Capacity scan return codes
If the capacity scan fails, an error code that indicates why the scan failed is returned. Check what is the possible cause of scan failure that is indicated by each code and how to solve the problem.
Locating the return codes
If the capacity scan fails, first check whether the return code is related to the scanner, or to running the checkCapacityScanOutput.vbs script. If the log refers to the script, the return code is specific for the script. It indicates that the capacity scan results are incomplete. The problem is usually solved after the next scan or after the upgrade of the scanner to the latest version.
- The scanner error codes for capacity scan are written in the BigFix client logs. The logs are stored in the following locations:
/var/opt/BESClient/__BESData/__Global/Logs
C:\Program Files (x86)\BigFix Enterprise\BESClient\__BESData\__Global\Logs
- To check the error codes that are related to running the checkCapacityScanOutput.vbs script, check the Run Capacity Scan and Upload Results action in the BigFix console. On the Computers tab, identify the computer on which the action failed by checking its status. Double-click this computer. The error code is written in execution details.
Capacity scan return codes
Return code | Possible cause and solutions |
---|---|
0 | No errors. |
1 |
Wrong arguments were used during the capacity scan. Ensure that the capacity scan is triggered with an official fixlet. |
2 |
The scan configuration file is corrupted. For more information, refer to Update the fixlet site. If you have fapolicyd (File Access Policy Daemon) installed, then you need to whitelist the capacity scanner. For more information, refer to Whitelisting scanner. |
5 | The user that runs the scan does not have read permission to the scanner configuration file. Ensure that the BigFix client is running as SYSTEM user on Windows, or root for other operating systems. |
8 | Scanner internal error occurred. Gather scanner logs and contact HCL
Support. By default, the log files are in the following directory:
|
11 | Scan output file or directory is read only.
Ensure that the scan output file or directory is writable for
the user that is running the BigFix client. By
default, the directory is:
|
13 | The scanner configuration file was not found. Reinstall or update the scanner. |
18 | One of the scanner files could not be open.
Ensure that the administrator or root of the computer on which
the problem occurred has the read and write permissions to the
following files:
|
21 | The scanner configuration file is corrupted. Reinstall or upgrade the scanner. |
49 | The user that runs the scan does not have the
read permission to the scanner properties file
Cit.properties. Ensure that the
administrator or root of the computer on which the problem
occurred has the read permissions to this file. By default, the
file is in the following directory:
|
54 | The scan file cannot be compressed. Ensure
that the administrator or root of the computer on which the
problem occurred has the read and write permissions to the
following directory:
|
Return codes greater than 128

return code - 128 = operating system signal
To identify the issue, check the meaning of the signal in the operating system documentation.
Return code | Signal | Possible cause and solution |
---|---|---|
134 | 6 - SIGABRT | There might not be enough memory available for the process to work. Increase the memory limit
for this process by changing ulimit for data seg size : ulimit -d .
If the problem persists, contact BigFix Support. |
138 | 10 - SIGBUS | There is not enough disk space on the computer. Free some disk space. If the problem persists, ensure that you use the latest version of the scanner. |
139 | 11 - SIGSEGV | There might not be enough memory available for the process to work. Increase the memory limit
for this process by changing ulimit for data seg size : ulimit -d .
If the problem persists, contact BigFix Support. |
Return codes related to the checkCapacityScanOutput.vbs script
Return code | Possible cause
|
Systems other than Windows |
Solution |
---|---|---|---|
1 | A general VBS script error. The Windows Script Host could be disabled. | n/a | Enable Windows Script Host. |
2 | ComponentID is missing the
SerialNumber attribute in capacity scan
output file. |
Capacity scan output file is missing the
PhysicalProcessor section. |
Update the scanner to the latest version. For more information, see: Installing the scanner |
3 | SerialNumber attribute in the capacity scan
output file does not contain any value. |
Capacity scan output file is missing the
OperatingSystem section. |
|
4 | Capacity scan output file is missing the
PhysicalProcessor section. |
Capacity scan output file is missing the
Lpar section. |
|
5 | Capacity scan output file is missing the
OperatingSystem section. |
n/a | |
6 | Capacity scan output file is missing the
Lpar section. |
n/a | |
7 | Capacity scan output file is missing the
ComponentID section. |
Capacity scan output file is missing the