of the index, pre-processing fails on table TI_CATGPENREL_0
Expected behavior
The data import pre-processing operation should run cleanly.
Resolution
The TI_CATGPENREL_#INDEX_SCOPE_TAG template in wc-dataimport-preprocess-direct-parent-catentry.xml file was updated to cast the SEQUENCE fields as VARCHAR(32672) to avoid the error situation.